1、 ETSI TS 102 873 V1.1.1 (2010-10)Technical Specification Access, Terminals, Transmission and Multiplexing (ATTM); Optical External Network Testing InterfaceETSI ETSI TS 102 873 V1.1.1 (2010-10)2Reference DTS/ATTM-02010 Keywords fibre, interface, optical, testing ETSI 650 Route des Lucioles F-06921 S
2、ophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice Individual copies of the present document can be downloaded from: http:/www.etsi.org
3、 The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI
4、 printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http:/portal.etsi.
5、org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http:/portal.etsi.org/chaircor/ETSI_support.asp Copyright Notification No part may be reproduced except as authorized by written permission. The copyright and the foregoing
6、 restriction extend to reproduction in all media. European Telecommunications Standards Institute 2010. All rights reserved. DECTTM, PLUGTESTSTM, UMTSTM, TIPHONTM, the TIPHON logo and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members. 3GPPTM is a Trade Mark of ETSI regi
7、stered for the benefit of its Members and of the 3GPP Organizational Partners. LTE is a Trade Mark of ETSI currently being registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM and the GSM logo are Trade Marks registered and owned by the GSM Association. ETSI ETSI TS
8、 102 873 V1.1.1 (2010-10)3Contents Intellectual Property Rights 4g3Foreword . 4g3Introduction 4g31 Scope 5g32 References 5g32.1 Normative references . 5g32.2 Informative references 7g33 Definitions and abbreviations . 7g33.1 Definitions 7g33.2 Abbreviations . 7g34 Functional characteristics . 7g34.1
9、 Optical ENTI location 8g34.2 Optical termination . 8g34.2.1 Pre-terminated connectors with pigtails 9g34.2.2 Field mountable, pre-terminated connectors with fibre stub . 9g34.2.3 Pre-ferruled cables 9g34.2.4 Pre-terminated solution . 9g34.2.5 Field mountable connectors 10g34.3 Optical measuring and
10、 testing features . 10g34.4 Connection to ONT 10g34.5 Optical ENTI outlet 10g34.6 Opening and prevention of damaging of outlet and fibre . 11g35 Particular characteristics. 11g35.1 Environmental conditions . 11g35.2 Laser safety 11g35.3 Installation and dimensioning. 11g35.4 Fibre types 11g35.5 Fibr
11、e splices 11g35.6 Fibre optic connectors 12g35.7 Optical cables to be installed in ENTI outlet 12g35.8 Measuring or monitoring of the optical line . 13g35.9 Measurements with OTDR . 13g35.10 Measurements with LSPM 13g35.11 Operations 13g35.12 Miscellaneous . 14g35.13 Documentation . 14g35.14 Recycli
12、ng 14g36 Testing 15g3Annex A (informative): Bibliography . 16g3History 17g3ETSI ETSI TS 102 873 V1.1.1 (2010-10)4Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is
13、 publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the
14、 ETSI Web server (http:/webapp.etsi.org/IPR/home.asp). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which
15、are, or may be, or may become, essential to the present document. Foreword This Technical Specification (TS) has been produced by ETSI Technical Committee Access, Terminals, Transmission and Multiplexing (ATTM). Introduction An Optical External Network Testing Interface (ENTI) is a passive element t
16、hat sits at the boundary between the Access Network (AN) and the end user (subscribers) in-house FITH Network. From a certain point of view ENTI can be regarded as a testing demarcation point between the access network and the wiring at the customer premises. External Network Testing Interface ENTI
17、defines the point for testing the operators network while isolated from the customers home wiring. ETSI ETSI TS 102 873 V1.1.1 (2010-10)51 Scope The present document defines the functional and technical characteristics applicable to the Optical External Network Testing Interface (ENTI) terminated wi
18、th Singlemode fibre which provides testing capability at the demarcation point between the line of the FTTH operators network and the customers cabling inside the house. The present document describes optical ENTI for new homes. An optical ENTI is positioned in a distribution space. It is connected
19、to an ONT by an optical terminated cord. The home cabling is not considered in the present document. The present document specifies the functional characteristics and performance requirements for the optical ENTI within the subscriber premises and for the needs of the FTTH optical access network. 2
20、References References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the reference document (including any amendments) applies
21、. Referenced documents which are not found to be publicly available in the expected location might be found at http:/docbox.etsi.org/Reference. NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee their long term validity. 2.1 Normative refer
22、ences The following referenced documents are necessary for the application of the present document. 1 CENELEC EN 50174-2: “Information technology - Cabling installation - Part 2: Installation planning and practices inside buildings“. 2 CENELEC EN 50377 series: “Connector sets and interconnect compon
23、ents to be used in optical fibre communication systems - Product specifications“. 3 CENELEC EN 60793-2-50: “Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres“. 4 CENELEC EN 60794-2: “Optical fibre cables - Part 2: Indoor optical fibre cables
24、- Sectional specification“. 5 CENELEC EN 60794-2-20: “Optical fibre cables - Part 2-20: Indoor cables - Family specification for multi-fibre optical distribution cables“. 6 CENELEC EN 60794-2-50: “Optical fibre cables - Part 2-50: Indoor cables - Family specification for simplex and duplex cables fo
25、r use in terminated cable assemblies“. 7 CENELEC EN 60794-3-10: “Optical fibre cables - Part 3-10: Outdoor cables - Family specification for duct, directly buried and lashed aerial optical telecommunication cables“. 8 CENELEC EN 60794-3-11: “Optical fibre cables - Part 3-11: Outdoor cables - Product
26、 specification for duct, directly buried and lashed aerial single-mode optical fibre telecommunication cables“. 9 CENELEC EN 60794-3-20: “Optical fibre cables - Part 3-20: Outdoor cables - Family specification for self-supporting aerial telecommunication cables“. ETSI ETSI TS 102 873 V1.1.1 (2010-10
27、)610 CENELEC EN 61753-131-3: “Fibre optic interconnecting devices and passive components - Performance standard - Part 131-3: Single-mode mechanical fibre splice for category U - Uncontrolled environment“. 11 ETSI TS 100 783: “Transmission and Multiplexing (TM); Passive optical components; Fibre opt
28、ic fusion splices for single-mode optical fibre transmission systems for indoor and outdoor applications; Common requirements and conformance testing“. 12 ETSI ETS 300 019-1-3: “Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-3: C
29、lassification of environmental conditions; Stationary use at weatherprotected locations“. 13 CENELEC EN 61756-1: “Fibre optic interconnecting devices and passive components - Interface standard for fibre management systems - Part 1: General and guidance“. 14 CENELEC EN 61754: “Fibre optic interconne
30、cting devices and passive components - Fibre optic connector interfaces“. 15 CENELEC EN 61755: “Fibre optic interconnecting devices and passive components - Fibre optic connector optical interfaces“. 16 IEC 60825-1: “Safety of laser products - Part 1: Equipment classification and requirements “. 17
31、IEC 60825-2: “Safety of laser products - Part 2: Safety of optical fibre communication systems (OFCS)“. 18 CENELEC EN 61280-4-2: “Fibre optic communication subsystem basic test procedures - Part 4-2: Fibre optic cable plant - Single-mode fibre optic cable plant attenuation“. 19 IEC 60950-1: “ Inform
32、ation technology equipment - Safety - Part 1: General requirements“. 20 IEC 61300-3-1: “Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination“. 21 IEC 60529: “Degrees of protection provided by
33、 enclosures (IP Code)“. 22 IEC 61300-2-27: “Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-27: Tests - Dust - Laminar flow“. 23 IEC 61300-2-26: Fibre optic interconnecting devices and passive components - Basic test and measurement procedu
34、res - Part 2-26: Tests - Salt mist“. 24 IEC 61753-101-2: “Fibre optic interconnecting devices and passive components performance standard - Part 101-2: Fibre management systems for Category C - Controlled environment“. 25 IEC 61300-2-12: “Fibre optic interconnecting devices and passive components -
35、Basic test and measurement procedures - Part 2-12: Tests - Impact“. 26 IEC 61300-2-4: “Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention“. 27 IEC 61300-2-42: “Fibre optic interconnecting devices and passive co
36、mponents - Basic test and measurement procedures - Part 2-42: Tests - Static side load for connectors“. 28 IEC 61300-2-6: “Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-6: Tests - Tensile strength of coupling mechanism“. 29 IEC 61300-2-2:
37、 “Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-2: Tests - Mating durability“. 30 IEC 61300-2-9: “Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-9: Tests - Shock“. 31 CENELEC EN
38、 60794-3: “Optical fibre cables - Part 3: Sectional specification - Outdoor cables“. ETSI ETSI TS 102 873 V1.1.1 (2010-10)732 IEC 61300-2-33: “Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-33: Tests - Assembly and disassembly of fibre opt
39、ic closures“. 33 IEC 61300-2-5: “Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion“. 2.2 Informative references The following referenced documents are not necessary for the application of the present document but they assis
40、t the user with regard to a particular subject area. Not applicable. 3 Definitions and abbreviations 3.1 Definitions For the purposes of the present document, the following terms and definitions apply: cable element: cable subassembly comprising one or more optical fibres inside a common covering EX
41、AMPLE: Tube. distribution space: space in the customer premise enclosing physical telecommunication interfaces, normally lockable hybrid patchcord: optical patchcord or work area cord with different fibre optic connector on each end 3.2 Abbreviations For the purposes of the present document, the fol
42、lowing abbreviations apply: APC Angled Physical Contact EN European Norm ENTI External Network Testing Interface FITH Fibre In The Home FTTH Fibre To The Home LSPM Laser Source Power Meter ONT Optical Network Terminal OTDR Optical Time Domain Reflectometer PC Physical Contact 4 Functional characteri
43、stics Optical ENTI is the physical point at which a subscriber is provided with access to an optical communications network. An ENTI device will be installed for each subscriber. Optical ENTI unit is enclosed in a durable housing appropriate for use in a distribution space and constitutes integral p
44、art of the subscriber line of the operators network. The ENTI: is a part of the demarcation point; is a measuring and testing point; will allow isolation of customers in-house cabling from the operators network; ETSI ETSI TS 102 873 V1.1.1 (2010-10)8 will encompass laser safety; will allow optical c
45、onnectivity. Additional functional characteristics of the ENTI are: fibre management system within housing (tray, splice holder, etc.); fibre overlength for consecutive splicing as well as management of fibre overlengths. 4.1 Optical ENTI location ENTI, as it is described in the present document for
46、 new homes, must be located inside a distribution space (collocated near the home distributor as depicted in figure 1). Optical ENTI characteristics for use outside a distribution space in existing homes are not considered in the present document. Figure 1: Optical ENTI within a distribution space 4
47、.2 Optical termination Optical termination is accomplished by means of fibre optic connector plug and adaptor. The termination of the fibre is a connector plug. The connector plug can be pre-terminated (pre-terminated cable) at the manufacturers plant or by means of field mountable connector system.
48、 Connector plug is positioned in the adaptor. Adaptor is a part of the optical ENTI outlet and it is an integral part of the optical termination. Optical termination has two connection functions: connection to the ONT; connection to the measuring equipment. By plugging another connector into the ada
49、ptor optical connection interface is accomplished. ETSI ETSI TS 102 873 V1.1.1 (2010-10)9The requirements on optical connection interface are: mechanical; optical. The mechanical requirements shall be according to CENELEC EN 61754 14 series and optical performance according to CENELEC EN 61755 15 series. Optical connectors may be PC or APC (type SC, LC, LX.5 etc.) 4.2.1 Pre-terminated connectors with pigtails Pre-terminated connector with pigtail is a product configuration cons