ETSI TS 102 874-5-2012 Access Terminals Transmission and Multiplexing (ATTM) External Common Power Supply for Customer Premises Network and Access Equipment Part 5 CPS Type 2 c imp.pdf

上传人:ownview251 文档编号:739666 上传时间:2019-01-11 格式:PDF 页数:42 大小:223.16KB
下载 相关 举报
ETSI TS 102 874-5-2012 Access Terminals Transmission and Multiplexing (ATTM) External Common Power Supply for Customer Premises Network and Access Equipment Part 5 CPS Type 2 c imp.pdf_第1页
第1页 / 共42页
ETSI TS 102 874-5-2012 Access Terminals Transmission and Multiplexing (ATTM) External Common Power Supply for Customer Premises Network and Access Equipment Part 5 CPS Type 2 c imp.pdf_第2页
第2页 / 共42页
ETSI TS 102 874-5-2012 Access Terminals Transmission and Multiplexing (ATTM) External Common Power Supply for Customer Premises Network and Access Equipment Part 5 CPS Type 2 c imp.pdf_第3页
第3页 / 共42页
ETSI TS 102 874-5-2012 Access Terminals Transmission and Multiplexing (ATTM) External Common Power Supply for Customer Premises Network and Access Equipment Part 5 CPS Type 2 c imp.pdf_第4页
第4页 / 共42页
ETSI TS 102 874-5-2012 Access Terminals Transmission and Multiplexing (ATTM) External Common Power Supply for Customer Premises Network and Access Equipment Part 5 CPS Type 2 c imp.pdf_第5页
第5页 / 共42页
点击查看更多>>
资源描述

1、 ETSI TS 102 874-5 V1.2.1 (2012-03) Access, Terminals, Transmission and Multiplexing (ATTM); External Common Power Supply for Customer Premises Network and Access Equipment; Part 5: CPS Type 2.c implementation details Technical Specification ETSI ETSI TS 102 874-5 V1.2.1 (2012-03)2Reference RTS/ATTM

2、-02015 Keywords connector, customer premises networks, EMC, LAN, power supply, terminal ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture d

3、e Grasse (06) N 7803/88 Important notice Individual copies of the present document can be downloaded from: http:/www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions,

4、 the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revisi

5、on or change of status. Information on the current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http:/portal.etsi.org/chaircor/ETSI_support.asp

6、 Copyright Notification No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2012. All rights reserved. DECTTM, PLUGTESTSTM, UMTSTMand the ETSI logo are T

7、rade Marks of ETSI registered for the benefit of its Members. 3GPPTM and LTE are Trade Marks of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM and the GSM logo are Trade Marks registered and owned by the GSM Association. ETSI ETSI TS 102 874-5 V1.2.1 (201

8、2-03)3Contents Intellectual Property Rights 7g3Foreword . 7g3Introduction 7g31 Scope 9g32 References 9g32.1 Normative references . 9g32.2 Informative references 11g33 Definitions and abbreviations . 11g33.1 Definitions 11g33.2 Abbreviations . 12g34 Electrical Specifications . 12g34.1 Input Requireme

9、nts 12g34.2 Output Requirement . 13g34.2.1 Output Voltage, Current And Ripple 13g34.2.2 Short Circuit Protection And Over Current Protection . 13g34.2.3 Output Over Voltage Protection . 13g34.3 Performance Requirement 13g34.3.1 Efficiency 13g34.3.2 Turn On Delay Time . 14g34.3.3 Hold-up Time 14g34.3

10、.4 Brown-out and recovery . 14g34.3.5 Dynamic Load 14g34.3.6 Max Open Circuit Voltage 14g34.3.7 Overshoot at turn on/Turn off . 14g34.3.8 Output transient response/Transient load slew . 15g34.3.9 Rise time . 15g35 Operational, Storage and Transportation Requirements. 15g35.1 Temperature And Humidity

11、 . 15g36 EMC, safety and Environmental requirements 15g36.1 Product EMC 15g36.2 Product Safety 16g36.3 Environmental and Eco-Design Requirements . 16g37 Reliability . 17g37.1 Burn-in . 17g37.2 MTBF Calculation 17g38 Mechanical Specification . 17g38.1 AC plug 17g38.2 DC cord 17g38.3 Label specificati

12、on . 17g3Annex A (informative): Details on Test Procedures 18g3A.0 Overview of Tests 18g3A.0.1 Test Equipment 18g3A.1 Performance test . 19g3A.1.1 Test purpose . 19g3A.1.2 Test Condition 19g3A.1.3 Test Criteria 19g3A.1.4 Results report examples 19g3A.2 Switcher Loop Stability Test 21g3ETSI ETSI TS 1

13、02 874-5 V1.2.1 (2012-03)4A.2.1 Test Purpose . 21g3A.2.2 Test Condition 21g3A.2.3 Test Criteria 22g3A.2.4 Results report example . 22g3A.3 Life test . 22g3A.3.1 Test Purpose . 22g3A.3.2 Test Condition 22g3A.3.3 Test Criteria 22g3A.3.4 Results report example . 23g3A.4 Dynamic load switching test 23g3

14、A.4.1 Test Purpose . 23g3A.4.2 Test Condition 23g3A.4.3 Test Criteria 23g3A.4.4 Results report example . 24g3A.5 Output trans response-load slew and step 24g3A.5.1 Test Purpose . 24g3A.5.2 Test Condition 24g3A.5.3 Test Criteria 24g3A.5.4 Results report example . 24g3A.6 AC input inrush current test

15、. 24g3A.6.1 Test Purpose . 24g3A.6.2 Test Condition 24g3A.6.3 Test Criteria 25g3A.6.4 Results report example . 25g3A.7 Turn on delay test . 25g3A.7.1 Test Purpose . 25g3A.7.2 Test Condition 25g3A.7.3 Test Criteria 25g3A.7.4 Results report example . 25g3A.8 Output hold-up time test . 26g3A.8.1 Test P

16、urpose . 26g3A.8.2 Test Condition 26g3A.8.3 Test Criteria 26g3A.8.4 Results report example . 26g3A.9 Rise time and overshoot test . 26g3A.9.1 Test Purpose . 26g3A.9.2 Test Condition 26g3A.9.3 Test Criteria 27g3A.9.4 Results report example . 27g3A.10 Output transient response deviation test . 27g3A.1

17、0.1 Test Purpose . 27g3A.10.2 Test Condition 27g3A.10.3 Test Criteria 27g3A.10.4 Results report example . 28g3A.11 Dynamic load test . 28g3A.11.1 Test Purpose . 28g3A.11.2 Test Condition 28g3A.11.3 Test Criteria 28g3A.11.4 Results report example . 28g3A.12 Brown out and recovery test . 29g3A.12.1 Te

18、st Purpose . 29g3A.12.2 Test Condition 29g3A.12.3 Test Criteria 29g3A.12.4 Results report example . 29g3A.13 Temperature storage test 29g3ETSI ETSI TS 102 874-5 V1.2.1 (2012-03)5A.13.1 Test Purpose . 29g3A.13.2 Test Condition 29g3A.13.3 Test Criteria 30g3A.13.4 Results report example . 30g3A.14 Humi

19、dity storage test 30g3A.14.1 Test Purpose . 30g3A.14.2 Test Condition 30g3A.14.3 Test Criteria 31g3A.14.4 Results report example . 31g3A.15 Power cycle test 31g3A.15.1 Test Purpose . 31g3A.15.2 Test Condition 31g3A.15.3 Test Criteria 31g3A.15.4 Results report example . 31g3A.16 Shipping, single drop

20、, vibration test . 31g3A.16.1 Test Purpose . 31g3A.16.2 Test Condition 31g3A.16.3 Test Criteria 32g3A.16.4 Results report example . 33g3A.17 Short circuit protection test 33g3A.17.1 Test Purpose . 33g3A.17.2 Test Condition 33g3A.17.3 Test Criteria 33g3A.17.4 Results report example . 33g3A.18 Over vo

21、ltage protection test . 34g3A.18.1 Test Purpose . 34g3A.18.2 Test Condition 34g3A.18.3 Test Criteria 34g3A.18.4 Results report example . 34g3A.19 Over current protection test 34g3A.19.1 Test Purpose . 34g3A.19.2 Test Condition 34g3A.19.3 Test Criteria 35g3A.19.4 Results report example . 35g3A.20 Con

22、struction, Appearance and Weight . 35g3A.20.1 Test purpose . 35g3A.20.2 Test Condition 35g3A.20.3 Test Criteria 35g3A.20.4 Results report example . 36g3A.21 Safety tests 36g3A.22 DC cord set and plug test . 36g3A.22.1 Test Purpose . 36g3A.22.2 Test Condition 1 . 36g3A.22.3 Test Condition 2 . 36g3A.2

23、2.4 Test Criteria 37g3A.22.5 Results report example . 37g3A.23 Energy efficiency test . 37g3A.23.1 Test Purpose . 37g3A.23.2 Test Condition 37g3A.23.3 Test Criteria 37g3A.23.4 Results report example . 38g3A.24 Capacitive load test 38g3A.24.1 Test Purpose . 38g3A.24.2 Test Condition 38g3A.24.3 Test C

24、riteria 38g3ETSI ETSI TS 102 874-5 V1.2.1 (2012-03)6A.24.4 Results report example . 38g3A.25 Maximum open circuit voltage test 39g3A.25.1 Test Purpose . 39g3A.25.2 Test Condition 39g3A.25.3 Test Criteria 39g3A.25.4 Results report example . 39g3A.26 EMC tests . 39g3Annex B (informative): PLT filters

25、to limit interference and improve coexistence . 40g3B.1 Testing immunity of PLT equipment to CPS disturbances 40g3B.1.1 Test Purpose . 41g3B.1.2 Test Condition 41g3B.1.3 Test Criteria 41g3B.1.4 Results report example . 41g3History 42g3ETSI ETSI TS 102 874-5 V1.2.1 (2012-03)7Intellectual Property Rig

26、hts IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential

27、, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/ipr.etsi.org). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by

28、ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This Technical Specification (TS) has been produced by ETSI Technical Committee

29、 Access, Terminals, Transmission and Multiplexing (ATTM). The present document is part 5 of a multi-part deliverable covering the External Common Power Supply (CPS) for Customer Premises Network and Access Equipment, as identified below: ES 202 874-1: “Functional requirements“; TS 102 874-2: “Integr

30、ated Broadband Cable and Television Networks“; TS 102 874-3: “CPS Type 1 implementation details“; TS 102 874-4: “CPS Type 2.b implementation details“; TS 102 874-5: “CPS Type 2.c implementation details“; TS 102 874-6: “CPS Type 2.d implementation details“. Introduction The intended applications of t

31、hese CPS categories are specified in ES 202 874-1 i.1. Table 1 summarises the structure of the series. Table 1: Multi-part deliverable structure CPS category Functional requirements Implementation aspects Type 1: 5 V, 2 A ES 202 874-1 i.1 TS 102 874-3 i.3 Type 2.a: 12 V, 1 A TS 102 874-2 i.2 Type 2.

32、b: 12 V, 2 A TS 102 874-4 i.4 Type 2.c: 12 V, 5 A TS 102 874-5 (the present document) Type 2.d: 12 V, 3,2 A TS 102 874-6 i.5 The present document addresses the implementation details of the External Common Power Supply (CPS) for Customer Premises Network and Access Equipment - Type 2.c, rated to a m

33、aximum of 12 V dc and a maximum current of 5 A for use with customer network devices with power needs up to 60 W. Other methods for providing power to end devices are not in the scope of the document (e.g. Power Over Ethernet, power on USB, etc.). Test are specified to verify the compliance of the e

34、xternal power supply against the requirements given by the present document. ETSI ETSI TS 102 874-5 V1.2.1 (2012-03)8The present document specifies design requirements and tests to ensure compliance of the CPS as well as reference to relevant European Directives including power efficiency on-load an

35、d no-load requirements given by European Commission Regulation No 278/2009 1 of 6 April 2009. ETSI ETSI TS 102 874-5 V1.2.1 (2012-03)91 Scope The present document describes the specification for a high performance External Power Supply Unit for powering the Customer Premises Equipment to a maximum v

36、oltage rating of 12 V dc. The specifications define the input, output characteristics and performance requirements for a switching mode AC to DC CPS rated to a maximum 12 V dc, and maximum 5 A. The present document also specifies tests to verify the compliance of the external CPS. Disclaimer: The pr

37、esent document does not guarantee compliance to legal directives or regulations. Details about these aspects can be found on the following links: http:/ec.europa.eu/enterprise/sectors/electrical/index_en.htm http:/ec.europa.eu/enterprise/sectors/electrical/documents/lvd/standardisation/index_en.htm

38、http:/ec.europa.eu/enterprise/sectors/electrical/documents/emc/standardisation/index_en.htm NOTE: Examples of documents to be considered are CE Marking 93/68/EEC 13, LVD Low Voltage Directive 2006/95/EC 12, EMC Directive 2004/108/EC 14; for Ecodesign aspects: RoHS (Restriction of Hazardous Substance

39、s) European Directive 2011/65/EC 8 8 June 2011 and WEEE Management Regulations (Waste Electrical and Electronic Equipment) European Directives 2002/96/EC 27 January 2003 and amendments 9. 2 References References are either specific (identified by date of publication and/or edition number or version

40、number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the reference document (including any amendments) applies. Referenced documents which are not found to be publicly available in the expected location might be found at

41、 http:/docbox.etsi.org/Reference. NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee their long term validity. 2.1 Normative references The following referenced documents are necessary for the application of the present document. 1 Commissi

42、on Regulation (EC) No 278/2009 of 6 April 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for no-load condition electric power consumption and average active efficiency of external power supplies. 2 CENELEC EN 55022:2006 + Am

43、endment 1: 2007: “Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement“. 3 CISPR 22: “Information technology equipment - Radio disturbance characteristics - Limits and methods of measurements“. 4 CENELEC EN 61000-3-2: “Electromagnetic compatibility

44、 (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current = 16 A per phase)“. 5 CENELEC EN 61000-4-2: “Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test“. 6 CENELEC EN 61000-4-5: “Electromagneti

45、c compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test“. ETSI ETSI TS 102 874-5 V1.2.1 (2012-03)107 CENELEC EN 61000-4-11: “Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variatio

46、ns immunity tests“. 8 Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (recast). 9 Directive 2002/96/EC of the European Parliament and of the Council of 27 January 20

47、03 on waste electrical and electronic equipment (WEEE), (and amendments). 10 CENELEC EN 60950-1: “Information technology equipment - Safety - Part 1: General requirements“. 11 CENELEC EN 50075: “Flat non-rewirable two-pole plugs, 2,5 A 250 V, with cord, for the connection of class II-equipment for h

48、ousehold and similar purposes“. 12 Directive 2006/95/EC of the European Parliament and of the Council of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits (LV Directive). 13 Council Directive 93/68/EEC a

49、mending Directives 87/404/EEC (simple pressure vessels), 88/378/EEC (safety of toys), 89/106/EEC (construction products), 89/336/EEC (electromagnetic compatibility), 89/392/EEC (machinery), 89/686/EEC (personal protective equipment), 90/384/EEC (non-automatic weighing instruments), 90/385/EEC (active implantable medicinal devices), 90/396/EEC (appliances burning gaseous fuels), 91/263/EEC (telecommunications terminal equipment), 92/42/EEC (new hot-water boilers fired with liquid or gaseous fuels) and 73/23/EEC (electr

展开阅读全文
相关资源
猜你喜欢
  • ASTM B810-2001a(2017) Standard Test Method for Calibration of Atmospheric Corrosion Test Chambers by Change in Mass of Copper Coupons《根据铜取样片质量变化校准大气腐蚀实验室的标准试验方法》.pdf ASTM B810-2001a(2017) Standard Test Method for Calibration of Atmospheric Corrosion Test Chambers by Change in Mass of Copper Coupons《根据铜取样片质量变化校准大气腐蚀实验室的标准试验方法》.pdf
  • ASTM B811-2002(2007) Standard Specification for Wrought Zirconium Alloy Seamless Tubes for Nuclear Reactor Fuel Cladding《核反应堆燃料包壳用锻制锆合金无缝管的标准规范》.pdf ASTM B811-2002(2007) Standard Specification for Wrought Zirconium Alloy Seamless Tubes for Nuclear Reactor Fuel Cladding《核反应堆燃料包壳用锻制锆合金无缝管的标准规范》.pdf
  • ASTM B811-2013 Standard Specification for Wrought Zirconium Alloy Seamless Tubes for Nuclear Reactor Fuel Cladding《核反应堆燃料包壳用锻制锆合金无缝管的标准规格》.pdf ASTM B811-2013 Standard Specification for Wrought Zirconium Alloy Seamless Tubes for Nuclear Reactor Fuel Cladding《核反应堆燃料包壳用锻制锆合金无缝管的标准规格》.pdf
  • ASTM B811-2013(2017) Standard Specification for Wrought Zirconium Alloy Seamless Tubes for Nuclear Reactor Fuel Cladding《核反应堆燃料包壳用锻制锆合金无缝管的标准规格》.pdf ASTM B811-2013(2017) Standard Specification for Wrought Zirconium Alloy Seamless Tubes for Nuclear Reactor Fuel Cladding《核反应堆燃料包壳用锻制锆合金无缝管的标准规格》.pdf
  • ASTM B811-2013e1 Standard Specification for Wrought Zirconium Alloy Seamless Tubes for Nuclear Reactor Fuel Cladding《核反应堆燃料包壳用锻制锆合金无缝管的标准规格》.pdf ASTM B811-2013e1 Standard Specification for Wrought Zirconium Alloy Seamless Tubes for Nuclear Reactor Fuel Cladding《核反应堆燃料包壳用锻制锆合金无缝管的标准规格》.pdf
  • ASTM B812-1996(2002)e1 Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Applicati.pdf ASTM B812-1996(2002)e1 Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Applicati.pdf
  • ASTM B812-1996(2008) Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Application.pdf ASTM B812-1996(2008) Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Application.pdf
  • ASTM B812-1996(2013) Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Application.pdf ASTM B812-1996(2013) Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Application.pdf
  • ASTM B813-2000(2009) Standard Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube.pdf ASTM B813-2000(2009) Standard Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1