ETSI TS 103 159-1-2014 Digital Enhanced Cordless Telecommunications (DECT) Ultra Low Energy (ULE) Machine to Machine Communications Part 1 Test Framework and Profile Test Specifica_1.pdf

上传人:eveningprove235 文档编号:739825 上传时间:2019-01-11 格式:PDF 页数:97 大小:828.06KB
下载 相关 举报
ETSI TS 103 159-1-2014 Digital Enhanced Cordless Telecommunications (DECT) Ultra Low Energy (ULE) Machine to Machine Communications Part 1 Test Framework and Profile Test Specifica_1.pdf_第1页
第1页 / 共97页
ETSI TS 103 159-1-2014 Digital Enhanced Cordless Telecommunications (DECT) Ultra Low Energy (ULE) Machine to Machine Communications Part 1 Test Framework and Profile Test Specifica_1.pdf_第2页
第2页 / 共97页
ETSI TS 103 159-1-2014 Digital Enhanced Cordless Telecommunications (DECT) Ultra Low Energy (ULE) Machine to Machine Communications Part 1 Test Framework and Profile Test Specifica_1.pdf_第3页
第3页 / 共97页
ETSI TS 103 159-1-2014 Digital Enhanced Cordless Telecommunications (DECT) Ultra Low Energy (ULE) Machine to Machine Communications Part 1 Test Framework and Profile Test Specifica_1.pdf_第4页
第4页 / 共97页
ETSI TS 103 159-1-2014 Digital Enhanced Cordless Telecommunications (DECT) Ultra Low Energy (ULE) Machine to Machine Communications Part 1 Test Framework and Profile Test Specifica_1.pdf_第5页
第5页 / 共97页
点击查看更多>>
资源描述

1、 ETSI TS 103 159-1 V1.1.1 (2014-04) Digital Enhanced Cordless Telecommunications (DECT); Ultra Low Energy (ULE); Machine to Machine Communications; Part 1: Test Framework and Profile Test Specification (PTS) for Home Automation Network (phase 1) Technical Specification ETSI ETSI TS 103 159-1 V1.1.1

2、(2014-04)2Reference DTS/DECT-ULE269-1 Keywords DECT, IMT-2000, intelligent homes Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/ipr.etsi.org). Pursuant

3、to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document

4、. Foreword This Technical Specification (TS) has been produced by ETSI Technical Committee Digital Enhanced Cordless Telecommunications (DECT). The present document is part 1 of a multi-part deliverable covering the test specification of DECT Ultra Low Energy (ULE); as identified below: Part 1: Test

5、 Framework and Profile Test Specification (PTS) for Home Automation Network (phase 1); Part 2: Test Case Library (TCL) for Home Automation Network (phase 1); Part 3: Protocol Implementation Conformance Statement (PICS) for Home Automation Network (phase 1). The present document defines the Test Fram

6、ework and the Profile Test Specification (PTS) for Home Automation Network (phase 1). Home Automation Network (phase 1) is defined as the functionality provided by TS 102 939-1 10. Further parts of this multi-part deliverable covering the Test Case Library or additional test specifications for ULE p

7、hase 1 or further phases will be defined in the future by other parts of this multi-part deliverable. The present document is part of the testing specification of DECT Ultra Low Energy (ULE). The present document is based on TS 102 939-1 10 (DECT ULE; Home Automation Network - phase 1) and on EN 300

8、 175, parts 1 to 8 1 to 8 (DECT Common Interface). The present document has been developed in accordance to the rules of documenting a profile specification as described in ISO/IEC 9646-6 i.6. The information in the present document is believed to be correct at the time of publication. However, DECT

9、 standardization is a rapidly changing area, and it is possible that some of the information contained in the present document may become outdated or incomplete within relatively short time-scales. ETSI ETSI TS 103 159-1 V1.1.1 (2014-04)61 Scope The present document contains the Test Framework and t

10、he Profile Test Specification (PTS) for “DECT Ultra Low Energy (ULE); Machine to Machine Communications; Part 1: Home Automation Network (phase 1) (TS 102 939-1 10)“. The present document covers both the Portable (PT) and the Fixed (FT) Radio terminations. The objective of the present document is to

11、 provide a basis for approval tests of DECT Ultra Low Energy Part 1 equipment giving a high probability of air interface inter-operability between different manufacturers DECT equipment. The scope of the present document does not cover radio conformance test. The radio conformance is covered by the

12、following documents: For devices operating in the DECT frequency band (1 880 MHz to 1 900 MHz): the radio test specification EN 300 176-1 i.1 and EN 301 406 i.2. For devices operating in the IMT-2000 frequency band (1 900 MHz to 1 920 MHz and other frequency bands): EN 301 908-10 i.3. The ISO standa

13、rd for the methodology of conformance testing (ISO/IEC 9646-1 i.4 and ISO/IEC 9646-2 i.5) as well as the ETSI rules for conformance testing (ETS 300 406 i.8) are used as a basis for the test methodology. 2 References References are either specific (identified by date of publication and/or edition nu

14、mber or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. Referenced documents which are not found to be publicly available in the expected location

15、might be found at http:/docbox.etsi.org/Reference. NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long term validity. 2.1 Normative references The following referenced documents are necessary for the application of the present do

16、cument. 1 ETSI EN 300 175-1: “Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI); Part 1: Overview“. 2 ETSI EN 300 175-2: “Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI); Part 2: Physical layer (PHL)“. 3 ETSI EN 300 175-3: “Digital Enhanced Cordles

17、s Telecommunications (DECT); Common Interface (CI); Part 3: Medium Access Control (MAC) layer“. 4 ETSI EN 300 175-4: “Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI); Part 4: Data Link Control (DLC) layer“. 5 ETSI EN 300 175-5: “Digital Enhanced Cordless Telecommunications

18、 (DECT); Common Interface (CI); Part 5: Network (NWK) layer“. 6 ETSI EN 300 175-6: “Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI); Part 6: Identities and addressing“. 7 ETSI EN 300 175-7: “Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI); Part 7

19、: Security features“. ETSI ETSI TS 103 159-1 V1.1.1 (2014-04)78 ETSI EN 300 175-8: “Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI); Part 8: Speech and audio coding and transmission“. 9 ETSI EN 300 444: “Digital Enhanced Cordless Telecommunications (DECT); Generic Access P

20、rofile (GAP)“. 10 ETSI TS 102 939-1: “Digital Enhanced Cordless Telecommunications (DECT); Ultra Low Energy (ULE); Machine to Machine Communications; Part 1: Home Automation Network (phase 1)“. 11 ETSI TS 102 527-3: “Digital Enhanced Cordless Telecommunications (DECT); New Generation DECT; Part 3: E

21、xtended Wideband Speech Services“. 2.2 Informative references The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. i.1 ETSI EN 300 176-1: “Digital Enhanced Cordless Telecommunications (DECT

22、); Test specification; Part 1: Radio“. i.2 ETSI EN 301 406: “Digital Enhanced Cordless Telecommunications (DECT); Harmonized EN for Digital Enhanced Cordless Telecommunications (DECT) covering the essential requirements under article 3.2 of the R Generic radio“. i.3 ETSI EN 301 908-10: “Electromagne

23、tic compatibility and Radio spectrum Matters (ERM); Base Stations (BS), Repeaters and User Equipment (UE) for IMT-2000 Third-Generation cellular networks; Part 10: Harmonized EN for IMT-2000, FDMA/TDMA (DECT) covering essential requirements of article 3.2 of the R Protocol and profile conformance te

24、sting specifications; Standardization methodology“. 3 Definitions and abbreviations 3.1 Definitions For the purposes of the present document, the terms and definitions given in TS 102 939-1 10, EN 300 175-1 1, ISO/IEC 9646-7 i.7 and the following apply: block of data: number of octets intended for t

25、ransmission without interruptions in one or several bursts NOTE: It may contain one or several SDUs. certification program: test certification procedure organized by the industry on a voluntary basis with the aim to validate that a submitted implementation meets the required specifications in order

26、to ensure full interoperability between implementations DECT application layer: top-level C-plane layer that implements the DECT application features described in TS 102 939-1 10, clause 5.1.5 and runs over ULE C-plane ETSI ETSI TS 103 159-1 V1.1.1 (2014-04)8Implementation Conformance Statement (ICS

27、): statement made by the supplier of an implementation or system claimed to conform to a given specification, stating which capabilities have been implemented test specific application logic: application layer specific for test and implemented in the test system that provides the required functional

28、ity to run the Test Cases described in the present document ULE application logic (or layer): application layer that implements the ULE application functionality and runs over the ULE U-plane ULE Phase 1 equipment: Portable Part or Fixed Part compliant with TS 102 939-1 10. U-plane test vector: stre

29、am of octets composed of one or several SDUs that should be transmitted consecutively over the ULE U-plane during the execution of the test procedures 3.2 Symbols and abbreviations For the purposes of the present document, the symbols and abbreviations defined in TS 102 939-1 10, EN 300 175-1 1, ISO

30、/IEC 9646-1 i.4, ISO/IEC 9646-6 i.6, ISO/IEC 9646-7 i.7 and the following apply: API Application Programming Interface ICS Implementation Conformance Statement IUT Implementation Under Test PICS Protocol Implementation Conformance Statement SAP Service Access Point SDK Software Development Kit SF1 S

31、ervice access interface for FP level 1 SP1 Service access interface for PP level 1 TF0 Test interface for FP level 0 TF1 Test interface for FP level 1 TP Test Purposes TP0 Test interface for PP level 0 TP1 Test interface for PP level 1 TS Test System 4 Overview and structure 4.1 Structure of the pre

32、sent document The present document contains the following elements of the conformance test specifications of DECT Ultra Low Energy (ULE); Part 1: Home Automation Network (phase 1) (TS 102 939-1 10): Test framework and test architecture Test interface specification Test Specification conventions Prof

33、ile Test Specification, Test Cases and Test Purposes ULE Services, features and procedures to Test Cases traceability table Additionally it includes the following annexes: Description format of U-plane test vectors Parameters for static and negotiated capabilities ETSI ETSI TS 103 159-1 V1.1.1 (2014

34、-04)9The present document will be complemented with the following test specifications to be created in the future by means of separate parts of this multi-part deliverable: PT and FT Test Case Library Run time view of the Test Specification Protocol Implementation Conformance Statement (PICS) The pu

35、rpose of each one of the different sections is described in the following clauses. 4.2 Overview of the different sections 4.2.1 Overview and Structure “Overview and Structure“ is the present clause of the present document. It explains the structure and content of the different parts of the present d

36、ocument and other parts of this multi-part deliverable. 4.2.2 Test framework and test architecture Test architecture and Test method used to test the protocol conformance of DECT ULE equipment are described in clause 5. Clause 5 starts with an overview on the global ULE protocol architecture and the

37、 foreseen DECT ULE standards ecosystem. Then, the specific test configurations for PT and FT conformance testing are introduced. As part of this architecture, the test interfaces TF1 and TP1 are created and their position in the overall schema is defined. 4.2.3 Test interface specification Clause 6

38、defines the test interfaces TF1 and TP1 created by the test architecture and used in the rest of the present document. In order to make possible some flexibility in the initial implementation of the interface, only a top level definition, named “functional definition“ is provided. This allows flexib

39、ility for multiple implementations of the interface that may include Man-Machine-Interfaces (MMI) or not. 4.2.4 Profile Test Specification, Introduction and conventions Clause 7.1 is an introductory section to the Profile Test Specification (PTS). It provides an overview and defines the conventions

40、that will be used in the rest of the clause. 4.2.5 Profile Test Specification, Test Cases and Test Purposes (definition view) The “Profile Test Specification, Test Cases and Test Purposes (definition view)“ is the core part of the present document from test process specification point of view and is

41、 described in clause 7.2. Clause 7.2 creates and defines the different Test Groups, Test Purposes and Test Cases that will be part of the test specification suite. The clause also defines the status (mandatory, optional or conditional) of each Test Case. 4.2.6 ULE Services, features and procedures t

42、o Test Cases traceability table Clause 7.3 provides a set of tables that define the traceability between the Test Cases defined in the present document and the services, features and procedures defined in TS 102 939-1 10. In other words, the tables included in clause 7.3 provide information about wh

43、ich Test Cases are testing the different services, features and procedures defined in the main specification. ETSI ETSI TS 103 159-1 V1.1.1 (2014-04)104.2.7 Description format of U-plane test vectors The description format of the U-plane vectors is described in annex A. The bit content of the vector

44、s themselves will be given in the Test Case Library. The annex may be seen as an extension of clause 6 defining the interfaces TP1 and TF1. 4.2.8 Parameters for static and negotiated capabilities Annex B introduces the list of parameters describing capabilities that are either inherent of the IUT or

45、 that are negotiated using an application protocol and that need to be exchanged through the interfaces TP1 or TF1 during the test preparation process. The test commands “Retrieve Static capabilities“ and “Store Negotiated capabilities“ (see clause 6.3.1, table 1) allows to emulate the negotiation p

46、rocess during the Test setup stage. The test specification will be complemented with the following parts to be created in the future by means of separate parts of this multi-part deliverable: 4.2.9 PT and FT Test Case Library The Test Case Library defines the detailed content of the Test Cases, incl

47、uding sequence diagrams, states, stimulus and pass criteria. The Test Cases and Test Purpose are defined in clause 7.2 of the present document. The Test Case Library will be implemented as a separate part (part 2) of this multi-part deliverable. 4.2.10 Run time view of the Test Specification The Run

48、 time view of the Test Specification defines the execution view of the test certification program. In order to do that, the Test Cases are grouped in execution sequences that will be a functional execution unit in the test systems. Sequences are chosen according to technical convenience for the desi

49、gn and implementation of the test equipment and may include multiple Test Cases testing multiple layers. The Run time view of the Test Specification will be included in part 2 of this multi-part deliverable 4.2.11 Protocol Implementation Conformance Statement (PICS) The Protocol Implementation Conformance Statement (PICS) proforma is the document that shall be filled by the supplier of any implementation subject to test under the scope of the present document stating which capabilities have b