1、 ETSI TS 103 268-2 V1.1.1 (2017-04) SmartM2M; Smart Appliances Ontology and Communication Framework Testing; Part 2: Protocol Implementation Conformance Statement (PICS) pro forma TECHNICAL SPECIFICATION ETSI ETSI TS 103 268-2 V1.1.1 (2017-04)2 Reference DTS/SmartM2M-103 268-2_SAP PIC Keywords IoT,
2、M2M, PICS, Smart Appliance, testing ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice The present
3、 document can be downloaded from: http:/www.etsi.org/standards-search The present document may be made available in electronic versions and/or in print. The content of any electronic and/or print versions of the present document shall not be modified without the prior written authorization of ETSI.
4、In case of any existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the
5、document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at https:/portal.etsi.org/TB/ETSIDeliverableStatus.aspx If you find errors in the present document, please send your comment to one of the following services: http
6、s:/portal.etsi.org/People/CommiteeSupportStaff.aspx Copyright Notification No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm except as authorized by written permission of ETSI. The content of the PDF version shall not be
7、 modified without the written authorization of ETSI. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2017. All rights reserved. DECTTM, PLUGTESTSTM, UMTSTMand the ETSI logo are Trade Marks of ETSI registered for the ben
8、efit of its Members. 3GPPTM and LTE are Trade Marks of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM and the GSM logo are Trade Marks registered and owned by the GSM Association. ETSI ETSI TS 103 268-2 V1.1.1 (2017-04)3 Contents Intellectual Property Rig
9、hts 4g3Foreword . 4g3Modal verbs terminology 4g31 Scope 5g32 References 5g32.1 Normative references . 5g32.2 Informative references 5g33 Definitions and abbreviations . 6g33.1 Definitions 6g33.2 Abbreviations . 6g34 Conformance requirement concerning PICS 6g3Annex A (normative): Smart Appliances Tes
10、ting PICS Pro forma . 7g3A.0 Foreword 7g3A.1 Guidance for completing the ICS pro forma 7g3A.1.1 Purposes and structure 7g3A.1.2 Abbreviations and conventions 7g3A.1.3 Instructions for completing the ICS pro forma . 9g3A.2 Identification of the implementation 9g3A.2.1 Introduction 9g3A.2.2 Date of th
11、e statement 9g3A.2.3 Implementation Under Test (IUT) identification . 9g3A.2.4 System Under Test (SUT) identification 10g3A.2.5 Product supplier 10g3A.2.6 Client (if different from product supplier) 10g3A.2.7 ICS contact person 11g3A.3 Identification of the reference specifications . 11g3A.4 Global
12、statement of conformance . 12g3A.5 Tables . 12g3A.5.1 oneM2M Resource Type Statement . 12g3A.5.2 SAREF Device Class Statement . 12g3A.5.3 SAREF Function Class Statement 12g3A.5.4 SAREF Service Class Statement 13g3A.5.5 SAREF Property Class Statement 13g3A.5.6 SAREF Command Class Statement . 14g3A.5.
13、7 SAREF Device Category Class Statement . 14g3A.5.8 SAREF State Class Statement 15g3A.5.9 SAREF Task Class Statement 15g3A.5.10 SAREF Unit of Measure Class Statement 15g3A.5.11 SAREF Commodity Class Statement . 16g3A.5.12 SAREF Building Object Class Statement 16g3A.5.13 SAREF Building Space Class St
14、atement 16g3A.5.14 SAREF Profile Class Class Statement 16g3A.5.15 SAREF Function Category Class Statement 17g3A.5.16 SAREF Object Properties Statement 17g3A.5.17 SAREF Data Type Statement . 17g3A.5.18 oneM2M Operation Statement . 18g3A.5.19 oneM2M Thing Statement 18g3A.5.20 oneM2M Aspect Statement 1
15、8g3History 19 ETSI ETSI TS 103 268-2 V1.1.1 (2017-04)4 Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and
16、can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (https:/ipr.etsi.org/). Pursuant to the E
17、TSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Forewo
18、rd This Technical Specification (TS) has been produced by ETSI Technical Committee Smart Machine-to-Machine communications (SmartM2M). The present document is part 2 of a multi-part deliverable covering Conformance test specifications for Smart Appliances Ontology and Communication Framework Testing
19、 as identified below: Part 1: “Testing methodology“; Part 2: “Protocol Implementation Conformance Statement (PICS) pro forma“; Part 3: “Test Suite Structure and Test Purposes (TSS Part 4: “Abstract Test Suite (ATS) and Protocol Implementation eXtra Information for Testing (PIXIT)“. Modal verbs termi
20、nology In the present document “shall“, “shall not“, “should“, “should not“, “may“, “need not“, “will“, “will not“, “can“ and “cannot“ are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of provisions). “must“ and “must not“ are NOT allowed in
21、 ETSI deliverables except when used in direct citation. ETSI ETSI TS 103 268-2 V1.1.1 (2017-04)5 1 Scope The present document provides the Protocol Implementation Conformance Statement (PICS) pro forma for Conformance test specifications for Smart Appliances testing as defined in ETSI TS 103 268-1 6
22、 and ETSI TS 118 115 8 in compliance with the relevant requirements and in accordance with the relevant guidance given in ISO/IEC 9646-7 7. 2 References 2.1 Normative references References are either specific (identified by date of publication and/or edition number or version number) or non-specific
23、. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. Referenced documents which are not found to be publicly available in the expected location might be found at https:/docbox.etsi.or
24、g/Reference. NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long term validity. The following referenced documents are necessary for the application of the present document. 1 ETSI TS 103 264: “SmartM2M; Smart Appliances; Referen
25、ce Ontology and oneM2M Mapping“. 2 ETSI TS 103 267: “SmartM2M; Smart Appliances; Communication Framework“. 3 ETSI TS 118 101: “oneM2M; Functional Architecture (oneM2M TS-0001)“. 4 ETSI TS 118 104: “oneM2M; Service Layer Core Protocol Specification (oneM2M TS-0004)“. 5 ETSI TS 118 112: “oneM2M; Base
26、Ontology (oneM2M TS-0012)“. 6 ETSI TS 103 268-1: “SmartM2M; Smart Appliances Ontology and Communication Framework Testing; Part 1: Testing methodology“. 7 ISO/IEC 9646-7: “Information technology - Open Systems Interconnection - Conformance testing methodology and framework - Part 7: Implementation C
27、onformance Statements“. 8 ETSI TS 118 115: “oneM2M; Testing Framework (oneM2M TS-0015)“. 9 ISO/IEC 9646-1: “Information technology - Open Systems Interconnection - Conformance testing methodology and framework - Part 1: General concepts“. 2.2 Informative references References are either specific (id
28、entified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. NOTE: While any hyperlinks included in thi
29、s clause were valid at the time of publication, ETSI cannot guarantee their long term validity. The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. Not applicable. ETSI ETSI TS 103 268-2 V
30、1.1.1 (2017-04)6 3 Definitions and abbreviations 3.1 Definitions For the purposes of the present document, the terms and definitions given in ETSI TS 103 268-1 6, ISO/IEC 9646-1 9 and ISO/IEC 9646-7 7 apply. 3.2 Abbreviations For the purposes of the present document, the abbreviations given in ETSI
31、TS 103 268-1 6, ETSI TS 103 264 1, ETSI TS 118 112 5 and the following apply: API Application Programming Interface EUT Equipment Under Test IFS Interoperable Features Statement IUT Implementation Under Test IWF InterWorking Function PICS Protocol Implementation Conformance Statement QE Qualified Eq
32、uipment RP Reference Point SAP Smart Appliance SUT System Under Test TP Test Purpose TSS Test Suite Structure 4 Conformance requirement concerning PICS If it claims to conform to the present document, the actual PICS pro forma to be filled in by a supplier shall be technically equivalent to the text
33、 of the PICS pro forma given in annex A, and shall preserve the numbering, naming and ordering of the pro forma items. An ICS which conforms to the present document shall be a conforming PICS pro forma completed in accordance with the instructions for completion given in clause A.1. ETSI ETSI TS 103
34、 268-2 V1.1.1 (2017-04)7 Annex A (normative): Smart Appliances Testing PICS Pro forma A.0 Foreword Notwithstanding the provisions of the copyright clause related to the text of the present document, ETSI grants that users of the present document may freely reproduce the Smart Appliances PICS pro for
35、ma in this annex so that it can be used for its intended purposes and may further publish the completed Smart Appliances PICS. A.1 Guidance for completing the ICS pro forma A.1.1 Purposes and structure The purpose of this ICS pro forma is to provide a mechanism whereby a supplier of an implementatio
36、n of the requirements defined in ETSI TS 118 101 3 may provide information about the implementation in a standardized manner. The ICS pro forma is subdivided into clauses for the following categories of information: guidance for completing the ICS pro forma; identification of the implementation; ide
37、ntification of the ETSI TS 118 101 3; global statement of conformance; ICS pro forma tables. A.1.2 Abbreviations and conventions The ICS pro forma contained in this annex is comprised of information in tabular form in accordance with the guidelines presented in ISO/IEC 9646-7 7. Item column The item
38、 column contains a number which identifies the item in the table. Item description column The item description column describes in free text each respective item (e.g. parameters, timers, etc.). It implicitly means “is supported by the implementation?“. Reference column The reference column gives re
39、ference to the relevant clauses in core specifications. Status column The various status used in this annex are in accordance with the rules in table A.1.2-1. ETSI ETSI TS 103 268-2 V1.1.1 (2017-04)8 Table A.1.2-1: Key to status codes Status code Status name Meaning m mandatory The capability shall
40、be supported. It is a static view of the fact that the conformance requirements related to the capability in the reference specification are mandatory requirements. This does not mean that a given behaviour shall always be observed (this would be a dynamic view), but that it shall be observed when t
41、he implementation is placed in conditions where the conformance requirements from the reference specification compel it to do so. For instance, if the support for a parameter in a sent PDU is mandatory, it does not mean that it shall always be present, but that it shall be present according to the d
42、escription of the behaviour in the reference specification (dynamic conformance requirement). o optional The capability may or may not be supported. It is an implementation choice. n/a not applicable It is impossible to use the capability. No answer in the support column is required. c. conditional
43、The requirement on the capability (“m“, “o“, “n/a“) depends on the support of other optional or conditional items. is the identifier of the conditional expression. o. qualified optional For mutually exclusive or selectable options from a set. is the identifier of the group of options, and the logic
44、of selection of the options. Mnemonic column The Mnemonic column contains mnemonic identifiers for each item. Support column The support column shall be filled in by the supplier of the implementation. The following common notations, defined in ISO/IEC 9646-7 7, are used for the support column: Y or
45、 y supported by the implementation N or n not supported by the implementation N/A, n/a or - no answer required (allowed only if the status is N/A, directly or after evaluation of a conditional status) References to items For each possible item answer (answer in the support column) within the ICS pro
46、 forma there exists a unique reference, used, for example, in the conditional expressions. It is defined as the table identifier, followed by a solidus character “/“, followed by the item number in the table. EXAMPLE 1: A.5/4 is the reference to the answer of item 4 in table A.5. EXAMPLE 2: A.6/3b i
47、s the reference to the second answer (i.e. in the second support column) of item 3 in table 6 of annex A. Values allowed column The values allowed column contains the type, the list, the range, or the length of values allowed. The following notations are used: - range of values: example: 5 20 - list
48、 of values: , , ., example: 2 ,4 ,6 ,8, 9 example: 1101B, 1011B, 1111B example: 0AH, 34H, 2FH - list of named values: (), (), ., () example: reject(1), accept(2) - length: size ( ) ETSI ETSI TS 103 268-2 V1.1.1 (2017-04)9 example: size (1 8) Values supported column The values supported column shall
49、be filled in by the supplier of the implementation. In this column, the values or the ranges of values supported by the implementation shall be indicated. Prerequisite line A prerequisite line takes the form: Prerequisite: . A prerequisite line after a clause or table title indicates that the whole clause or the whole table is not required to be completed if the predicate is FALSE. A.1.3 Instructions for completing the ICS pro forma The supplier of the implementation shall complete the ICS pro forma in each o