1、 Manufacturing StandardsFord Motor Company199206 FLAT BELT CONVEYORS CX9Engineering Standards & Printed copies are uncontrolled.Systems Engineering (ESSE) Page 1 of 21. SCOPE: This standard covers flat belt conveyors used for movingcontainers and parts.2. REFERENCES:Ford Manufacturing StandardsEM1 -
2、 AC Electric Motors Totally - Enclosed TypeEX1 - Electrical Standard for Mass Production EquipmentKH1 - Machine Components, Hubs - InterchangeabiltyKV1 - V-Belts and DrivesLX1 - Lubrication Standards of Industrial EquipmentAmerican National Standards Institute (ANSI)ASME B20.1 - Safety Standard for
3、Conveyors and Related EquipmentAmerican Institute of Steel Construction (AISC)American Welding Society (AWS)Conveyor Equipment Manufacturers Association (CEMA)CEMA 402 - Belt ConveyorsOccupational Safety and Health Administration Standards (OSHA) - Title29, Code of Federal Regulations3. GENERAL: Con
4、veyor system design must comply with the latest editionof the referenced standards. In those instances where Ford standardsexceed the referenced standards, Ford standards will apply. It is theresponsibility of the supplier to determine that all standards are met orrequest a waiver of requirements if
5、 necessary. Any waiver must beapproved by the requisitioning activity.4. CONSTRUCTION:4.1 COMPONENT PARTS: All component parts subject to wear and/orreplacement shall be bolted to facilitate maintenance and erection.4.2 GUARDS: Removable metal guards shall be provided for all movingparts and for cha
6、in returns. Guards shall be fabricated from aminimum of 16 gauge (1.5 mm) material or from expanded metalwith 3/4 inch (19 mm) maximum openings.4.3 DRIP PANS: Steel drip pans fabricated from 16 gauge (1.5 mm)material (minimum) shall be provided as required.4.4 PAINT: All surfaces except for machined
7、 and those in contact withthe belt shall be primed prior to delivery. The finish coat to bespecified by the requisitioning activity.Manufacturing StandardsFord Motor Company199206 FLAT BELT CONVEYORS CX9Engineering Standards & Printed copies are uncontrolled.Systems Engineering (ESSE) Page 2 of 24.5
8、 END-OF-TRAVEL DETECTION DEVICES: Slat conveyors with manual un-loading require “end-of-travel detection devices“ to preventaccidental discharge of loads.5. ELECTRICAL: Electric power shall be 480 Volt, 60-hertz, 3-phase.Conveyor drives shall be equipped with “instantaneous trip“ overloadrelays, app
9、roved by the requisitioning activity.Relays shall be wired so that the conveyor can be restarted only from apush button located at the control center of control panel.6. PULLEYS AND ROLLERS: Provisions shall be provided for tracking andadjustment.7. SIDE RAILS: Side rails shall be provided unless otherwise specified bythe requisitioning activity.8. EMERGENCY STOPS: Emergency stop buttons or pull stop cables shall beprovided along all working areas as specified by requisitioning activity.