FORD ESB-M99J314-A-2012 CATALYST ACID - POLYESTER BASECOAT CLEARCOAT LOW BAKE REPAIR PROCESS (MALEIC ACID) TO BE USED WITH FORD WSS-M99P1111-A 《酸催化剂 低烘烤修复工艺(马来酸)聚酯底涂层 清漆 与福特WSS-.pdf

上传人:medalangle361 文档编号:745781 上传时间:2019-01-14 格式:PDF 页数:2 大小:40.49KB
下载 相关 举报
FORD ESB-M99J314-A-2012 CATALYST ACID - POLYESTER BASECOAT CLEARCOAT LOW BAKE REPAIR PROCESS (MALEIC ACID)  TO BE USED WITH FORD WSS-M99P1111-A  《酸催化剂 低烘烤修复工艺(马来酸)聚酯底涂层 清漆  与福特WSS-.pdf_第1页
第1页 / 共2页
FORD ESB-M99J314-A-2012 CATALYST ACID - POLYESTER BASECOAT CLEARCOAT LOW BAKE REPAIR PROCESS (MALEIC ACID)  TO BE USED WITH FORD WSS-M99P1111-A  《酸催化剂 低烘烤修复工艺(马来酸)聚酯底涂层 清漆  与福特WSS-.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 ENGINEERING MATERIAL SPECIFICATION Date Action Revisions Rev 02 2012 02 16 N Status No replacements named N. Benipal, NA 2005 08 29 Revised Inserted 3.0; deleted 3.8 and 4 1985 03 12 Released C51-RD528863 Controlled document at www.MATS Copyright 2012, Ford Global Technologies, LLC Page 1 of 2 CATA

2、LYST, ACID - POLYESTER BASECOAT/CLEARCOAT LOW ESB-M99J314-A BAKE REPAIR PROCESS (MALEIC ACID) NOT TO BE USED FOR NEW DESIGN 1. SCOPE The material defined by this specification is an acid catalyst solution used to convert standard bake polyester basecoat/clearcoat enamels to low bake paint repair coa

3、tings. 2. APPLICATION Catalyzed low bake in-plant repair of painted passenger car exterior surfaces. 3. REQUIREMENTS 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A).

4、3.1 SPECIFIC GRAVITY, 25/25 C 0.990 - 1.020 (ASTM D 891) 3.2 ACID NUMBER 160 (ASTM D 1647) 3.3 FLASH POINT, C, min 43 (ASTM D 56) 3.4 COMPOSITION (PERCENT BY WEIGHT) Maleic Acid 20 Cellosolve 80 3.5 INCORPORATION OF CATALYST Basecoat portion is not catalyzed. Catalyst is incorporated into clearcoat

5、at 5% by volume under following conditions: Clearcoat Viscosity 25 +/- 0.1 C 24 - 28 s (ASTM D 1200) Clearcoat Non-volatile 35 - 39% (FLTM BI 102-01) 3.6 BAKE SCHEDULE Ambient 20 min at 99 C Metal Temp. 10 min at 99 C ENGINEERING MATERIAL SPECIFICATION ESB-M99J314-A Copyright 2012, Ford Global Techn

6、ologies, LLC Page 2 of 2 3.7 PERFORMANCE Catalyzed repair enamel applied per requirements of the standard bake system. Final appearance, gloss, intercoat adhesion, weathering and resistance properties shall be consistent with the standard requirements. Catalyzed repair film shall have a Tukon value of 4 - 5 K.H.N. 5. GENERAL INFORMATION The information given below is provided for clarification and assistance in meeting the requirements of this specification. This material has a useable shelf life of three(3) months due to the degenerative nature of the acid catalyst.

展开阅读全文
相关资源
猜你喜欢
  • ANSI ISA 60079-27-2006 Fieldbus Intrinsically Safe Concept (FISCO) and Fieldbus Non-Incendive Concept (FNICO) (12.02.04).pdf ANSI ISA 60079-27-2006 Fieldbus Intrinsically Safe Concept (FISCO) and Fieldbus Non-Incendive Concept (FNICO) (12.02.04).pdf
  • ANSI ISA 60079-28-2012 Explosive Atmospheres C Part 28 Protection of equipment and transmission systems using optical radiation (Edition 1.1 12.21.02)《爆炸性气体环境.第28部分 用光辐射的传输系统和设备的保护.pdf ANSI ISA 60079-28-2012 Explosive Atmospheres C Part 28 Protection of equipment and transmission systems using optical radiation (Edition 1.1 12.21.02)《爆炸性气体环境.第28部分 用光辐射的传输系统和设备的保护.pdf
  • ANSI ISA 60079-29-1-2013 Explosive Atmospheres C Part 29-1 Gas detectors C Performance requirements of detectors for flammable gases (12.13.01 Second Printing March 12 2014).pdf ANSI ISA 60079-29-1-2013 Explosive Atmospheres C Part 29-1 Gas detectors C Performance requirements of detectors for flammable gases (12.13.01 Second Printing March 12 2014).pdf
  • ANSI ISA 60079-29-2-2012 Explosive Atmospheres C Part 29-2 Gas detectors C Selection installation use and maintenance of detectors for flammable gases and oxygen (12.13.02)《爆燃性环境.第.pdf ANSI ISA 60079-29-2-2012 Explosive Atmospheres C Part 29-2 Gas detectors C Selection installation use and maintenance of detectors for flammable gases and oxygen (12.13.02)《爆燃性环境.第.pdf
  • ANSI ISA 60079-31-2015 Explosive Atmospheres C Part 31 Equipment Dust Ignition Protection by Enclosure t (Edition 2 12.10.03).pdf ANSI ISA 60079-31-2015 Explosive Atmospheres C Part 31 Equipment Dust Ignition Protection by Enclosure t (Edition 2 12.10.03).pdf
  • ANSI ISA 60079-6-2013 Explosive Atmospheres - Part 6 Equipment Protection by Oil Immersion  o  (Third Edition 12.00.05)《爆炸性气体.第6部分 油浸 o 型防护设备》.pdf ANSI ISA 60079-6-2013 Explosive Atmospheres - Part 6 Equipment Protection by Oil Immersion o (Third Edition 12.00.05)《爆炸性气体.第6部分 油浸 o 型防护设备》.pdf
  • ANSI ISA 60079-7-2008 Explosive Atmospheres - Part 7 Equipment protection by increased safety  e  (Fourth Edition 12.16.01)《I类1区危险(已分类)场所用电气设备.保护类型.安全性增强 e 型》.pdf ANSI ISA 60079-7-2008 Explosive Atmospheres - Part 7 Equipment protection by increased safety e (Fourth Edition 12.16.01)《I类1区危险(已分类)场所用电气设备.保护类型.安全性增强 e 型》.pdf
  • ANSI ISA 61010-031-2007 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use C Part 031 Safety requirements for hand-held probe assemblies for el.pdf ANSI ISA 61010-031-2007 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use C Part 031 Safety requirements for hand-held probe assemblies for el.pdf
  • ANSI ISA 61010-2-030-2012 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT CONTROL AND LABORATORY USE C Part 2-030 Particular requirements for testing and measuring cir.pdf ANSI ISA 61010-2-030-2012 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT CONTROL AND LABORATORY USE C Part 2-030 Particular requirements for testing and measuring cir.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1