资源描述

1、 ENGINEERING MATERIAL SPECIFICATION Date Action Revisions Rev. 4 2013 10 25 N-Status N-Status for B1 and B2. No Replacement Named A. Wedepohl 2008 08 28 Revised Revised 2, Deleted 3.9, 3.10 Inserted 3.0 C. McComb, FNA 1978 10 04 ESE-M13P6-B1 use 1/2 in (13 mm) scratch and use tape from Method “B“) M

2、ust not flake, chip, or transfer film to tape. 3.5 CURE TEST AND SOLVENT RESISTANCE No softening of the coating or evidence of color rubbing off when a cloth dipped in MEK is rubbed twice over the surface of the coating. ENGINEERING MATERIAL SPECIFICATION ESE-M13P6-B1/B2 Copyright 2013, Ford Global

3、Technologies, LLC Page 2 of 3 3.6 PANEL TESTING Tests shall be conducted on coated panels of low carbon steel (ESE-M1A140-A) conforming to para 3.1 through 3.5. 3.6.1 Salt Spray 500 h (ASTM B 117) Panels must meet a rating of no lower than #7 per ASTM D 1654, Schedule No. 2. 3.6.2 Coefficient of Fri

4、ction, max 0.12 (FLTM BQ 13-1) Static i.e. using coated test specimen and omitting oils, test run at room temperature until coating wear is indicated by kinetic coefficient of friction reaching 0.30. 3.8 FINISHED PART Parts must meet para 3.1 through 3.5, other requirements when required shall be sp

5、ecified on the engineering drawings or engineering specification for parts with this coating (as configuration permits). 3.8.1 Salt Spray 300 h (ASTM B 117) (Approval - ISIR) 96 h (Lot certification per Q-101) Parts must meet a rating of no lower than #7 per ASTM D 1654, Schedule No.2. The above req

6、uirements for both thickness and salt spray apply only to significant surfaces. The specified coating thickness shall be required only on such surfaces of parts other than threads or holes, as can be touched by a sphere 0.5 in (13 mm) in diameter, unless otherwise noted on drawings. On other surface

7、s such as those of holes, recesses, threads, etc., where a controlled deposit cannot be obtained under normal coating conditions, the above requirements do not apply. Acceptance or rejection of parts submitted to this specification will be based on thickness and salt spray results on significant sur

8、faces. ENGINEERING MATERIAL SPECIFICATION ESE-M13P6-B1/B2 Copyright 2013, Ford Global Technologies, LLC Page 3 of 3 5. GENERAL INFORMATION The material data included herein is for information only and is not a requirement for the supplier. 5.1 OPERATING TEMPERATURE, C ESE-M13P6-B1 ESE-M13P6-B2 Conti

9、nuous 149 204 Intermittent 177 260 5.2 SELECTION OF COATING ESE-M13P6-B1: This coating is recommended for applications requiring low friction and good resistance to sliding wear. Also, where corrosion resistance is of primary concern along with possible identification of parts by color coding. Coating available either by spraying or dipping. ESE-M13P6-B2: This coating is recommended for applications requiring low friction and optimum resistance to sliding and abrasive wear. This coating is available in black only and applied only by spray.

展开阅读全文
相关资源
猜你喜欢
  • STAS 11237 1-1980 MEDICAT ELECTRICAL EQUIPMENT FOR USE IN THE PATIENT ENVIRONMENT Safety General prescription and rules《医学 用于在病人环境安全的医用电气设备 通用处方和规则》.pdf STAS 11237 1-1980 MEDICAT ELECTRICAL EQUIPMENT FOR USE IN THE PATIENT ENVIRONMENT Safety General prescription and rules《医学 用于在病人环境安全的医用电气设备 通用处方和规则》.pdf
  • STAS 11237 2-1980 MEDICAL ELECTRICAL EQUIPMENT FOR USE IN THE PATIENT ENVIRONMENT Safety Protection against electric shock《用于在病人环境的医用电气设备 安全 防触电保护》.pdf STAS 11237 2-1980 MEDICAL ELECTRICAL EQUIPMENT FOR USE IN THE PATIENT ENVIRONMENT Safety Protection against electric shock《用于在病人环境的医用电气设备 安全 防触电保护》.pdf
  • STAS 11237 22-1988 MEDICAL ELECTRICAL IGH FREQUENCY SURGICAL QUIPMENT eneral technical requirements for safety《医学的电子好频率外壳设备通用安全的技术要求 》.pdf STAS 11237 22-1988 MEDICAL ELECTRICAL IGH FREQUENCY SURGICAL QUIPMENT eneral technical requirements for safety《医学的电子好频率外壳设备通用安全的技术要求 》.pdf
  • STAS 11237 3-1980 MEDICAL ELECTRICAL EQUIPMENT FOR USE IN THE PATIENT ENVIRONMENT Safety Protection against mechanical hazards fault conditions and endurance《用于在病人环境的医用电气设备 安全 防止机械.pdf STAS 11237 3-1980 MEDICAL ELECTRICAL EQUIPMENT FOR USE IN THE PATIENT ENVIRONMENT Safety Protection against mechanical hazards fault conditions and endurance《用于在病人环境的医用电气设备 安全 防止机械.pdf
  • STAS 11237 4-1980 MEDICAL ELECTRICAL EQUIPMENT FOR USE IN THE PATIENT ENVIRONMENT Safety Construction《用于在病人环境安全的医用电气设备 建造》.pdf STAS 11237 4-1980 MEDICAL ELECTRICAL EQUIPMENT FOR USE IN THE PATIENT ENVIRONMENT Safety Construction《用于在病人环境安全的医用电气设备 建造》.pdf
  • STAS 11237 5-1980 MEDICAL ELECTRICAL EQUIPMENT FOR USE IN THE PATIENT= ENVIRONMENT Safety Protection against explosions《医学电气设备用于病人 防爆环境安全 》.pdf STAS 11237 5-1980 MEDICAL ELECTRICAL EQUIPMENT FOR USE IN THE PATIENT= ENVIRONMENT Safety Protection against explosions《医学电气设备用于病人 防爆环境安全 》.pdf
  • STAS 11238-1983 BAST FIBRES AND BAST TYPE FIBRES WOVEN FABRICS Widths《韧皮纤维和韧皮型纤维机织物 宽度》.pdf STAS 11238-1983 BAST FIBRES AND BAST TYPE FIBRES WOVEN FABRICS Widths《韧皮纤维和韧皮型纤维机织物 宽度》.pdf
  • STAS 11239-1989 Metallic coatings AYER THICKNESS DETERMINATION BY MAGNETIC METHOD《金属涂层的层厚度通过磁法测定 》.pdf STAS 11239-1989 Metallic coatings AYER THICKNESS DETERMINATION BY MAGNETIC METHOD《金属涂层的层厚度通过磁法测定 》.pdf
  • STAS 11240-1988 MODYIFING ALLOYS FOR CAST IRONS《铸铁用变质合金 》.pdf STAS 11240-1988 MODYIFING ALLOYS FOR CAST IRONS《铸铁用变质合金 》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1