FORD ESF-M99G158-A-2006 ENCAPSULANT SILICONE DIELECTRIC GEL TO BE USED WITH FORD WSS-M99P1111-A 《硅介电凝胶式密封剂 与标准FORD WSS-M99P1111-A一起使用 》.pdf

上传人:cleanass300 文档编号:746330 上传时间:2019-01-14 格式:PDF 页数:1 大小:46.30KB
下载 相关 举报
FORD ESF-M99G158-A-2006 ENCAPSULANT SILICONE DIELECTRIC GEL  TO BE USED WITH FORD WSS-M99P1111-A 《硅介电凝胶式密封剂  与标准FORD WSS-M99P1111-A一起使用 》.pdf_第1页
第1页 / 共1页
亲,该文档总共1页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 ENGINEERING MATERIAL SPECIFICATION Date Action Revisions 2006 09 19 Revised Inserted 3.0; Deleted 3.3 & 4 1980 06 18 Revised & Retyped CF4K-RD576983-7 1978 10 31 Released (Was XF-M99GX27), F4H-70 Printed copies are uncontrolled Copyright 2006, Ford Global Technologies, LLC Page 1 of 1 ENCAPSULANT,

2、SILICONE DIELECTRIC GEL ESF-M99G128-A 1. SCOPE The material defined by this specification is a very soft, 2 part, silicone gel. 2. APPLICATION This specification was released originally for a compound used in sealing and potting diodes in the alternator rectifier circuit. 3. REQUIREMENTS Material sp

3、ecification requirements are to be used for initial qualification of materials. 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.1 To be run on each lot of material

4、 3.1.1 Viscosity - Brookfield Viscometer, mm2/s (ASTM D 1084 Method “B“, model LVT, 30 rpm, #3 spindle) 3.1.1.1 Part A 200 - 700 3.1.1.2 Part B 200 - 700 3.1.1.3 Mixed 200 - 700 3.1.2 Gel Time at 135 C 5 - 15 minutes (ASTM D 2471, mix components at R.T.) 3.1.3 Hardness 3 - 8 (FLTM BJ 023-03, cured 1 h at 150 C) 3.2 To be run for Initial Approval and as required by quality control. Samples cured 1 h at 150 C. 3.2.1 Dielectric Strength, min 375 vpm (15 kV/mm) (ASTM D 149/IEC 243, 0.060 in (1.5mm) thick) 3.2.2 Specific Gravity 0.94 - 0.97 3.2.3 Volatility, loss, m x 3.0% (2 g for 2 h at 150 C)

展开阅读全文
相关资源
猜你喜欢
  • DIN 42568-1982 Transformers outlet valve DN 15 and DN 32 for sampling and discharge《变压器 取样和排放用15和32公称内径的放出阀》.pdf DIN 42568-1982 Transformers outlet valve DN 15 and DN 32 for sampling and discharge《变压器 取样和排放用15和32公称内径的放出阀》.pdf
  • DIN 42600-1-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV - Part 1 Basic requirements《50Hz Um为0 72 kV至52 kV的仪表用变压器 第1部分 基本要求》.pdf DIN 42600-1-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV - Part 1 Basic requirements《50Hz Um为0 72 kV至52 kV的仪表用变压器 第1部分 基本要求》.pdf
  • DIN 42600-2-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV - Part 2 Current transformers U = 0 72 kV and U = 1 2 kV - Main dimensions《50Hz Um为0 72 kV至52 kV的仪表用变压器 第2部分 0.pdf DIN 42600-2-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV - Part 2 Current transformers U = 0 72 kV and U = 1 2 kV - Main dimensions《50Hz Um为0 72 kV至52 kV的仪表用变压器 第2部分 0.pdf
  • DIN 42600-3-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV - Part 3 Voltage transformers U 12 kV to 36 kV - Large design main dimensions indoor type《50 Hz U 0 72 kV至52 k.pdf DIN 42600-3-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV - Part 3 Voltage transformers U 12 kV to 36 kV - Large design main dimensions indoor type《50 Hz U 0 72 kV至52 k.pdf
  • DIN 42600-4-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV - Part 4 Current Transformers (support-type-insulator) U = 12 kV - Small design main dimensions indoor type《50.pdf DIN 42600-4-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV - Part 4 Current Transformers (support-type-insulator) U = 12 kV - Small design main dimensions indoor type《50.pdf
  • DIN 42600-5-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV - Part 5 Current Transformers (support-type-insulator) U 12 kV to 36 kV - Large design main dimensions indoor .pdf DIN 42600-5-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV - Part 5 Current Transformers (support-type-insulator) U 12 kV to 36 kV - Large design main dimensions indoor .pdf
  • DIN 42600-7-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV - Part 7 Voltage Transformers U to 12 kV - Small design main dimensions indoor type《50Hz Um为0 72 kV至52 kV的仪表用变.pdf DIN 42600-7-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV - Part 7 Voltage Transformers U to 12 kV - Small design main dimensions indoor type《50Hz Um为0 72 kV至52 kV的仪表用变.pdf
  • DIN 42600-8-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV -Part 8 Current Transformers (support-type-insulators) U = 12 kV and U = 24 kV - Narrow design main dimensions.pdf DIN 42600-8-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV -Part 8 Current Transformers (support-type-insulators) U = 12 kV and U = 24 kV - Narrow design main dimensions.pdf
  • DIN 42600-9-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV - Part 9 Voltage Transformers U = 12 kV and U = 24 kV - Narrow design main dimensions indoor type《50 Hz U 0 72.pdf DIN 42600-9-2013 Instrument transformers for 50 Hz U 0 72 kV to 52 kV - Part 9 Voltage Transformers U = 12 kV and U = 24 kV - Narrow design main dimensions indoor type《50 Hz U 0 72.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1