FORD FLTM AQ 105-01-2001 DETERMINATION OF CHROMIUM OXIDE COATING WEIGHTS (Replaces FLTM EU-AQ 005-01)《氧化铬涂层重量的测定 替代FLTM EU-AQ 005-01[替代 FORD FLTM AQ 005-01 FORD FLTM EU-AQ 005-01]》.pdf

上传人:dealItalian200 文档编号:746830 上传时间:2019-01-14 格式:PDF 页数:3 大小:26.26KB
下载 相关 举报
FORD FLTM AQ 105-01-2001 DETERMINATION OF CHROMIUM OXIDE COATING WEIGHTS (Replaces FLTM EU-AQ 005-01)《氧化铬涂层重量的测定 替代FLTM EU-AQ 005-01[替代 FORD FLTM AQ 005-01 FORD FLTM EU-AQ 005-01]》.pdf_第1页
第1页 / 共3页
FORD FLTM AQ 105-01-2001 DETERMINATION OF CHROMIUM OXIDE COATING WEIGHTS (Replaces FLTM EU-AQ 005-01)《氧化铬涂层重量的测定 替代FLTM EU-AQ 005-01[替代 FORD FLTM AQ 005-01 FORD FLTM EU-AQ 005-01]》.pdf_第2页
第2页 / 共3页
FORD FLTM AQ 105-01-2001 DETERMINATION OF CHROMIUM OXIDE COATING WEIGHTS (Replaces FLTM EU-AQ 005-01)《氧化铬涂层重量的测定 替代FLTM EU-AQ 005-01[替代 FORD FLTM AQ 005-01 FORD FLTM EU-AQ 005-01]》.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 FORD LABORATORY TEST METHOD AQ 105-01 Date Action Revisions 2001 01 31 Revised Editorial no technical change A. Cockman 2000 04 20 Editorial no technical change A. Cockman 1990 04 10 Printed copies are uncontrolled Page 1 of 3 Copyright 2001, Ford Global Technologies, Inc. DETERMINATION OF CHROMIUM

2、 OXIDE COATING WEIGHTS Application This procedure is used to determine the coating weight of chromium oxide conversion coatings on aluminum parts by testing the coating on aluminum test panels which have been put through the complete cycle of the coating system under test. Materials and Apparatus Re

3、quired Aluminum Panels Made from alloys with the same composition as the aluminum parts which have been put through the coating system. Dimensions: 100 x 300 mm (max 5 mm thick). Laboratory Convection Oven Capable of maintaining a temperature of 100 +/- 2 C. Analytical Balance With an accuracy of 0.

4、1 mg. Desiccator With a suitable desiccant. Ethanol Acetone Tetrachloroethylene Stripper Solution A * FORD LABORATORY TEST METHOD AQ 105-01 Page 2 of 3 Copyright 2001, Ford Global Technologies, Inc. Stripper Solution B * Consisting of 1.2 g chromic acid (C.P.); 480 g Aluminum Nitrate; 300 mL water.

5、Note: Stripper Solution A is to be used for unbaked test panels under 24 hours old. Stripper Solution B is to be used for unbaked test panels over 24 hours old. (Stripper Solution B may not be used for SAE AA2024, Din 1725 AlCuMg2, BS 1470 H15, and SAE AA7075, DIN 1725 AlZnMgCu 1.5 alloys). These al

6、loys must be tested before they are 24 hours old. * Stripping solution must be renewed after twelve test panels have been run. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity

7、 for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. Procedure 1. Process two panels through a complete cycle of the coating system under test which includes cleaning, coating, acid rinse (if required) and drying. 2. Cut four test panels (100 x 10

8、0 mm sections, or other suitable size) from the larger panels. 3. Remove all grease or foreign matter from the 100 mm x 100 mm test panels by washing with tetrachloroethylene, acetone and ethanol. A mixture of these three solvents poured over the test panels should remove any soil. 4. Blot the test

9、panels with a soft cloth and dry in the oven at 100 +/- 2 C for five minutes. 5. Cool in the desiccator and weigh the test panels to the nearest 0.1 mm. 6. Fully immerse each test panel in the appropriate stripping bath. Note: Stripper A - Immerse test panels at 23 +/- 2 C for 2 5 minutes. Stripper

10、B - Immerse test panels at boil for 2.5 5 minutes. 7. Rinse test panel in cold running water (under 27 C, preferably under 16 C). Blot and dry in oven at 100 C. 8. Cool in desiccator and reweigh. Repeat Steps 5, 6 and 7 until a constant weight is obtained. FORD LABORATORY TEST METHOD AQ 105-01 Page

11、3 of 3 Copyright 2001, Ford Global Technologies, Inc. Evaluation Calculate the coating weight in mg per 100 cm2 of surface from the following: W = L x 100 A Where: W = mg of coating per 100 cm2 of surface L = loss in weight, mg A = surface area of test specimen, cm2 (both sides) Chemicals, materials, parts, and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities.

展开阅读全文
相关资源
猜你喜欢
  • DIN EN 61120-3-1994 Digital audio tape recorder reel to reel system using 6 3 mm magnetic tape for professional use part 3 format B (IEC 61120-3 1991) German version EN 61120-3 199.pdf DIN EN 61120-3-1994 Digital audio tape recorder reel to reel system using 6 3 mm magnetic tape for professional use part 3 format B (IEC 61120-3 1991) German version EN 61120-3 199.pdf
  • DIN EN 61120-4-1993 Digital audio tape recorder reel-to-reel system using 6 3 mm magnetic tape for professional use part 4 magnetic tape properties definitions and methods of measu.pdf DIN EN 61120-4-1993 Digital audio tape recorder reel-to-reel system using 6 3 mm magnetic tape for professional use part 4 magnetic tape properties definitions and methods of measu.pdf
  • DIN EN 61120-5-1996 Digital audio tape recorder reel-to-reel system using 6 3 mm magnetic tape for professional use - Part 5 Reels (IEC 61120-5 1995) German version EN 61120-5 1995.pdf DIN EN 61120-5-1996 Digital audio tape recorder reel-to-reel system using 6 3 mm magnetic tape for professional use - Part 5 Reels (IEC 61120-5 1995) German version EN 61120-5 1995.pdf
  • DIN EN 61122-1994 Still video floppy disk magnetic recording system (IEC 61122 1992) German version EN 61122 1993《静止视频软盘磁性录制系统》.pdf DIN EN 61122-1994 Still video floppy disk magnetic recording system (IEC 61122 1992) German version EN 61122 1993《静止视频软盘磁性录制系统》.pdf
  • DIN EN 61124-2013 Reliability testing - Compliance tests for constant failure rate and constant failure intensity (IEC 61124 2012) German version EN 61124 2012《可靠性试验 恒定失效率和恒定失效强度的符.pdf DIN EN 61124-2013 Reliability testing - Compliance tests for constant failure rate and constant failure intensity (IEC 61124 2012) German version EN 61124 2012《可靠性试验 恒定失效率和恒定失效强度的符.pdf
  • DIN EN 61131-1-2004 Programmable controllers - Part 1 General information (IEC 61131-1 2003) German version EN 61131-1 2003《可编程控制器 第1部分 一般资料》.pdf DIN EN 61131-1-2004 Programmable controllers - Part 1 General information (IEC 61131-1 2003) German version EN 61131-1 2003《可编程控制器 第1部分 一般资料》.pdf
  • DIN EN 61131-2-2008 Programmable controllers - Part 2 Equipment requirements and tests (IEC 61131-2 2007) German version EN 61131-2 2007《可编程控制器 第2部分 设备要求和试验(IEC 61131-2-2007)》.pdf DIN EN 61131-2-2008 Programmable controllers - Part 2 Equipment requirements and tests (IEC 61131-2 2007) German version EN 61131-2 2007《可编程控制器 第2部分 设备要求和试验(IEC 61131-2-2007)》.pdf
  • DIN EN 61131-3 Bb 1-2005 Programmable controllers - Guidelines for the application and implementation of programming languages《程序控制器 程序设计语言的应用和执行指南》.pdf DIN EN 61131-3 Bb 1-2005 Programmable controllers - Guidelines for the application and implementation of programming languages《程序控制器 程序设计语言的应用和执行指南》.pdf
  • DIN EN 61131-3-2014 Programmable controllers - Part 3 Programming languages (IEC 61131-3 2013) German version EN 61131-3 2013《可编程控制器 第3部分 程序设计语言》.pdf DIN EN 61131-3-2014 Programmable controllers - Part 3 Programming languages (IEC 61131-3 2013) German version EN 61131-3 2013《可编程控制器 第3部分 程序设计语言》.pdf