FORD FLTM BO 160-04-2017 RESISTANCE OF PAINTED PLASTIC PARTS TO HIGH PRESSURE CLEANING OPERATIONS.pdf

上传人:postpastor181 文档编号:747392 上传时间:2019-01-14 格式:PDF 页数:2 大小:44.04KB
下载 相关 举报
FORD FLTM BO 160-04-2017 RESISTANCE OF PAINTED PLASTIC PARTS TO HIGH PRESSURE CLEANING OPERATIONS.pdf_第1页
第1页 / 共2页
FORD FLTM BO 160-04-2017 RESISTANCE OF PAINTED PLASTIC PARTS TO HIGH PRESSURE CLEANING OPERATIONS.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 FORD LABORATORY TEST METHOD BO 160-04 Date Action Revisions Rev 03 2017 06 09 Editorial Corrected typos L. Soreide, NA 2004 01 30 Revised Revised the settings and procedure section A. Weakly 1992 01 22 Controlled document at www.MATS Copyright 2017, Ford Global Technologies, LLC Page 1 of 2 RESISTA

2、NCE OF PAINTED PLASTIC PARTS TO HIGH PRESSURE CLEANING OPERATIONS Application This procedure defines the test equipment and test method for the resistance of painted plastic parts (e.g., bumper bars, mirror housings, radiator grills) against high pressure cleaning processes. Equipment Required High

3、Pressure Cleaning Equipment: Cleemax Serial 1053 Source: Pearson Panke Equipment Ltd, 1-3, Hale Grove Gardens, London NW7 3LR Great Britain Or equivalent instrument suitable to provide the required temperature, pressure and flow rate of water, with a fixed or moving head. Jet Tpe QVVA 2506 Source Sp

4、raying Systems Company See the website http:/ for the local agent. Or equivalent. Scriber Type: See FLTM BI 106-1 Settings Method A, fixed jet: Jet position Perpendicular to specimen Water temperature, 70 C +/- 2 C Distance of nozzle to specimen 50 mm +/-3 mm Water pressure, 3000 +/-50 kPa Testing t

5、ime 60 seconds, +/- 3 seconds Water flow rate 420 litres/hour minimum FORD LABORATORY TEST METHOD BO 160-04 Copyright 2017, Ford Global Technologies, LLC Page 2 of 2 Method B, moving jet. Jet position Perpendicular to specimen Water Temperature 80 C +/- 4 C Distance of nozzle to specimen 100 mm +/-3

6、 mm Water pressure, 6000 +/-50 kPa Moving range 30 mm +/- 10 mm from center, total traverse 60 mm Moving cycle 60 cycle/minute Moving direction Parallel to the X scribe on the specimen Jet position Perpendicular to specimen (The lines of the X scribe are Northeast to Southwest. The longer axis of th

7、e spray fan pattern is East-West, and the direction of movement is North-South.) Testing time 120 seconds, +/-3 seconds Water flow rate 610 litres/hour minimum Note: The water pressure and water temperature settings must be measured immediately behind the nozzle. Conditioning and Test Conditions All

8、 test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5% relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. Procedure 1. The equipment is filled with water without an

9、y additional cleaning agents and heated. 2. Before testing, the equipment must be adjusted to the required test pressure for the specified distance. 3 Scribe the panel with an X scribe, over the whole area to be exposed to the water jet. 4. The gun with the nozzle is fixed to the required distance f

10、rom the nozzle to the painted surface which is to be tested. The jet of water has to be directed vertically onto the painted surface. 5. Spray water for the specified length of time. 6. The surface is dried and evaluated after cooling to 23 +/- 2 C. 7. Report any failure (e.g., loss of gloss, loss of adhesion, surface deterioration). The principal failure mode is paint peeling. Chemicals, materials, parts, and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities.

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1