FORD FLTM BU 109-02-2007 COLD ADHESION TEST FOR DOUBLE FACED PRESSURE SENSITIVE TAPES TO BE USED WITH FORD WSS-M99P1111-A 《双面压敏胶带的低温粘附力试验 与标准FORD WSS-M99P1111-A一起使用 》.pdf

上传人:amazingpat195 文档编号:747535 上传时间:2019-01-14 格式:PDF 页数:5 大小:90.05KB
下载 相关 举报
FORD FLTM BU 109-02-2007 COLD ADHESION TEST FOR DOUBLE FACED PRESSURE SENSITIVE TAPES  TO BE USED WITH FORD WSS-M99P1111-A  《双面压敏胶带的低温粘附力试验  与标准FORD WSS-M99P1111-A一起使用 》.pdf_第1页
第1页 / 共5页
FORD FLTM BU 109-02-2007 COLD ADHESION TEST FOR DOUBLE FACED PRESSURE SENSITIVE TAPES  TO BE USED WITH FORD WSS-M99P1111-A  《双面压敏胶带的低温粘附力试验  与标准FORD WSS-M99P1111-A一起使用 》.pdf_第2页
第2页 / 共5页
FORD FLTM BU 109-02-2007 COLD ADHESION TEST FOR DOUBLE FACED PRESSURE SENSITIVE TAPES  TO BE USED WITH FORD WSS-M99P1111-A  《双面压敏胶带的低温粘附力试验  与标准FORD WSS-M99P1111-A一起使用 》.pdf_第3页
第3页 / 共5页
FORD FLTM BU 109-02-2007 COLD ADHESION TEST FOR DOUBLE FACED PRESSURE SENSITIVE TAPES  TO BE USED WITH FORD WSS-M99P1111-A  《双面压敏胶带的低温粘附力试验  与标准FORD WSS-M99P1111-A一起使用 》.pdf_第4页
第4页 / 共5页
FORD FLTM BU 109-02-2007 COLD ADHESION TEST FOR DOUBLE FACED PRESSURE SENSITIVE TAPES  TO BE USED WITH FORD WSS-M99P1111-A  《双面压敏胶带的低温粘附力试验  与标准FORD WSS-M99P1111-A一起使用 》.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 FORD LABORATORY TEST METHODBU 109-02Date Action Revisions 2007 05 08 Revised Revised Cold Box, Foam Damper, Procedure #3 and updated the Modified Cold Slam Fixture (Figure 5) M. Mehandru 2000 11 09 Editorial no technical change A. Cockman 1992 11 02 Printed copies are uncontrolled Copyright 2007, F

2、ord Global Technologies, LLC Page 1 of 5 COLD ADHESION TEST FOR DOUBLE FACED PRESSURE SENSITIVE TAPES Application These procedures are used to determine the adhesion properties of double faced pressure sensitive tapes when subjected to impact at a low temperature. Apparatus Required Slamming Fixture

3、 The slamming fixture shown in the attached sketch (Figure 1) is used to deliver a uniform impact to the test panels. Contact area of the panel during slamming test is 12.5 mm on each side and bottom edge of the panel (Figure 5). Cold Box The cold box shall be large enough to accommodate the fixture

4、 during the slamming test. The box shall be capable of maintaining a temperature of -30 C. Test Bars The test bar material is a molding and extrusion grade of polyvinyl chloride with a durometer “A“ hardness of 96 (Figure 2). Source: Standard Products Company 2401 South Gulley Rd Dearborn, Michigan

5、Foam Damper The foam damper material is a 3-900 C, 9.5 mm thick. Source: Illbruck Foamtec, Inc. 3800 Washington Avenue N Minneapolis, MN 55412 Steel Panels The panels used in this test shall be the following: Support panel 300 x 300 x 0.9 mm cold rolled steel painted or primed. Test panel 100 x 300

6、x 0.9 mm cold rolled steel painted per ESB-M4P4-A using approved production materials or substrate systems as specified. Roller Roller described in ASTM D 1000 and modified by the addition of weights to obtain a total roller weight of 6.8 kg. FORD LABORATORY TEST METHODBU 109-02Printed copies are un

7、controlled Copyright 2007, Ford Global Technologies, LLC Page 2 of 5 Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under

8、the same conditions unless otherwise specified. Procedure 1. Tape Sample Preparation for Tape Requirements Samples shall be applied to all substrates that have been cleaned with a 50/50 solution of distilled water and isopropyl alcohol (including test bars) by rolling once forward and once backward

9、for the full length of the tape with a roller described in ASTM D 1000. The roller shall be modified by the addition of weights to obtain a total roller weight of 6.8 kg. The roller speed shall be 50 mm/s. A 6.8 kg load shall be applied for approximately 3 s on bonded assemblies. 2. Test Bar Prepara

10、tion (Test Bars described in Figure 2) Apply primer (Norton Tite-R-Bond, No. 2287) to the 12.7 mm side of test bar. Allow to dry for 5 minutes. Apply the non-liner side of the tape to the primer coated side of the test bar. Roll as described in para 1. 3. Test Bar Preparation (Painted Panels) Apply

11、four 12.7 x 75 mm test bars as described in Figure 2, on a freshly baked painted panel (100 x 300 x 0.9 mm) per ESB-M2P4-A and equally spaced. 4. Condition the bonded assembly for 72h at 23 +/- 2 C. 5. Place the panel and the slamming fixture in a cold box maintained at -29 C for a minimum of 4 h. 6

12、 Insert the 100 x 300 x 0.9 painted steel panel with the test bars to the 300 x 300 x 0.9 steel panel by means of attachment. See Figure 4. 7. Raise the two slamming panels to the 90 degree level position and release. 8. Allow the panel to strike the fixture once. Perform the slam 10 times in rapid

13、 succession. 9. Observe whether any of the test bars have fallen off. 10. Note the mode failure. Chemicals, materials, parts, and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities. FORD LABORAT

14、ORY TEST METHODBU 109-02Printed copies are uncontrolled Copyright 2007, Ford Global Technologies, LLC Page 3 of 5 COLD ADHESION TEST FIGURE 1 ALL DIMENSIONS IN mm DETAILED VIEW OF SLAMMING FIXTURE FOR COLD ADHESHION TEST FORD LABORATORY TEST METHODBU 109-02Printed copies are uncontrolled Copyright 2

15、007, Ford Global Technologies, LLC Page 4 of 5 COLD ADHESION TEST FOR DOUBLE FACED PRESSURE SENSITIVE TAPES ALL DIMENSIONS IN mm FIGURE 2 FIGURE 3 FORD LABORATORY TEST METHODBU 109-02Printed copies are uncontrolled Copyright 2007, Ford Global Technologies, LLC Page 5 of 5 COLD ADHESION TEST FIGURE 4 ALL DIMENSIONS IN mm FIGURE 5

展开阅读全文
相关资源
猜你喜欢
  • BS EN 868-10-2009 Packaging for terminally sterilized medical devices - Adhesive coated nonwoven materials of polyolefines - Requirements and test methods《最终灭菌医疗器械的包装 聚烯烃粘性涂覆非织物材料 .pdf BS EN 868-10-2009 Packaging for terminally sterilized medical devices - Adhesive coated nonwoven materials of polyolefines - Requirements and test methods《最终灭菌医疗器械的包装 聚烯烃粘性涂覆非织物材料 .pdf
  • BS EN 868-2-2017 Packaging for terminally sterilized medical devices Sterilization wrap Requirements and test methods《最终灭菌医疗器械的包装 灭菌套 试验方法和要求》.pdf BS EN 868-2-2017 Packaging for terminally sterilized medical devices Sterilization wrap Requirements and test methods《最终灭菌医疗器械的包装 灭菌套 试验方法和要求》.pdf
  • BS EN 868-3-2017 Packaging for terminally sterilized medical devices Paper for use in the manufacture of paper bags (specified in EN 868-4) and in the manufacture of pouches and re.pdf BS EN 868-3-2017 Packaging for terminally sterilized medical devices Paper for use in the manufacture of paper bags (specified in EN 868-4) and in the manufacture of pouches and re.pdf
  • BS EN 868-4-2017 Packaging for terminally sterilized medical devices Paper bags Requirements and test methods《最终灭菌医疗器械的包装 纸袋 试验方法和要求》.pdf BS EN 868-4-2017 Packaging for terminally sterilized medical devices Paper bags Requirements and test methods《最终灭菌医疗器械的包装 纸袋 试验方法和要求》.pdf
  • BS EN 868-5-2009 Packaging for terminally sterilized medical devices - Sealable pouches and reels of porous and plastic film construction - Requirements and test methods《最终灭菌医疗器械的包.pdf BS EN 868-5-2009 Packaging for terminally sterilized medical devices - Sealable pouches and reels of porous and plastic film construction - Requirements and test methods《最终灭菌医疗器械的包.pdf
  • BS EN 868-6-2017 Packaging for terminally sterilized medical devices Paper for low temperature sterilization processes Requirements and test methods《最终灭菌医疗器械的包装 低温灭菌处理用纸 试验方法和要求》.pdf BS EN 868-6-2017 Packaging for terminally sterilized medical devices Paper for low temperature sterilization processes Requirements and test methods《最终灭菌医疗器械的包装 低温灭菌处理用纸 试验方法和要求》.pdf
  • BS EN 868-7-2017 Packaging for terminally sterilized medical devices Adhesive coated paper for low temperature sterilization processes Requirements and test methods《最终灭菌医疗器械的包装 低温消.pdf BS EN 868-7-2017 Packaging for terminally sterilized medical devices Adhesive coated paper for low temperature sterilization processes Requirements and test methods《最终灭菌医疗器械的包装 低温消.pdf
  • BS EN 868-8-2009 Packaging for terminally sterilized medical devices - Re-usable sterilization containers for steam sterilizers conforming to EN 285 Requirements and test methods《最.pdf BS EN 868-8-2009 Packaging for terminally sterilized medical devices - Re-usable sterilization containers for steam sterilizers conforming to EN 285 Requirements and test methods《最.pdf
  • BS EN 868-9-2009 Packaging for terminally sterilized medical devices - Uncoated nonwoven materials of polyolefines - Requirements and test methods《最终灭菌医疗器械的包装 聚烯烃非包覆非织物材料 试验方法和要求》.pdf BS EN 868-9-2009 Packaging for terminally sterilized medical devices - Uncoated nonwoven materials of polyolefines - Requirements and test methods《最终灭菌医疗器械的包装 聚烯烃非包覆非织物材料 试验方法和要求》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有