FORD FLTM EU-BO 060-01-2001 HYDROLYSIS RESISTANCE OF THERMOPLASTIC MOULDING COMPOUNDS (EXTRACTION-HYDROLYSIS-OXIDATION TEST EHO-TEST)《热塑性成型料的耐水解性(提取-水解-氧化试验 EHO试验)》.pdf

上传人:wealthynice100 文档编号:747834 上传时间:2019-01-14 格式:PDF 页数:2 大小:29.07KB
下载 相关 举报
FORD FLTM EU-BO 060-01-2001 HYDROLYSIS RESISTANCE OF THERMOPLASTIC MOULDING COMPOUNDS (EXTRACTION-HYDROLYSIS-OXIDATION TEST EHO-TEST)《热塑性成型料的耐水解性(提取-水解-氧化试验 EHO试验)》.pdf_第1页
第1页 / 共2页
FORD FLTM EU-BO 060-01-2001 HYDROLYSIS RESISTANCE OF THERMOPLASTIC MOULDING COMPOUNDS (EXTRACTION-HYDROLYSIS-OXIDATION TEST EHO-TEST)《热塑性成型料的耐水解性(提取-水解-氧化试验 EHO试验)》.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 FORD LABORATORY TEST METHOD EU-BO 060-01 Date Action Revisions 2001 03 28 Revised Editorial no technical change A. Cockman 1994 02 28 Printed copies are uncontrolled Page 1 of 2 Copyright 2001, Ford Global Technologies, Inc. HYDROLYSIS RESISTANCE OF THERMOPLASTIC MOULDING COMPOUNDS (EXTRACTION-HYDR

2、OLYSIS-OXIDATION TEST, EHO-TEST) Application This method is used to determine the hydrolysis resistance of thermoplastic moulding compounds on test specimens. It is suitable to distinguish stabilized materials from non-stabilized materials. The test is provided for use at the suppliers on the develo

3、pment of new stabilized thermoplastic moulding compounds. Equipment Required Autoclave (Volume of 5 litres and sieve insert) The tank must be equipped with thermostatic control and must be capable to maintain a temperature of 118 +/- 2 C over 24 hours. It must have 2 entries for air and water steam

4、and 2 exits for condensing water and to atmosphere. Air Supply Capacity of 56 1/minute at a temperature of 118 +/- 5 C. Steam Generator/Supply 1.9 bar Tensile Testing Machine With elongation indicator. Water Tank Test Specimens Tests shall be carried out on injection moulded specimens for tensile pr

5、operties according to ISO R527, Type 1. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless ot

6、herwise specified. FORD LABORATORY TEST METHOD EU-BO 060-01 Page 2 of 2 Copyright 2001, Ford Global Technologies, Inc. Procedure The autoclave is to be heated up to 118 +/- 2 C. 20 test specimens are to be positioned on the sieve mounted in the test cabinet. The tank must be closed tightly. The stea

7、m supply is to be set at 1.9 bar. The supplied air shall be heated to 118 +/- 5 C and the flow set at 56 1/minute. After ageing of 24 hours, 10 specimens are to be picked up for tensile testing according to ISO R527. They shall be cooled in a water tank at 23 +/- 2 C, and within 1 hour after removal

8、 from the water tank the yield point is tested under standardized atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity. The test speed is adjusted according to the requirement of the specification. The average value from the 10 specimens has to be considered as original value. After further age

9、ing of 96 hours at 118 +/- 2 C and 56 1/minute air flow rate the other 10 specimens are to be removed and cooled and tested as mentioned above. The average of these 10 specimens will be used for the calculation. Evaluation According to ISO R527 and engineering material specification the percentage d

10、ecrease of yield point is reported. Determination of yield point: (a) Original value: GS (b) Value after 96 hours: GS 96 Percentage decrease of yield point: 100 - 100 G S 96 (%) GS Chemicals, materials, parts, and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities.

展开阅读全文
相关资源
猜你喜欢
  • ETSI EN 300 132-3-0-2012 Environmental Engineering (EE) Power supply interface at the input to telecommunications and datacom (ICT) equipment Part 3 Operated by rectified current s.pdf ETSI EN 300 132-3-0-2012 Environmental Engineering (EE) Power supply interface at the input to telecommunications and datacom (ICT) equipment Part 3 Operated by rectified current s.pdf
  • ETSI EN 300 132-3-0-2012 Environmental Engineering (EE) Power supply interface at the input to telecommunications and datacom (ICT) equipment Part 3 Operated by rectified current s_1.pdf ETSI EN 300 132-3-0-2012 Environmental Engineering (EE) Power supply interface at the input to telecommunications and datacom (ICT) equipment Part 3 Operated by rectified current s_1.pdf
  • ETSI EN 300 132-3-1-2012 Environmental Engineering (EE) Power supply interface at the input to telecommunications and datacom (ICT) equipment Part 3 Operated by rectified current s.pdf ETSI EN 300 132-3-1-2012 Environmental Engineering (EE) Power supply interface at the input to telecommunications and datacom (ICT) equipment Part 3 Operated by rectified current s.pdf
  • ETSI EN 300 132-3-1-2012 Environmental Engineering (EE) Power supply interface at the input to telecommunications and datacom (ICT) equipment Part 3 Operated by rectified current s_1.pdf ETSI EN 300 132-3-1-2012 Environmental Engineering (EE) Power supply interface at the input to telecommunications and datacom (ICT) equipment Part 3 Operated by rectified current s_1.pdf
  • ETSI EN 300 132-3-2003 Environmental Engineering (EE) Power supply interface at the input to telecommunications equipment Part 3 Operated by rectified current source alternating cu.pdf ETSI EN 300 132-3-2003 Environmental Engineering (EE) Power supply interface at the input to telecommunications equipment Part 3 Operated by rectified current source alternating cu.pdf
  • ETSI EN 300 132-3-2003 Environmental Engineering (EE) Power supply interface at the input to telecommunications equipment Part 3 Operated by rectified current source alternating cu_1.pdf ETSI EN 300 132-3-2003 Environmental Engineering (EE) Power supply interface at the input to telecommunications equipment Part 3 Operated by rectified current source alternating cu_1.pdf
  • ETSI EN 300 135-1-2008 Electromagnetic compatibility and Radio spectrum Matters (ERM) Land Mobile Service Citizens- Band (CB) radio equipment Angle-modulated Citizens- Band radio e.pdf ETSI EN 300 135-1-2008 Electromagnetic compatibility and Radio spectrum Matters (ERM) Land Mobile Service Citizens- Band (CB) radio equipment Angle-modulated Citizens- Band radio e.pdf
  • ETSI EN 300 135-1-2008 Electromagnetic compatibility and Radio spectrum Matters (ERM) Land Mobile Service Citizens- Band (CB) radio equipment Angle-modulated Citizens- Band radio e_1.pdf ETSI EN 300 135-1-2008 Electromagnetic compatibility and Radio spectrum Matters (ERM) Land Mobile Service Citizens- Band (CB) radio equipment Angle-modulated Citizens- Band radio e_1.pdf
  • ETSI EN 300 138-1-1998 Integrated Services Digital Network (ISDN) Closed User Group (CUG) Supplementary Service Digital Subscriber Signalling System No One (DSS1) Protocol Part 1 P.pdf ETSI EN 300 138-1-1998 Integrated Services Digital Network (ISDN) Closed User Group (CUG) Supplementary Service Digital Subscriber Signalling System No One (DSS1) Protocol Part 1 P.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1