FORD FLTM EU-BV 054-04-2000 ADHESION OF SOUND DEADENER SHEETS AND PADS《隔音板和衬垫的粘附力》.pdf

上传人:王申宇 文档编号:747873 上传时间:2019-01-14 格式:PDF 页数:4 大小:45.65KB
下载 相关 举报
FORD FLTM EU-BV 054-04-2000 ADHESION OF SOUND DEADENER SHEETS AND PADS《隔音板和衬垫的粘附力》.pdf_第1页
第1页 / 共4页
FORD FLTM EU-BV 054-04-2000 ADHESION OF SOUND DEADENER SHEETS AND PADS《隔音板和衬垫的粘附力》.pdf_第2页
第2页 / 共4页
FORD FLTM EU-BV 054-04-2000 ADHESION OF SOUND DEADENER SHEETS AND PADS《隔音板和衬垫的粘附力》.pdf_第3页
第3页 / 共4页
FORD FLTM EU-BV 054-04-2000 ADHESION OF SOUND DEADENER SHEETS AND PADS《隔音板和衬垫的粘附力》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 FORD LABORATORY TEST METHOD EU-BV 054-04 Date Action Revisions 2000 11 14 Revised Editorial no technical change A. Cockman 1994 02 28 Printed copies are uncontrolled Page 1 of 4 Copyright 2000, Ford Global Technologies, Inc. ADHESION OF SOUND DEADENER SHEETS AND PADS Application This method is used

2、 to determine the adhesion strength of Sound Deadener sheets and pads. Method A: For self-adhering pads and sheets. Method B: For heat-fusible pads and sheets. Apparatus Required Test Panels (see drawing) Steel Body Skin Panels, surface roughness 0.9 - 1.8 micrometre C.L.A. Dimensions: Upper Panel 6

3、0 x 50 x 0.8 mm Lower Panel 60 x 65 x 0.8 mm Preparation: Freshly prepared as required by the relevant Materials Specification as follows: Type I: Oiled surface according to FLTM EU-BV 50-11 - Normal Grade. Type II: Electrocoated surface prepared according to the technique outlined in FLTM EU-BI 20-

4、1, using a released material. Alternatively, panels can be electrocoated in the normal production process. Mechanical Convection Oven Capable of maintaining temperatures up to 250 C within 2 C. Tensile Machine With a constant rate of jaw separation of 25 mm/minute and an autographic recording device

5、 Test Fixture See Drawing 3. Silicone Paper Strips 25 mm wide and 60 mm long. FORD LABORATORY TEST METHOD EU-BV 054-04 Page 2 of 4 Copyright 2000, Ford Global Technologies, Inc. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmos

6、phere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. Preparation of Test Assembly 1. Prepare the test assembly according to drawing 1 using the 2 test panels inserting the strip of silicone paper

7、 as shown in drawing. 2. The pretreatment of the panels must be as required by the relevant Material Specification, either as: Type I - Oiled surfaces or Type II - Electrocoated surfaces 3. The adhesion of the material under test to the panels is achieved: Method A: For self-adhering pads - by hand

8、pressure at 23 +/- 2 C. Method B: For heat-fusible pads - by heating to the temperature specified in the relevant Material Specification. Procedure Note: 3 test assemblies required unless otherwise specified. 1. After preparation according to Method A or B, condition test assemblies for 2 h at 23 +/

9、 2 C. 2. Fit the test assembly into the fixture as shown in drawing 2 and test for adhesion strength in the tensile machine at a jaw separation rate of 25 mm/ minute. Evaluation Calculate the adhesion strength as follows: Adhesion Strength (kgf/cm) = Maximum load (kgf) Width of material under test

10、cm) All test assemblies must meet the maximum requirements of the Specification. Chemicals, materials, parts, and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities. FORD LABORATORY TEST METHOD EU-BV 054-04 Page 3 of 4 Copyright 2000, Ford Global Technologies, Inc. ADHESION OF SOUND DEADENER SHEETS AND PADS FORD LABORATORY TEST METHOD EU-BV 054-04 Page 4 of 4 Copyright 2000, Ford Global Technologies, Inc. ADHESION OF SOUND DEADENER SHEETS AND PADS

展开阅读全文
相关资源
猜你喜欢
  • DIN 49075-2-1989 de 6641 Cover plates for use with switches socket-outlets and other accessories intended to be mounted into mounting boxes with openings other than of diameter 45 .pdf DIN 49075-2-1989 de 6641 Cover plates for use with switches socket-outlets and other accessories intended to be mounted into mounting boxes with openings other than of diameter 45 .pdf
  • DIN 49076-1989 Openings in front covers of ducting and trunking for use with switches socket-outlets and other accessories to be mounted into mounting boxes main dimensions《与转换开关、插.pdf DIN 49076-1989 Openings in front covers of ducting and trunking for use with switches socket-outlets and other accessories to be mounted into mounting boxes main dimensions《与转换开关、插.pdf
  • DIN 49100-1987 Base for two-pole socket-outlets with earthing contacts 10 A 250 V d c  16 A 250 V a c and switches up to 16 A 250 V mounting dimensions《带直流10A 250V、交流16A250V接地触点和16.pdf DIN 49100-1987 Base for two-pole socket-outlets with earthing contacts 10 A 250 V d c 16 A 250 V a c and switches up to 16 A 250 V mounting dimensions《带直流10A 250V、交流16A250V接地触点和16.pdf
  • DIN 4918-2017 Seamless casings with threaded connections for cased bore-holes《下套管钻孔的螺纹连接无缝外壳》.pdf DIN 4918-2017 Seamless casings with threaded connections for cased bore-holes《下套管钻孔的螺纹连接无缝外壳》.pdf
  • DIN 49200-1987 Switches up to 16 A 250 V for flush and surface mounting《镶入安装和表面安装用250V 16A以下的开关》.pdf DIN 49200-1987 Switches up to 16 A 250 V for flush and surface mounting《镶入安装和表面安装用250V 16A以下的开关》.pdf
  • DIN 4922-1-1978 Steel Filter Pipes for Drilled Wells with Slot Perforation and Fisching (Butt Strap Joint)《带开槽搭接孔和鱼尾板连接的钻井用钢制滤管》.pdf DIN 4922-1-1978 Steel Filter Pipes for Drilled Wells with Slot Perforation and Fisching (Butt Strap Joint)《带开槽搭接孔和鱼尾板连接的钻井用钢制滤管》.pdf
  • DIN 4922-2-1981 Steel Filter Pipes for Drilled Wells with Screwed Connection DN 100 to DN 500《钻井用钢过滤器 螺纹连接 DN100至DN500》.pdf DIN 4922-2-1981 Steel Filter Pipes for Drilled Wells with Screwed Connection DN 100 to DN 500《钻井用钢过滤器 螺纹连接 DN100至DN500》.pdf
  • DIN 4922-3-1975 Steel Filter Pipes for Drilled Wells Flanged Connection NW 500 to NW 1000 (Nominal Diameter 500 to 1000)《钻井用钢滤管 法兰连接 公称直径500至1000》.pdf DIN 4922-3-1975 Steel Filter Pipes for Drilled Wells Flanged Connection NW 500 to NW 1000 (Nominal Diameter 500 to 1000)《钻井用钢滤管 法兰连接 公称直径500至1000》.pdf
  • DIN 4922-4-1999 Steel filter pipes for drilled wells - Part 4 With tension proof socket joint DN 100 to DN 500《钻井用钢滤管 第4部分 DN 100至DN 500抗拉插接套管连接件》.pdf DIN 4922-4-1999 Steel filter pipes for drilled wells - Part 4 With tension proof socket joint DN 100 to DN 500《钻井用钢滤管 第4部分 DN 100至DN 500抗拉插接套管连接件》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1