1、 NON-PRODUCTION mTERIAL SPECIFICATION Date 1991 o9 Material Name Specification Number Action Revis i on s FIRE RETARDANT PAINT M-5J100A 1. SCOPE: The materials desired under this standard are intumescent paints which are actively fire-retardant; will not support combustion, retard the spread of lame

2、s, and actively insulate the painted surfaces against the transmission of heat. M-313F - Factory Dado Green M-5J65F - Medium Green Office Trim M-434F - White Fume Proof M-5J66F - Light Beige Office M-5J79F - Factory Medium Green M-5J67F - Medium Beige OFfice Trim M-454F - Office Green Flat M-5J99AF

3、 Light Gray Office M-5J64F - Light Green Office M-5J99BF - Medium Gray Employee Office 2. APPLICATION: These paints may be brushed, rolled, or sprayed and are generally used on all wood or other combustible material used in interior- construction where fire resistance is required. Paint must be app

4、lied NO THINNER THAN 150 SQUARE FEET PER GALLON. 3. REQUIREMENTS: 3.1 COLOR: (FLTM BI 109-01) The colors shall have the following nominal tristimulus values +/-0.596: C.I.E. Tristimulus Values X Y Z X Y Z M-313F 0.2473 0.2880 0.2279 M-5J65F 0.3296 0.2970 0.2744 M-434F 0.8149 0.8415 0.8498 M-5J66F 0.

5、4724 0.6083 0.4582 M-5J79F 0.4586 0.4459 0.3286 M-5J67F 0.4357 0.4696 0.3484 M-454F 0.5846 0.5820 0.4696 M-5J99AF 0.5869 0.6130 0.5699 M-5J64F 0.4471 0.4037 0.3738 M-5J99BF 0.4682 0.4910 0.4732 3.2 COLOR TOLERANCE: (ASTM D E97) The color shall not differ from the master paint standard by more than 1

6、5 N.B.S. units (Federal Specification TT-P-141, Method 623.1). The luminous directional reflectance shall not differ from the master paint standard by more than +/- 3% (ASTM D 771). NON-PRODUCTION mTERIAL SPECIFICATION M-5J100A 3.3 3.4 3.5 3.6 3.6.1 3.6.2 3.7 3.8 3.9 3.10 3.11 NONVOLATILE: 60.6% mi

7、n (FLTM BI 21) VEHICLE: The vehicle shall exhibit intumescence properties when heated to 300 F (150 C). VISCOSITY: 80 F (27 C) 7885 KU (ASTM D 562) HIDING POWER: WET HIDING: 16 max with 0.0007 wedge (FLTM BI 11) DRY HIDING: The dry hiding power calculated as a contrast ratio shall not be less than 0

8、950 at a film thickness of 1.5 - 2.0 mils. SHELF STABILITY: There shall be no hard settling, skinning, or jellying after aging a one-half full pint can for ten days at room temperature. DRYING: The material shall dry tack free within one hour. It shall have complete drying in 12 hours, at a film th

9、ickness of 1.5 - 2.0 mils, and shall show satisfactory adhesion and film hardness after 48 hours, as determined by shop trial. APPLICATION: The material shall show easy brushing, good flowing, spreading, and leveling properties. A paint that has any noticeable pull under a large wall brush and that

10、shows only fair spreading and flowing properties shall not be acceptable. In addition, this material must be suitable for spraying applications when reduced with M14J242, Toluol, or M14J245, Xylol; these materials must be suitable for use with M6J139A/B, when applied to steel surfaces and M5J35, Whi

11、te Undercoater, when applied to wood surfaces. The fore- going to be determined by shop trial. DURABILITY: This material shall withstand washings and resistance to leaching, as covered in D.O.D. Specification TT-P-O026B, latest edit ion. CLEANING PROPERTIES: The material shall wash clean from brushe

12、s and equipment when M14J242, Toluol, or M14J245, Xylol, is used. There shall be no precipitation or gummy residue left on the brushes or in the equipment after proper cleaning. Page 2 of 3 NON-PRODUCTION mTERIAL SPECIFICATION M-5J100A 3.12 APPROVAL: This material must be listed and classified by th

13、e Underwriters Laboratories, Inc. with fire hazard classifications as below. The fire hazard classification is derived in comparison with upcoated red oak as 100. Each container shall bear the Underwriters Laboratories, Inc. official label certifying these classifications. Fire Hazard Classification

14、 100 Sq. Ft. 150 Sq. Ft. 175 Sq.Ft. Per Gal. Over Per Gal. Over Per Gal. Over Unpr imed Unpr imed Unpr imed Douglas Fir Douglas Fir Douglas Fir in two coats in two coats in two coats See Note (1) See Note (1) Flame Fuel contributed Smoke developed 10 15 5 15 15 5 20 20-25 0-5 4. STANDARD PARAGRAPHS: The following Standard Paragraphs as defined in Manufacturing Standard MJX are herewith made a part of this Standard: P1, P2,P3, R1, R2. Page 3 of 3

展开阅读全文
相关资源
猜你喜欢
  • DIN EN 61631-2002 Test method for the mechanical strength of cores made of magnetic oxides (IEC 61631 2001) German version EN 61631 2001《磁氧化物制磁心的机械强度的试验方法》.pdf DIN EN 61631-2002 Test method for the mechanical strength of cores made of magnetic oxides (IEC 61631 2001) German version EN 61631 2001《磁氧化物制磁心的机械强度的试验方法》.pdf
  • DIN EN 61643-11-2013 Low-voltage surge protective devices - Part 11 Surge protective devices connected to low-voltage power systems - Requirements and test methods (IEC 61643-11 20.pdf DIN EN 61643-11-2013 Low-voltage surge protective devices - Part 11 Surge protective devices connected to low-voltage power systems - Requirements and test methods (IEC 61643-11 20.pdf
  • DIN EN 61643-21-2013 Low voltage surge protective devices - Part 21 Surge protective devices connected to telecommunications and signalling networks - Performance requirements and .pdf DIN EN 61643-21-2013 Low voltage surge protective devices - Part 21 Surge protective devices connected to telecommunications and signalling networks - Performance requirements and .pdf
  • DIN EN 61643-321-2003 Components for low-voltage surge protection devices - Part 321 Specifications for avalanche breakdown diodes (ABD) (IEC 61643-321 2001) German version EN 6164.pdf DIN EN 61643-321-2003 Components for low-voltage surge protection devices - Part 321 Specifications for avalanche breakdown diodes (ABD) (IEC 61643-321 2001) German version EN 6164.pdf
  • DIN EN 61643-331-2004 Components for low-voltage surge protective devices - Part 331 Specification for metal oxide varistors (MOV) (IEC 61643-331 2003) German version EN 61643-331 .pdf DIN EN 61643-331-2004 Components for low-voltage surge protective devices - Part 331 Specification for metal oxide varistors (MOV) (IEC 61643-331 2003) German version EN 61643-331 .pdf
  • DIN EN 61643-341-2002 Components for low-voltage surge protection devices - Part 341 Specification for thyristor surge suppressors (TSS) (IEC 61643-341 2001) German version EN 6164.pdf DIN EN 61643-341-2002 Components for low-voltage surge protection devices - Part 341 Specification for thyristor surge suppressors (TSS) (IEC 61643-341 2001) German version EN 6164.pdf
  • DIN EN 61649-2009 Weibull analysis (IEC 61649 2008) German version EN 61649 2008《魏布尔分析》.pdf DIN EN 61649-2009 Weibull analysis (IEC 61649 2008) German version EN 61649 2008《魏布尔分析》.pdf
  • DIN EN 61663-1-2000 Lightning protection - Telecommunication lines - Part 1 Fibre optic installations (IEC 61663-1 1999 + Corrigendum 1999) German version EN 61663-1 1999《雷电防护 通信线路.pdf DIN EN 61663-1-2000 Lightning protection - Telecommunication lines - Part 1 Fibre optic installations (IEC 61663-1 1999 + Corrigendum 1999) German version EN 61663-1 1999《雷电防护 通信线路.pdf
  • DIN EN 61666-2011 Industrial systems installations and equipment and industrial products - Identification of terminals within a system (IEC 61666 2010) German version EN 61666 2010.pdf DIN EN 61666-2011 Industrial systems installations and equipment and industrial products - Identification of terminals within a system (IEC 61666 2010) German version EN 61666 2010.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1