FORD M5J65F-1991 FIRE RETARDANT PAINT (Shown on M5J100-A SEE SCOPE)《防火漆 列于标准M5J100-A上参见范围》.pdf

上传人:registerpick115 文档编号:747979 上传时间:2019-01-14 格式:PDF 页数:3 大小:114KB
下载 相关 举报
FORD M5J65F-1991 FIRE RETARDANT PAINT (Shown on M5J100-A SEE SCOPE)《防火漆 列于标准M5J100-A上参见范围》.pdf_第1页
第1页 / 共3页
FORD M5J65F-1991 FIRE RETARDANT PAINT (Shown on M5J100-A SEE SCOPE)《防火漆 列于标准M5J100-A上参见范围》.pdf_第2页
第2页 / 共3页
FORD M5J65F-1991 FIRE RETARDANT PAINT (Shown on M5J100-A SEE SCOPE)《防火漆 列于标准M5J100-A上参见范围》.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 NON-PRODUCTION mTERIAL SPECIFICATION Date 1991 o9 Material Name Specification Number Action Revis i on s FIRE RETARDANT PAINT M-5J100A 1. SCOPE: The materials desired under this standard are intumescent paints which are actively fire-retardant; will not support combustion, retard the spread of lame

2、s, and actively insulate the painted surfaces against the transmission of heat. M-313F - Factory Dado Green M-5J65F - Medium Green Office Trim M-434F - White Fume Proof M-5J66F - Light Beige Office M-5J79F - Factory Medium Green M-5J67F - Medium Beige OFfice Trim M-454F - Office Green Flat M-5J99AF

3、 Light Gray Office M-5J64F - Light Green Office M-5J99BF - Medium Gray Employee Office 2. APPLICATION: These paints may be brushed, rolled, or sprayed and are generally used on all wood or other combustible material used in interior- construction where fire resistance is required. Paint must be app

4、lied NO THINNER THAN 150 SQUARE FEET PER GALLON. 3. REQUIREMENTS: 3.1 COLOR: (FLTM BI 109-01) The colors shall have the following nominal tristimulus values +/-0.596: C.I.E. Tristimulus Values X Y Z X Y Z M-313F 0.2473 0.2880 0.2279 M-5J65F 0.3296 0.2970 0.2744 M-434F 0.8149 0.8415 0.8498 M-5J66F 0.

5、4724 0.6083 0.4582 M-5J79F 0.4586 0.4459 0.3286 M-5J67F 0.4357 0.4696 0.3484 M-454F 0.5846 0.5820 0.4696 M-5J99AF 0.5869 0.6130 0.5699 M-5J64F 0.4471 0.4037 0.3738 M-5J99BF 0.4682 0.4910 0.4732 3.2 COLOR TOLERANCE: (ASTM D E97) The color shall not differ from the master paint standard by more than 1

6、5 N.B.S. units (Federal Specification TT-P-141, Method 623.1). The luminous directional reflectance shall not differ from the master paint standard by more than +/- 3% (ASTM D 771). NON-PRODUCTION mTERIAL SPECIFICATION M-5J100A 3.3 3.4 3.5 3.6 3.6.1 3.6.2 3.7 3.8 3.9 3.10 3.11 NONVOLATILE: 60.6% mi

7、n (FLTM BI 21) VEHICLE: The vehicle shall exhibit intumescence properties when heated to 300 F (150 C). VISCOSITY: 80 F (27 C) 7885 KU (ASTM D 562) HIDING POWER: WET HIDING: 16 max with 0.0007 wedge (FLTM BI 11) DRY HIDING: The dry hiding power calculated as a contrast ratio shall not be less than 0

8、950 at a film thickness of 1.5 - 2.0 mils. SHELF STABILITY: There shall be no hard settling, skinning, or jellying after aging a one-half full pint can for ten days at room temperature. DRYING: The material shall dry tack free within one hour. It shall have complete drying in 12 hours, at a film th

9、ickness of 1.5 - 2.0 mils, and shall show satisfactory adhesion and film hardness after 48 hours, as determined by shop trial. APPLICATION: The material shall show easy brushing, good flowing, spreading, and leveling properties. A paint that has any noticeable pull under a large wall brush and that

10、shows only fair spreading and flowing properties shall not be acceptable. In addition, this material must be suitable for spraying applications when reduced with M14J242, Toluol, or M14J245, Xylol; these materials must be suitable for use with M6J139A/B, when applied to steel surfaces and M5J35, Whi

11、te Undercoater, when applied to wood surfaces. The fore- going to be determined by shop trial. DURABILITY: This material shall withstand washings and resistance to leaching, as covered in D.O.D. Specification TT-P-O026B, latest edit ion. CLEANING PROPERTIES: The material shall wash clean from brushe

12、s and equipment when M14J242, Toluol, or M14J245, Xylol, is used. There shall be no precipitation or gummy residue left on the brushes or in the equipment after proper cleaning. Page 2 of 3 NON-PRODUCTION mTERIAL SPECIFICATION M-5J100A 3.12 APPROVAL: This material must be listed and classified by th

13、e Underwriters Laboratories, Inc. with fire hazard classifications as below. The fire hazard classification is derived in comparison with upcoated red oak as 100. Each container shall bear the Underwriters Laboratories, Inc. official label certifying these classifications. Fire Hazard Classification

14、 100 Sq. Ft. 150 Sq. Ft. 175 Sq.Ft. Per Gal. Over Per Gal. Over Per Gal. Over Unpr imed Unpr imed Unpr imed Douglas Fir Douglas Fir Douglas Fir in two coats in two coats in two coats See Note (1) See Note (1) Flame Fuel contributed Smoke developed 10 15 5 15 15 5 20 20-25 0-5 4. STANDARD PARAGRAPHS: The following Standard Paragraphs as defined in Manufacturing Standard MJX are herewith made a part of this Standard: P1, P2,P3, R1, R2. Page 3 of 3

展开阅读全文
相关资源
猜你喜欢
  • STAS 10107 3-1977 Non industrial industrial and agricultural buildings REINFORCED AND PRESTRESSED CONCRETE RIBBED FLOORS Design requirements《非工业,工业和农业的建筑物 加强和预应力混凝土加肋楼板 设计要求 》.pdf STAS 10107 3-1977 Non industrial industrial and agricultural buildings REINFORCED AND PRESTRESSED CONCRETE RIBBED FLOORS Design requirements《非工业,工业和农业的建筑物 加强和预应力混凝土加肋楼板 设计要求 》.pdf
  • STAS 10107 4-1990 Non-industrial industrial and agricultural buildings Reinforced concrete coffered ceilings Design specifications《非工业,工业和农业建筑 钢筋混凝土方格天花板 设计规范 》.pdf STAS 10107 4-1990 Non-industrial industrial and agricultural buildings Reinforced concrete coffered ceilings Design specifications《非工业,工业和农业建筑 钢筋混凝土方格天花板 设计规范 》.pdf
  • STAS 10108 0-1978 Non industrial industrial and agriculture buildings DESIGN OF STEEL MEMBERS《非工业,工业和农业建筑物 钢构件的设计 》.pdf STAS 10108 0-1978 Non industrial industrial and agriculture buildings DESIGN OF STEEL MEMBERS《非工业,工业和农业建筑物 钢构件的设计 》.pdf
  • STAS 10108 1-1981 Industrial non-industrial and agriculture buildings DESIGN RULES FOR STEEL TUBES BUILDINGS《工业,非工业和农业建筑 钢管建筑物的设计规则 》.pdf STAS 10108 1-1981 Industrial non-industrial and agriculture buildings DESIGN RULES FOR STEEL TUBES BUILDINGS《工业,非工业和农业建筑 钢管建筑物的设计规则 》.pdf
  • STAS 10108 2-1983 Steel structures DESIGN OF STEEL STRUCTURES OF THIN WALLED GOLD FORMED SECTIONS《钢结构 薄壁金制截面的钢结构的设计 》.pdf STAS 10108 2-1983 Steel structures DESIGN OF STEEL STRUCTURES OF THIN WALLED GOLD FORMED SECTIONS《钢结构 薄壁金制截面的钢结构的设计 》.pdf
  • STAS 10109 0-1975 Non-industrial industrial and farm constructions MASONRY WORKS Erection and constructional data《非工业,工业及农业建筑 砌体工程 装配和施工数据 》.pdf STAS 10109 0-1975 Non-industrial industrial and farm constructions MASONRY WORKS Erection and constructional data《非工业,工业及农业建筑 砌体工程 装配和施工数据 》.pdf
  • STAS 10109 1-1982 Non-industrial industrial and farm constructions MASONRY WORKS Design and errection elements《非工业,工业和农业结构 砌体工程 设计和装配零件 》.pdf STAS 10109 1-1982 Non-industrial industrial and farm constructions MASONRY WORKS Design and errection elements《非工业,工业和农业结构 砌体工程 设计和装配零件 》.pdf
  • STAS 10110-1985 Water supplies INJECTION STATION General rules for designing《供水 注水站 设计的一般规则 》.pdf STAS 10110-1985 Water supplies INJECTION STATION General rules for designing《供水 注水站 设计的一般规则 》.pdf
  • STAS 10111 1-1977 Road and railway bridges MASONRY CONCRETE AND REINFORCED CONCRETE SURSTRUCTURES Designing rules《公路和铁路桥梁,砖石,混凝土及钢筋混凝土表面结构 设计规则 》.pdf STAS 10111 1-1977 Road and railway bridges MASONRY CONCRETE AND REINFORCED CONCRETE SURSTRUCTURES Designing rules《公路和铁路桥梁,砖石,混凝土及钢筋混凝土表面结构 设计规则 》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1