FORD WB 900 APPENDIX F-2013 Enhanced hexalobular internal driving feature for bolts and screws.pdf

上传人:bowdiet140 文档编号:748451 上传时间:2019-01-14 格式:PDF 页数:7 大小:410.66KB
下载 相关 举报
FORD WB 900 APPENDIX F-2013 Enhanced hexalobular internal driving feature for bolts and screws.pdf_第1页
第1页 / 共7页
FORD WB 900 APPENDIX F-2013 Enhanced hexalobular internal driving feature for bolts and screws.pdf_第2页
第2页 / 共7页
FORD WB 900 APPENDIX F-2013 Enhanced hexalobular internal driving feature for bolts and screws.pdf_第3页
第3页 / 共7页
FORD WB 900 APPENDIX F-2013 Enhanced hexalobular internal driving feature for bolts and screws.pdf_第4页
第4页 / 共7页
FORD WB 900 APPENDIX F-2013 Enhanced hexalobular internal driving feature for bolts and screws.pdf_第5页
第5页 / 共7页
点击查看更多>>
资源描述

1、 WORLDWIDE FASTENER STANDARD WB 900 Appendix F 2013-12-20 Printed copies are uncontrolled Copyright 2012, Ford Global Technologies, LLC Page 1 of 7 Enhanced hexalobular internal driving feature for bolts and screws 1 Scope This Ford Motor Company standard specifies the shape and basic dimensions of

2、enhanced hexalobular internal driving feature for bolts and screws including the gauging method. The curvature of the contour of the enhanced hexalobular internal driving feature is defined by the gauges specified in Tables 3, 4 and 5. Additional information which may be used when drawing the contou

3、r is given in the informative annex A. 2 Basic dimensions See Figure 1 and Table 1 Figure 1 Basic Dimensions Counterbore c: 0.13 mm maximum for socket No. 6 IP through 15 IP, 0.25 mm maximum over socket No. 15 IP Penetration depth I: See relevant product standard. NOTE: The contour of the bottom of

4、the socket beyond the gauge is at the option of the manufacturer. WORLDWIDE FASTENER STANDARD WB 900 Appendix F 2013-12-20 Printed copies are uncontrolled Copyright 2012, Ford Global Technologies, LLC Page 2 of 7 Table 1 Basic Dimensions Dimensions in millimeters Hexalobular Socket No. Nominal Dimen

5、sions A (ref) B (ref) 6 IP 1.75 1.27 8 IP 2.39 1.75 10 IP 2.82 2.05 15 IP 3.35 2.4 20 IP 3.94 2.85 25 IP 4.52 3.25 30 IP 5.61 4.05 40 IP 6.76 4.85 45 IP 7.92 5.64 50 IP 8.94 6.45 55 IP 11.33 8.05 60 IP 13.44 9.6 Table 2 Enhanced Hexalobular Internal Drive Tolerances Dimensions in millimeters Socket

6、No. A B Ea Eb Fa Fb Drive Size Max Min Max Min Ref Ref Ref Ref 6 IP 1.7842 1.7416 1.3877 1.3454 0.1245 0.2313 0.0775 0.1843 8 IP 2.4241 2.3818 1.8653 1.823 0.1651 0.3051 0.1181 0.2581 10 IP 2.8508 2.8008 2.1802 2.1302 0.1969 0.359 0.145 0.3082 15 IP 3.3842 3.3342 2.612 2.562 0.2222 0.4233 0.1714 0.3

7、725 20 IP 3.9684 3.9184 3.0946 3.0446 0.2476 0.4945 0.1968 0.4437 25 IP 4.5649 4.4899 3.4981 3.4231 0.3023 0.565 0.2388 0.5015 30 IP 5.6571 5.5821 4.3973 4.3223 0.3505 0.6979 0.287 0.6344 40 IP 6.8134 6.7124 5.2894 5.1884 0.4229 0.8385 0.3467 0.7623 45 IP 7.9818 7.8808 6.2952 6.1942 0.4635 0.9839 0.

8、3874 0.9077 50 IP 8.9978 8.8968 6.9861 6.8851 0.5448 1.0964 0.4686 1.0202 55 IP 11.3854 11.2844 9.0842 8.9832 0.6236 1.4048 0.5347 1.3159 60 IP 13.4424 13.3418 10.5214 10.4208 0.7912 1.6518 0.6769 1.5375 Note: Min A & B dimensions are the max tool dimension +0.05mm to accommodate for max coating thi

9、ckness Max A & B dimensions are the Min A & B dimensions + the standard hexalobular drive tolerance E & F are reference values using max go-gage radius WORLDWIDE FASTENER STANDARD WB 900 Appendix F 2013-12-20 Printed copies are uncontrolled Copyright 2012, Ford Global Technologies, LLC Page 3 of 7 3

10、 Gauging 3.1 Principle The enhanced hexalobular internal driving feature shall allow the GO gauge to enter freely to the penetration depth I as specified in the relevant product standards. The NO GO gauges shall not enter the enhanced hexalobular internal driving feature to a depth greater than the

11、fallaway allowance specified in Table 3. If the gage penetrates the internal drive feature outside of the specified fallaway allowance the part will be deemed unacceptable. Table 3 Fallaway Allowance Dimensions in millimeters Socket No. 6 IP 8 IP 10 IP 15 IP 20 IP 25 IP 30 IP 40 IP 45 IP 50 IP 55 IP

12、 60 IP Fallaway Allowance f 0.35 0.48 0.56 0.67 0.79 0.90 1.12 1.18 1.39 1.56 1.98 2.35 All gauging is performed with reference to the top surface of the head. In the case of oval or round top heads, measurements are taken from the actual intersection of the top surface of the head and the hexalobul

13、ar internal driving feature counter bore. When using a dial penetration gauge, this should be adjusted to zero while the gauge is pressed against a flat surface thereby compressing the plunger to make it flush with the gauge reference surface. See Figure 2. Figure 2 Penetration gauge in zero positio

14、n WORLDWIDE FASTENER STANDARD WB 900 Appendix F 2013-12-20 Printed copies are uncontrolled Copyright 2012, Ford Global Technologies, LLC Page 4 of 7 3.2 GO gauge The GO gauge shall have dimensions within the limits specified in Table 4. Figure 3 Dimensions of the GO gauge Table 4 Limiting sizes of d

15、imensions of the GO gauge Dimensions in millimeters Socket A B Ea Eb Fa Fb H Num. Min Max Min Max Min Max Min Max Min Max Min Max 0.25 6 IP 1.7018 1.7094 1.3056 1.3132 0.1207 0.1245 0.2275 0.2313 0.0737 0.0775 0.1805 0.1843 2.79 8 IP 2.3419 2.3495 1.7831 1.7907 0.1613 0.1651 0.3013 0.3051 0.1143 0.1

16、181 0.2543 0.2581 2.79 10 IP 2.7610 2.7762 2.0904 2.1057 0.1892 0.1969 0.3514 0.3590 0.1384 0.1460 0.3006 0.3082 2.79 15 IP 3.2944 3.3096 2.5222 2.5375 0.2146 0.2222 0.4157 0.4233 0.1638 0.1714 0.3649 0.3725 2.79 20 IP 3.8786 3.8938 3.0048 3.0201 0.2400 0.2476 0.4868 0.4945 0.1892 0.1968 0.4360 0.44

17、37 3.81 25 IP 4.4501 4.4653 3.3833 3.3985 0.2946 0.3023 0.5574 0.5650 0.2311 0.2388 0.4939 0.5015 4.19 30 IP 5.5423 5.5575 4.2824 4.2977 0.3429 0.3505 0.6902 0.6979 0.2794 0.2870 0.6267 0.6344 4.70 40 IP 6.6726 6.6878 5.1486 5.1638 0.4153 0.4229 0.8309 0.8385 0.3391 0.3467 0.7547 0.7623 5.33 45 IP 7

18、8410 7.8562 6.1544 6.1697 0.4559 0.4635 0.9763 0.9839 0.3797 0.3874 0.9001 0.9077 5.97 50 IP 8.8570 8.8722 6.8453 6.8605 0.5372 0.5448 1.0888 1.0964 0.4610 0.4686 1.0126 1.0202 6.22 55 IP 11.2446 11.2598 8.9433 8.9586 0.6159 0.6236 1.3972 1.4048 0.5271 0.5347 1.3083 1.3159 6.48 60 IP 13.3020 13.317

19、2 10.3810 10.3962 0.7836 0.7912 1.6441 1.6518 0.6693 0.6769 1.5298 1.5375 7.92 WORLDWIDE FASTENER STANDARD WB 900 Appendix F 2013-12-20 Printed copies are uncontrolled Copyright 2012, Ford Global Technologies, LLC Page 5 of 7 3.3 NOT GO gauges 3.3.1 Gauging the fallaway dimensions The fallaway gauge

20、 dimension limits are specified in Table 5. Figure 4 Dimensions of the fallaway gauge Table 5 Limiting sizes of dimensions of the fallaway gauge Dimensions in millimeters Socket Num. A K Fa Fb H V R -0.0000 +0.0076 Max -0.0000 +0.0038 -0.0000 +0.0038 0.25 +0.0000 -0.0038 Rad. 6 IP 1.7856 1.1834 0.11

21、56 0.2224 2.79 0.1894 0.03 8 IP 2.4257 1.5945 0.1562 0.2962 2.79 0.2632 0.03 10 IP 2.8524 1.8652 0.1841 0.3463 2.79 0.3133 0.05 15 IP 3.3858 2.2192 0.2095 0.4106 2.79 0.3776 0.05 20 IP 3.9700 2.6102 0.2349 0.4818 2.79 0.4487 0.05 25 IP 4.5669 2.9822 0.2896 0.5523 2.79 0.5066 0.05 30 IP 5.6591 3.7122

22、 0.3378 0.6852 4.70 0.6394 0.05 40 IP 6.8148 4.4673 0.4102 0.8258 5.33 0.7674 0.05 45 IP 7.9832 5.2636 0.4509 0.9712 5.97 0.9128 0.05 50 IP 8.9992 5.8920 0.5321 1.0837 6.22 1.0253 0.05 55 IP 11.4122 7.5562 0.6109 1.3921 6.48 1.3210 0.05 60 IP 13.495 8.8605 0.7658 1.6264 7.92 1.5552 0.05 WORLDWIDE FA

23、STENER STANDARD WB 900 Appendix F 2013-12-20 Printed copies are uncontrolled Copyright 2012, Ford Global Technologies, LLC Page 6 of 7 Table 6 Socket Gauging Penetration Tolerances Dimensions in millimeters I=Recess Gauge Penetration Head Type Pan 90 Raised Countersunk 90 Flat Countersunk A B C Rece

24、ss Ref. Suitable screw sizes for head forms and recess specified Head form dimensions as specified in: WB900 or WD900 Head form dimensions as specified in: WB900 or WD900 Head form dimensions as specified in: WB900 or WD900 Dimension (I) Dimension (I) Dimension (I) Max. Min. Max. Min. Max. Min. 6 IP

25、 M2 0.81 0.68 0.72 0.6 0.72 0.6 10 IP M3 1.3 1.1 1.16 0.96 1.16 0.96 15 IP ST3.5 1.54 1.31 1.37 1.14 1.37 1.14 20 IP M4, ST4.2 1.81 1.54 1.62 1.34 1.62 1.34 25 IP M5, ST4.8 2.08 1.76 1.85 1.54 1.85 1.54 30 IP M6,ST6.3 2.58 2.19 2.3 1.91 2.3 1.91 40 IP M8 3.11 2.64 2.76 2.28 2.77 2.3 50 IP M10 4.11 3

26、49 3.67 3.04 3.67 3.04 55 IP M12 5.21 4.58 NA NA NA NA WORLDWIDE FASTENER STANDARD WB 900 Appendix F 2013-12-20 Printed copies are uncontrolled Copyright 2012, Ford Global Technologies, LLC Page 7 of 7 Annex A (Informative) Representation of enhanced hexalobular internal driving feature contour NOTE: The correlations of dimensions given in Figure A.1 are intended to support the drawing of the driving feature only, e.g. when using a CAD system. Scale to socket nominal dimension per Table 1 as needed. Figure A.1 Representation of enhanced hexalobular internal driving feature

展开阅读全文
相关资源
猜你喜欢
  • DIN 25424-2-1990 Fault tree analysis manual calculation procedures for the evaluation of a fault tree《故障树分析 评价故障树的手算方法》.pdf DIN 25424-2-1990 Fault tree analysis manual calculation procedures for the evaluation of a fault tree《故障树分析 评价故障树的手算方法》.pdf
  • DIN 25425-1 Bb 1-2016 Radioisotope laboratories - Part 1 Rules for design Supplement 1 Examples for application《放射性同位元素实验室 第1部分 设计规则 补充件1 应用实例》.pdf DIN 25425-1 Bb 1-2016 Radioisotope laboratories - Part 1 Rules for design Supplement 1 Examples for application《放射性同位元素实验室 第1部分 设计规则 补充件1 应用实例》.pdf
  • DIN 25425-1-2016 Radioisotope laboratories - Part 1 Rules for design《放射性同位素实验室 第1部分 设计规则》.pdf DIN 25425-1-2016 Radioisotope laboratories - Part 1 Rules for design《放射性同位素实验室 第1部分 设计规则》.pdf
  • DIN 25425-3-2012 Radionuclide laboratories - Part 3 Rules for preventive fire protection《放射性核素实验室 第3部分 防火保护规则》.pdf DIN 25425-3-2012 Radionuclide laboratories - Part 3 Rules for preventive fire protection《放射性核素实验室 第3部分 防火保护规则》.pdf
  • DIN 25425-4 Bb 1-2013 Radioisotope laboratories - Part 4 Rules for the protection of persons Supplement 1 Guidance notes on preparing a radiation protection directive for handling .pdf DIN 25425-4 Bb 1-2013 Radioisotope laboratories - Part 4 Rules for the protection of persons Supplement 1 Guidance notes on preparing a radiation protection directive for handling .pdf
  • DIN 25425-4 Bb 2-2013 Radioisotope laboratories Part 4 Rules for the protection of persons Guidance notes on shielding of gamma- and beta-radiation《放射性同位素实验室 第4部分 人员保护规则 伽马和贝它射线辐射防.pdf DIN 25425-4 Bb 2-2013 Radioisotope laboratories Part 4 Rules for the protection of persons Guidance notes on shielding of gamma- and beta-radiation《放射性同位素实验室 第4部分 人员保护规则 伽马和贝它射线辐射防.pdf
  • DIN 25425-4-2012 Radioisotope laboratories - Part 4 Rules for the protection of persons《放射性同位素实验室 第4部分 人员保护规则》.pdf DIN 25425-4-2012 Radioisotope laboratories - Part 4 Rules for the protection of persons《放射性同位素实验室 第4部分 人员保护规则》.pdf
  • DIN 25425-5-2011 Radioisotope laboratories - Part 5 Rules for the decontamination of surfaces《放射性同位素实验室 第5部分 表面去污规则》.pdf DIN 25425-5-2011 Radioisotope laboratories - Part 5 Rules for the decontamination of surfaces《放射性同位素实验室 第5部分 表面去污规则》.pdf
  • DIN 25426-3-1991 Sealed radioactive sources leakage test methods as part of production and prototype testing《密封放射性材料 第3部分 当作生产和原型试验一部分的渗漏试验方法》.pdf DIN 25426-3-1991 Sealed radioactive sources leakage test methods as part of production and prototype testing《密封放射性材料 第3部分 当作生产和原型试验一部分的渗漏试验方法》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1