FORD WSK-M3G200-A-2006 TAPE ADHESIVE PRESSURE SENSITIVE TWO SIDED INTERIOR TO BE USED WITH FORD WSS-M99P1111-A 《汽车内部用双面压敏胶带 与标准FORD WSS-M99P1111-A一起使用 》.pdf

上传人:rimleave225 文档编号:750571 上传时间:2019-01-14 格式:PDF 页数:3 大小:74.01KB
下载 相关 举报
FORD WSK-M3G200-A-2006 TAPE ADHESIVE PRESSURE SENSITIVE TWO SIDED INTERIOR  TO BE USED WITH FORD WSS-M99P1111-A  《汽车内部用双面压敏胶带  与标准FORD WSS-M99P1111-A一起使用 》.pdf_第1页
第1页 / 共3页
FORD WSK-M3G200-A-2006 TAPE ADHESIVE PRESSURE SENSITIVE TWO SIDED INTERIOR  TO BE USED WITH FORD WSS-M99P1111-A  《汽车内部用双面压敏胶带  与标准FORD WSS-M99P1111-A一起使用 》.pdf_第2页
第2页 / 共3页
FORD WSK-M3G200-A-2006 TAPE ADHESIVE PRESSURE SENSITIVE TWO SIDED INTERIOR  TO BE USED WITH FORD WSS-M99P1111-A  《汽车内部用双面压敏胶带  与标准FORD WSS-M99P1111-A一起使用 》.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 ENGINEERING MATERIAL SPECIFICATIONDate Action Revisions 2006 01 27 Revised Inserted 3.0; Deleted 3.1, 3.2, 3.3, 3.10, 4 1992 07 01 Released EPOOE10176272000 C. Dittebrandt Printed copies are uncontrolled Copyright 2006, Ford Global Technologies, LLC Page 1 of 3 TAPE, ADHESIVE, PRESSURE SENSITIVE, T

2、WO SIDED, INTERIOR WSK-M3G200-A 1. SCOPE The material defined by this specification is a double sided adhesive tape with a PVC or PP carrier. One side is protected by a release liner. 2. APPLICATION This specification was released originally for materials used for fixing headlining to enameled panel

3、 Prior to the release for a particular application and in addition to the requirements specified within this specification, full evaluation as a component of specific trim products must be tested by the responsible Component Engineering activity on substrates intended for use in the final applicati

4、on. 3. REQUIREMENTS 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.4 MATERIAL PROPERTIES 3.4.1 Color White 3.4.2 Thickness 0.18 - 0.30 mm (ASTM D 1000) 3.4.3 Widt

5、h See 5.3 3.4.4 Breaking Strength, min 3800 N/m (ASTM D 1000) 3.4.5 Elongation 20 - 55% (ASTM D 1000) 3.5 PREPARATION OF TEST SPECIMENS Steel panels, painted with current production enamel according to respective paint specification if not otherwise specified. Test specimens shall be wiped with isop

6、ropanol/water (1:1) and dry wiped with a lint free tissue soaked with n- heptane prior to applying the tape or as recommended by supplier. Usage of a primer shall be noted in the Initial Sample Report. ENGINEERING MATERIAL SPECIFICATIONWSK-M3G200-APrinted copies are uncontrolled Copyright 2006, Ford

7、 Global Technologies, LLC Page 2 of 3 3.6 AGING CONDITIONS Expose Test Specimens to each of the following conditions before testing per para 3.6. 3.6.1 1 h at 23 +/- 2 C 3.6.2 Humidity aging 14 d at 38 +/- 2 C, 98 +/- 2% RH Reconditioning: 4 h at 23 C and 50 +/- 5% RH 3.6.3 Heat aging 14 d at 80 +/-

8、 2 C; Reconditioning: 4 h at 23 C and 50 +/- 5% RH 3.6.4 Paint Repair Oven 30 minutes at 120 +/- 2 C; Reconditioning: 4 h at 23 C and 50 +/- 5% RH 3.6.5 Environmental Cycling (FLTM BQ 104-07, Procedure 5) Reconditioning: 4 h at 23 C and 50 +/- 5% RH 3.7 ADHESION PROPERTIES 3.7.1 Peel Adhesion (ASTM

9、D 1000 Method A, clause 40 - 42) Prior to testing cover unlined side of the tape with a polyester film of approx. 0.04 mm thickness to avoid elongation during testing. Aged per 3.6.1, min 800 N/m Aged per 3.6.2, min 800 N/m Aged per 3.6.3, min 800 N/m Aged per 3.6.4, min 800 N/m Aged per 3.6.5, min

10、800 N/m 3.7.2 Shear Adhesion, min 0.8 N/mm2(FLTM BU 151-01, Method A, Fig. 2) Prior to testing cover unlined side of the tape with a polyester film of 0.1 mm thickness to avoid elongation during testing. 1 h after bonding 3.7.3 Softening Point, min 80 C (ASTM D 816) Prepare test specimen according 3

11、5. Maintain oven temperature at 35 C for 15 minutes, then increase in steps of 2.5 C/ 5 minutes until bond failure. ENGINEERING MATERIAL SPECIFICATIONWSK-M3G200-APrinted copies are uncontrolled Copyright 2006, Ford Global Technologies, LLC Page 3 of 3 3.7.4 Liner Removal, max 20 N/m (ASTM D 1000, M

12、ethod A) 3.8 FOGGING, min (FLTM BO 116-03) Fog Number, min 60 Perform the test with the tape between aluminum foils or steel panels. 3.9 FLAMMABILITY, max (ISO 3795/SAE J369) Burn Rate, max 100 mm/minute Perform the test with the tape between aluminum foils or steel panels. 5. GENERAL INFORMATION Th

13、e information given below is provided for clarification and assistance in meeting the requirements of this specification. 5.1 STORAGE STABILITY 6 months (From date of receipt at FMC) 5.2 STORAGE TEMPERATURE 10 C to 28 C 5.3 WIDTH OF TAPE - SECOND SUFFIX The width of tape shall be identified by an additional suffix to the specification number as follows: Suffix for width 09 9 mm 12 12 mm 15 15 mm 19 19 mm 25 25 mm 30 30 mm 38 38 mm 50 50 mm

展开阅读全文
相关资源
猜你喜欢
  • ASHRAE LO-09-025-2009 Specific Energy Consumption (SEC) for the Integrated Circuit Assembly and Testing (IC A T) Industry in Taiwan《台湾集成电路组件和测试(IC A T)工业用能量消耗率》.pdf ASHRAE LO-09-025-2009 Specific Energy Consumption (SEC) for the Integrated Circuit Assembly and Testing (IC A T) Industry in Taiwan《台湾集成电路组件和测试(IC A T)工业用能量消耗率》.pdf
  • ASHRAE LO-09-026-2009 Humidification of Large-Scale Cleanrooms by Adiabatic Humidification Method in Subtropical Areas An Industrial Case Study《通过绝热增湿法测定亚热带地区大尺度洁净室内的湿润性》.pdf ASHRAE LO-09-026-2009 Humidification of Large-Scale Cleanrooms by Adiabatic Humidification Method in Subtropical Areas An Industrial Case Study《通过绝热增湿法测定亚热带地区大尺度洁净室内的湿润性》.pdf
  • ASHRAE LO-09-027-2009 Required Duration For Borehole Test Validated by Field Data《通过现场数据对确定钻孔测试所需时间》.pdf ASHRAE LO-09-027-2009 Required Duration For Borehole Test Validated by Field Data《通过现场数据对确定钻孔测试所需时间》.pdf
  • ASHRAE LO-09-028-2009 Comparison of Airflow and Contaminant Distributions in Rooms with Traditional Displacement Ventilation and Under-Floor Air Distribution Systems《传统置换通风房间和地下气体分.pdf ASHRAE LO-09-028-2009 Comparison of Airflow and Contaminant Distributions in Rooms with Traditional Displacement Ventilation and Under-Floor Air Distribution Systems《传统置换通风房间和地下气体分.pdf
  • ASHRAE LO-09-029-2009 Air Distribution Effectiveness with Stratified Air Distribution Systems《分层气流组织系统中气流组织效能的研究》.pdf ASHRAE LO-09-029-2009 Air Distribution Effectiveness with Stratified Air Distribution Systems《分层气流组织系统中气流组织效能的研究》.pdf
  • ASHRAE LO-09-030-2009 In-Situ Performance of Stratified Air Distribution Systems in Two Canadian Buildings《两个加拿大建筑中分层空气分配系统的原地性能》.pdf ASHRAE LO-09-030-2009 In-Situ Performance of Stratified Air Distribution Systems in Two Canadian Buildings《两个加拿大建筑中分层空气分配系统的原地性能》.pdf
  • ASHRAE LO-09-031-2009 Discussion of Design Method and Optimization on Airflow Distribution in a Large-Space Building with Stratified Air-Conditioning System《关于带有分层空调系统的大型建筑中气流分布的设计.pdf ASHRAE LO-09-031-2009 Discussion of Design Method and Optimization on Airflow Distribution in a Large-Space Building with Stratified Air-Conditioning System《关于带有分层空调系统的大型建筑中气流分布的设计.pdf
  • ASHRAE LO-09-032-2009 Contaminant Transport and Filtration Issues with DOAS《用DOAS垃圾运输和过滤处理问题》.pdf ASHRAE LO-09-032-2009 Contaminant Transport and Filtration Issues with DOAS《用DOAS垃圾运输和过滤处理问题》.pdf
  • ASHRAE LO-09-033-2009 Role of Safety Factors in the Design of Dedicated Outdoor-Air Systems《专用室外空气系统设计安全系数的作用》.pdf ASHRAE LO-09-033-2009 Role of Safety Factors in the Design of Dedicated Outdoor-Air Systems《专用室外空气系统设计安全系数的作用》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1