FORD WSS-M1H1205-A-2009 FABRIC NAZCA PATTERN WOVEN JACQUARD TO BE USED WITH FORD WSS-M99P1111-A 《NAZCA图案的提花机织织物 与标准FORD WSS-M99P1111-A一起使用 》.pdf

上传人:outsidejudge265 文档编号:751943 上传时间:2019-01-14 格式:PDF 页数:2 大小:25.39KB
下载 相关 举报
FORD WSS-M1H1205-A-2009 FABRIC NAZCA PATTERN WOVEN JACQUARD  TO BE USED WITH FORD WSS-M99P1111-A  《NAZCA图案的提花机织织物  与标准FORD WSS-M99P1111-A一起使用 》.pdf_第1页
第1页 / 共2页
FORD WSS-M1H1205-A-2009 FABRIC NAZCA PATTERN WOVEN JACQUARD  TO BE USED WITH FORD WSS-M99P1111-A  《NAZCA图案的提花机织织物  与标准FORD WSS-M99P1111-A一起使用 》.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 ENGINEERING MATERIAL SPECIFICATIONDate Action Revisions 2009 05 28 Activated V. Demarchi, FSAO Printed copies are uncontrolled Copyright 2009, Ford Global Technologies, LLC Page 1 of 2 FABRIC, NAZCA PATTERN, WOVEN JACQUARD WSS-M1H1205-A 1. SCOPE The material defined by this specification is a woven

2、 jacquard polyester face fabric. 2. APPLICATION This specification was released originally for material used as an interior trim fabric for 2011 BV256 Seat and Door Panel. 3. REQUIREMENTS In addition, to the requirements listed herein, the fabric shall meet all requirements of WSS-M8P18-A1/A4 as app

3、licable. 3.1 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements for Production Materials (WSS-M99P1111-A). 3.2 FABRIC CONSTRUCTION 3.2.1 Fabric Count, +/- 5% tolerance (ASTM D 3887) Warp 45.0 yarn/cm Fill 38.0 yarn/

4、cm 3.2.2 Fabric Weight, +/- 10%, g/m 315 (face fabric) (FLTM BN 106-01) Face w/no Back coat 283 347 Laminated* 393 507 * 2 mm foam thickness + backing fabric 3.3 COMPOSITION (ASTM D 629) Tolerance as specified in WSS-M8P18-A1/A4 Fabric 100% Polyester Backing Fabric (Seats only) 100% Polyester ENGINE

5、ERING MATERIAL SPECIFICATIONWSS-M1H1205-A Printed copies are uncontrolled Copyright 2009, Ford Global Technologies, LLC Page 2 of 2 3.4 YARN CONSTRUCTION (ASTM D 1244) War 2 x 167 dtex, f 34, Semi dull, Round, False Twist Textured, Polyester Fill 250 dtex, f 72 Semi dull, Round, False Twist Textured

6、 Polyester Fill 250 dtex, f 68 Semi dull, Round, False Twist Textured, Polyester 3.5 METHOD OF DYEING Piece Dyed 3.6 FINISHING OPERATIONS Dye, Heat-Setting, Lamination 4. GENERAL INFORMATION The information given below is provided for clarification and assistance in meeting the requirements of this specification. 4.1 Purchase departments will ensure that both materials defined in this specification and shipped to any one assembly plant will be produced by one supplier only

展开阅读全文
相关资源
猜你喜欢
  • ETSI EN 302 195-1-2004 Electromagnetic compatibility and Radio spectrum Matters (ERM) Radio equipment in the frequency range 9 kHz to 315 kHz for Ultra Low Power Active Medical Imp_1.pdf ETSI EN 302 195-1-2004 Electromagnetic compatibility and Radio spectrum Matters (ERM) Radio equipment in the frequency range 9 kHz to 315 kHz for Ultra Low Power Active Medical Imp_1.pdf
  • ETSI EN 302 195-2-2004 Electromagnetic compatibility and Radio spectrum Matters (ERM) Radio equipment in the frequency range 9 kHz to 315 kHz for Ultra Low Power Active Medical Imp.pdf ETSI EN 302 195-2-2004 Electromagnetic compatibility and Radio spectrum Matters (ERM) Radio equipment in the frequency range 9 kHz to 315 kHz for Ultra Low Power Active Medical Imp.pdf
  • ETSI EN 302 195-2-2004 Electromagnetic compatibility and Radio spectrum Matters (ERM) Radio equipment in the frequency range 9 kHz to 315 kHz for Ultra Low Power Active Medical Imp_1.pdf ETSI EN 302 195-2-2004 Electromagnetic compatibility and Radio spectrum Matters (ERM) Radio equipment in the frequency range 9 kHz to 315 kHz for Ultra Low Power Active Medical Imp_1.pdf
  • ETSI EN 302 195-2016 Short Range Devices (SRD) Ultra Low Power Active Medical Implants (ULP-AMI) and accessories (ULP-AMI-P) operating in the frequency range 9 kHz to 315 kHz Harmo.pdf ETSI EN 302 195-2016 Short Range Devices (SRD) Ultra Low Power Active Medical Implants (ULP-AMI) and accessories (ULP-AMI-P) operating in the frequency range 9 kHz to 315 kHz Harmo.pdf
  • ETSI EN 302 195-2016 Short Range Devices (SRD) Ultra Low Power Active Medical Implants (ULP-AMI) and accessories (ULP-AMI-P) operating in the frequency range 9 kHz to 315 kHz Harmo_1.pdf ETSI EN 302 195-2016 Short Range Devices (SRD) Ultra Low Power Active Medical Implants (ULP-AMI) and accessories (ULP-AMI-P) operating in the frequency range 9 kHz to 315 kHz Harmo_1.pdf
  • ETSI EN 302 208-1-2015 Electromagnetic compatibility and Radio spectrum Matters (ERM) Radio Frequency Identification Equipment operating in the band 865 MHz to 868 MHz with power l.pdf ETSI EN 302 208-1-2015 Electromagnetic compatibility and Radio spectrum Matters (ERM) Radio Frequency Identification Equipment operating in the band 865 MHz to 868 MHz with power l.pdf
  • ETSI EN 302 208-1-2015 Electromagnetic compatibility and Radio spectrum Matters (ERM) Radio Frequency Identification Equipment operating in the band 865 MHz to 868 MHz with power l_1.pdf ETSI EN 302 208-1-2015 Electromagnetic compatibility and Radio spectrum Matters (ERM) Radio Frequency Identification Equipment operating in the band 865 MHz to 868 MHz with power l_1.pdf
  • ETSI EN 302 208-2-2015 Electromagnetic compatibility and Radio spectrum Matters (ERM) Radio Frequency Identification Equipment operating in the band 865 MHz to 868 MHz with power l.pdf ETSI EN 302 208-2-2015 Electromagnetic compatibility and Radio spectrum Matters (ERM) Radio Frequency Identification Equipment operating in the band 865 MHz to 868 MHz with power l.pdf
  • ETSI EN 302 208-2-2015 Electromagnetic compatibility and Radio spectrum Matters (ERM) Radio Frequency Identification Equipment operating in the band 865 MHz to 868 MHz with power l_1.pdf ETSI EN 302 208-2-2015 Electromagnetic compatibility and Radio spectrum Matters (ERM) Radio Frequency Identification Equipment operating in the band 865 MHz to 868 MHz with power l_1.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1