FORD WSS-M1H1229-A2-2016 FABRIC OMNI WOVEN UNLAMINATED TO BE USED WITH FORD WSS-M99P1111-A (Shown on FORD WRS-M1H1229-A).pdf

上传人:arrownail386 文档编号:751966 上传时间:2019-01-14 格式:PDF 页数:2 大小:47.11KB
下载 相关 举报
FORD WSS-M1H1229-A2-2016 FABRIC OMNI WOVEN UNLAMINATED  TO BE USED WITH FORD WSS-M99P1111-A  (Shown on FORD WRS-M1H1229-A).pdf_第1页
第1页 / 共2页
FORD WSS-M1H1229-A2-2016 FABRIC OMNI WOVEN UNLAMINATED  TO BE USED WITH FORD WSS-M99P1111-A  (Shown on FORD WRS-M1H1229-A).pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 ENGINEERING MATERIAL SPECIFICATION Date Action Revisions Rev. 3 2016 05 19 N Status A/A2 No future usage D. Murtonen, NA 2015 06 09 Released A20 No Back Coat Version D. Murtonen, FNA 2012 03 28 Activated M.Dumitrescu, NA Controlled document at www.MATS Copyright 2016, Ford Global Technologies, LLC

2、Page 1 of 2 FABRIC, OMNI, WOVEN, WRS-M1H1229-A 43% PIR/PCR UNLAMINATED NOT TO BE USED FOR NEW DESIGN FABRIC, OMNI, WOVEN, WSS-M1H1229-A2 UNLAMINATED NOT TO BE USED FOR NEW DESIGN FABRIC, OMNI, WOVEN, 43% MINIMUM PIR/PCR, NO BACK COAT WRS-M1H1229-A20 UNLAMINATED 1. SCOPE The material defined is a wov

3、en polyester face fabric. Material conforming to WRS-M1H1229-A and A20 contains 43% PIR/PCR (Post industrial/post consumer) recycled yarn. 2. APPLICATION This specification was released originally for material used as an interior trim fabric for 2013 Fusion seat insert and/or bolster for EU and Chin

4、a production. The fabric was originally approved as trilaminated with foam and backing fabric/scrim. 3. REQUIREMENTS 3.1 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A).

5、Materials with recycled content as defined by WRS-M99P42-A2 (Textile Materials, Identification of Recycled Content) should be used whenever technically feasible. 3.1.1 WRS-M1H1229-A. This specification must contain 43% minimum recycled content as defined by WRS-M99P42-A2/latest. The remaining portio

6、n of the material can come from virgin sources. 3.1.2 WRS-M1H1229-A20. This specification must contain 43% minimum recycled content as defined by WRS-M99P42-A2/latest. The remaining portion of the material can come from virgin sources. 3.1.3 WSS-M1H1229-A2. This specification is based on virgin mate

7、rials. 3.1.4 In addition to the requirements listed herein, the fabric shall meet all requirements of WSS-M8P18-A1/A2/A3/A4 as applicable. 3.2 FABRIC CONSTRUCTION 3.2.1 Fabric Count, -10 /+ 10 % tolerance (ASTM D3775) Warp 905 / 10 cm Weft 283/ 10 cm ENGINEERING MATERIAL SPECIFICATION WRS-M1H1229-A/

8、A20 WSS-M1H1229-A2 Copyright 2016, Ford Global Technologies, LLC Page 2 of 2 3.2.2 Fabric Weight, -10 + 10 % tolerance (FLTM BN 106-01) WRS-M1H1229-A and WSS-M1H1229-A2 Face fabric 320 g/m2 Backcoat 55g/m2 Total Weight 375 g/m2 WRS-M1H1229-A20 Face fabric 320 g/m2 3.3 COMPOSITION (ASTM D629) WRS-M1H

9、1229-A and WSS-M1H1229-A2 Fabric 100% polyester Backcoating Acrylic Backing fabric/scrim 100% polyester, Circular knit WRS-M1H1229-A20 Fabric 100% polyester Backing fabric/scrim 100% polyester, Circular knit 3.4 YARN CONSTRUCTION (ASTM D1244) A/A20 A2 Warp 167 Dtex x1 167 Dtex x1 (polyester, false t

10、wist, (polyester false twist texturized) Texturized 100% recycled yarn) Weft 167Dtex x2, 167 Dtex x2, (polyester, false twist (polyester false twist texturized) Texturized 100% recycled yarn) 3.5 METHOD OF DYEING Solution dyed or as approved by Materials Engineering, 3.6 FINISHED OPERATIONS Wash, co

11、ating, drying, brushing (optional 4. GENERAL INFORMATION The information given below is provided for clarification and assistance in meeting the requirements of this specification. Contact for questions concerning Engineering Material Specifications. 4.1 Purchase departments will ensure that the ma

12、terial defined in this specification and shipped to any one assembly plant will be produced by one supplier only. 4.2 If yarn is locally sourced it must meet the above fabric construction, composition and yarn construction. The fabric must also meet the requirements of WSS-M8P18-A1/A2/A3/A4. 4.3 Global strategy for this fabric is to use tri-laminate/foam & scrim construction in all regions

展开阅读全文
相关资源
猜你喜欢
  • DIN EN 61770-2010 Electric appliances connected to the water mains - Avoidance of backsiphonage and failure of hose-sets (IEC 61770 2008) German version EN 61770 2009《与总水管连接的电气器具 避.pdf DIN EN 61770-2010 Electric appliances connected to the water mains - Avoidance of backsiphonage and failure of hose-sets (IEC 61770 2008) German version EN 61770 2009《与总水管连接的电气器具 避.pdf
  • DIN EN 61772-2013 Nuclear power plants - Control rooms - Application of visual display units (VDUs) (IEC 61772 2009) German version EN 61772 2013《核电站 控制室 直观显示装置(VDUs)的应用(IEC 61772-.pdf DIN EN 61772-2013 Nuclear power plants - Control rooms - Application of visual display units (VDUs) (IEC 61772 2009) German version EN 61772 2013《核电站 控制室 直观显示装置(VDUs)的应用(IEC 61772-.pdf
  • DIN EN 61784-1-2015 Industrial communication networks - Profiles - Part 1 Fieldbus profiles (IEC 61784-1 2014) English version EN 61784-1 2014 only on CD-ROM《工业通信网络 配置文件 第1部分 现场总线配.pdf DIN EN 61784-1-2015 Industrial communication networks - Profiles - Part 1 Fieldbus profiles (IEC 61784-1 2014) English version EN 61784-1 2014 only on CD-ROM《工业通信网络 配置文件 第1部分 现场总线配.pdf
  • DIN EN 61784-2-2015 Industrial communication networks - Profiles - Part 2 Additional fieldbus profiles for real-time networks based on ISO IEC 8802-3 (IEC 61784-2 2014) English ver.pdf DIN EN 61784-2-2015 Industrial communication networks - Profiles - Part 2 Additional fieldbus profiles for real-time networks based on ISO IEC 8802-3 (IEC 61784-2 2014) English ver.pdf
  • DIN EN 61784-3-1-2012 Industrial communication networks - Profiles - Part 3-1 Functional safety fieldbuses - Additional specifications for CPF 1 (IEC 61784-3-1 2010) English versio.pdf DIN EN 61784-3-1-2012 Industrial communication networks - Profiles - Part 3-1 Functional safety fieldbuses - Additional specifications for CPF 1 (IEC 61784-3-1 2010) English versio.pdf
  • DIN EN 61784-3-12-2012 Industrial communication networks - Profiles - Part 3-12 Functional safety fieldbuses - Additional specifications for CPF 12 (IEC 61784-3-12 2010) English ve.pdf DIN EN 61784-3-12-2012 Industrial communication networks - Profiles - Part 3-12 Functional safety fieldbuses - Additional specifications for CPF 12 (IEC 61784-3-12 2010) English ve.pdf
  • DIN EN 61784-3-13-2012 Industrial communication networks - Profiles - Part 3-13 Functional safety fieldbuses - Additional specifications for CPF 13 (IEC 61784-3-13 2010) English ve.pdf DIN EN 61784-3-13-2012 Industrial communication networks - Profiles - Part 3-13 Functional safety fieldbuses - Additional specifications for CPF 13 (IEC 61784-3-13 2010) English ve.pdf
  • DIN EN 61784-3-14-2012 Industrial communication networks - Profiles - Part 3-14 Functional safety fieldbuses - Additional specifications for CPF 14 (IEC 61784-3-14 2010) English ve.pdf DIN EN 61784-3-14-2012 Industrial communication networks - Profiles - Part 3-14 Functional safety fieldbuses - Additional specifications for CPF 14 (IEC 61784-3-14 2010) English ve.pdf
  • DIN EN 61784-3-18-2012 Industrial communication networks - Profiles - Part 3-18 Functional safety fieldbuses - Additional specifications for CPF 18 (IEC 61784-3-18 2011) English ve.pdf DIN EN 61784-3-18-2012 Industrial communication networks - Profiles - Part 3-18 Functional safety fieldbuses - Additional specifications for CPF 18 (IEC 61784-3-18 2011) English ve.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1