GME 60252-2009 The Determination of Indentation Hardness by Means of a Durometer (Shore A and D) (English German This standard may be applied only for current projects It is Supercced.pdf

上传人:postpastor181 文档编号:754936 上传时间:2019-01-19 格式:PDF 页数:11 大小:107KB
下载 相关 举报
GME 60252-2009 The Determination of Indentation Hardness by Means of a Durometer (Shore A and D) (English German This standard may be applied only for current projects It is Supercced.pdf_第1页
第1页 / 共11页
GME 60252-2009 The Determination of Indentation Hardness by Means of a Durometer (Shore A and D) (English German This standard may be applied only for current projects It is Supercced.pdf_第2页
第2页 / 共11页
GME 60252-2009 The Determination of Indentation Hardness by Means of a Durometer (Shore A and D) (English German This standard may be applied only for current projects It is Supercced.pdf_第3页
第3页 / 共11页
GME 60252-2009 The Determination of Indentation Hardness by Means of a Durometer (Shore A and D) (English German This standard may be applied only for current projects It is Supercced.pdf_第4页
第4页 / 共11页
GME 60252-2009 The Determination of Indentation Hardness by Means of a Durometer (Shore A and D) (English German This standard may be applied only for current projects It is Supercced.pdf_第5页
第5页 / 共11页
点击查看更多>>
资源描述

1、Issue/Ausgabe: 2Date of Issue/Ausgabedatum: 07/09Prepared/Ausgefertigt: KMAPage ofSeite 1 von 11LBSP GME PVS 2 11/95ENGINEERINGSTANDARDSEUROPETEST METHODPRFVERFAHRENThe Determination of Indentation Hardness by Means of a Durometer(Shore A and D)Hrteprfung nach Shore A und D GME 60252Note: This stand

2、ard may be applied only for current projects. It is Superceded for all global futureprojects and replaced by see following transition.Hinweis: Diese Spezifikation darf nur noch fr laufende Projekte angewendet werden und ist fr allezuknftigen globalen Projekte ungltig und ersetzt durch siehe berleitu

3、ng.Transition / berleitungOld Reference / alter BezugNew Reference / Neuer BezugFor vulcanized rubber plastics incl. thermoplastic rubberand eboniteHardness to GME 60252 Shore A Hardness to ISO 7619 1 Shore A Hardness to ISO 868 Shore AHardness to GME 60252 Shore D XXXXXXXXXXXXXXXXX Hardness to ISO

4、868 Shore DRevisions/nderungenDate/Datum Description/Beschreibung Approved/Genehmigt08/JUL/2009 was issue 1; date of issue 03/76 / set to Superseded /war Ausgabe 1; Ausgabedatum 03/76 /Status auf Superseded“ gesetztJKRApproved/GenehmigtJrg Kruse Ralf LangendorfAdam Opel GmbHGME Specification CenterA

5、dam Opel GmbHGME EngineeringDespite spot checks possibly performed by the receiver, it is the suppliers responsibility that the delivered parts are in line with thesespecifications. Deliveries of samples, first off-tool parts and parts, the performance of which has been changed, must be accompanied

6、by atest report showing the test results in terms of figures./Unbeschadet etwaiger durch den Abnehmer erfolgenden Stichprobenprfungen trgt der Lieferant die Verantwortung dafr, da diegelieferte Ware diese Vorschriften erfllt. Ein Prfbericht mit zahlenmigen Ergebnissen aus Prfungen der Lieferung selb

7、st, ist bei jederBemusterung, Erstbelieferung und Ausfhrungsnderung mitzugeben.ENGINEERINGSTANDARDSEUROPETEST METHODPRFVERFAHREN GME 60252Issue/Ausgabe: 2Date of Issue/Ausgabedatum: 07/09Prepared/Ausgefertigt: KMAPage ofSeite 2 von 11This test method is similar to those described in:ASTM D 2240 68BS

8、 2719 56DIN 53505ISO Recommendation R 868 - 19681 ScopeThe object of this test method is the rapid determination of the indentation hardness of elastomers, andthermoplastics where applicable. Preferably, this test method should be restricted to quality control purposesonly. The Shore A scale should

9、be used for the measurement within the range (3095) Shore A, andType D for hardnesses of above approximately 90 Shore A. If more accurate hardness results are requiredfor elastomers, e.g. for arbitration purposes, the ball indentation hardness (IRHD) should be determined inaccordance with GME 60256.

10、2 DefinitionsIndentation hardness is the resistance of a material to the penetration of an indentor of specified shape andsize under a specified applied force. The hardness scale runs from 0 to 100. 0 indicates zero hardness and100 indicates infinite hardness.3 Test MethodsTwo methods are available

11、for determining the indentation hardness of Elastomers and thermoplastics bymeans of a durometer.3.1 Hand held instrumentThis method is used for components having curved or divergent surfaces, or from which suitable testpieces cannot be obtained.3.2 Instrument used with a standThis method can only b

12、e used with test pieces having flat parallel surfaces.3.3 The use of the hand held instrument is restricted to quality control purposes Where the use of adurometer is unavoidable for the checking of initial samples, a suitable stand must be used.4 Test Pieces4.1 The test surfaces shall be smooth.4.2

13、 The test piece thickness shall be 6 mm minimum. Thinner material may be laminated to achieve thisthickness, provided each layer is not less than 2 mm thick, and not more than 3 layers are used. Airtrapping between layer must be avoided.4.3 The test area should be such that at least 3 readings can b

14、e obtained. The readings should be made atpoints at least 5 mm apart, and at least 12 mm from any edge.ENGINEERINGSTANDARDSEUROPETEST METHODPRFVERFAHREN GME 60252Issue/Ausgabe: 2Date of Issue/Ausgabedatum: 07/09Prepared/Ausgefertigt: KMAPage ofSeite 3 von 11Dieses Prfverfahren wurde in Anlehnung an

15、folgende internationale Empfehlungen und nationale Normenerstellt:ASTM D 2240 68BS 2719 56DIN 53505ISO Recommendation R 868 - 19681 Zweck und AnwendungDie Prfung gestattet eine schnelle der Bestimmung der Hrte an Probekrpern aus Elastomeren undThermoplasten (soweit sinnvolle Anwendung mglich) vorzug

16、sweise zur laufenden Qualittskontrolle. DasHrteprfgert Shore A wird im Bereich (30.95) Shore A angewendet. Probekrper mit Hrten ber90 Shore A werden mit dem Gert nach Shore D gemessen. Werden bei Elastomeren exaktere Mewertebentigt, z.B. in Schiedsfllen, dann wird die Kugeldruckhrte (IRHD) entsprech

17、end GME 60256 ermittelt.2 BegriffUnter der Hrte nach Shore wird der Widerstand gegen das Eindringen eines Krpers bestimmter Formunter definierter Druckkraft verstanden. Die Hrteskala umfat jeweils einen Bereich von (0.100), wobei 0der kleinsten, 100 der grten Hrte entspricht.3 PrfmethodenEs gibt zwe

18、i Mglichkeiten an Elastomeren und Thermoplasten Hrtemessungen nach Shore A und Dvorzunehmen:3.1 HandmessungSie wird an gekrmmten oder nicht planparallelen Fertigteilen vorgenommen, sowie an Fertigteilen, ausdenen keine geeigneten Prfkrper herzustellen sind.3.2 Messung mit dem StandgertMit dem Standg

19、ert sind solche Probekrper zu messen, deren Prfflchen parallel sind und keineKrmmungen aufweisen.3.3 Das Handmegert wird nur zur routinemigen laufenden Qualittskontrolle angewendet. Wenn beiErstbemusterungen die Shore- Hrte geprft werden mu, ist ein Standgert zu verwenden.4 Probekrper und Probenvorb

20、ereitung4.1 Die Prfflchen sollen glatt sein.4.2 Die Dicke der Probekrper soll 6 mm sein. Dnneres Material kann geschichtet werden, wenn dieMindestprobekrperdicke mit hchstens 3 Schichten erreicht wird. Keine dieser Schichten darf 2 mmsein. Lufteinschlsse sind zu vermeiden.4.3 Die Prfflche ist so zu

21、whlen, da mindestens 3 Messungen vorgenommen werden knnen. DerAbstand der Mepunkte untereinander ist 5 mm und zur Probekrperkante 12 mm.ENGINEERINGSTANDARDSEUROPETEST METHODPRFVERFAHREN GME 60252Issue/Ausgabe: 2Date of Issue/Ausgabedatum: 07/09Prepared/Ausgefertigt: KMAPage ofSeite 4 von 115 Conditi

22、oningFor initial sample approval, the period between vulcanization or moulding and testing of elastomers orthermoplastics shall be 7 days minimum. For routine quality control tests, the period shall be 72 h minimum.Test pieces of elastomers shall be maintained at a temperature of (+23 5) C for at le

23、ast 8 h immediatelyprior to test, and must be free from strain during this period. Test pieces of thermoplastics must be similarlyconditioned, but in addition, the relative humidity should be maintained at (50 5) % and the period extendedto 16 h.6 ApparatusThe apparatus must comply with the followin

24、g requirements:6.1 The scale must be graduated in single degrees of hardness and these graduation must be at least1 mm apart.6.2 The durometer indenter must conform to the details of the following diagrams:a (3 0,1) mm d (0,79 0,01) mmb (1,25 0,15) mm r (0,1 0,01) mmc (2,5 +0,04/-0,01) mm f (16 2,5)

25、 mmENGINEERINGSTANDARDSEUROPETEST METHODPRFVERFAHREN GME 60252Issue/Ausgabe: 2Date of Issue/Ausgabedatum: 07/09Prepared/Ausgefertigt: KMAPage ofSeite 5 von 115 ProbenvorbehandlungBei Erstbemusterungen und in Schiedsfllen ist die Prfung von Elastomeren und Thermoplasten nichtfrher als 7 Tage, fr die

26、laufende Qualittsberwachung nicht frher als 72 h nach der Vulkanisation bzw.Herstellung durchzufhren. Vor der Prfung mssen die Probekrper aus Elastomeren min 8 h imunbeanspruchten Zustand bei (+23 5) C gelagert werden. Die Probekrper aus Thermoplasten werdenmin 16 h im unbeanspruchten Zustand bei (+

27、23 5) C und (50 5) % relativer Luftfeuchte gelagert.6 PrfgerteDie Prfgerte mssen den folgenden Anforderungen entsprechen:6.1 Die Skale mu in einzelne Hrtegrade mit einem Teilstrichabstand zwischen den einzelnenHrtegraden von mindestens 1 mm geteilt sein.6.2 Die Eindringkrper der Hrteprfgerte mssen f

28、olgenden Bildern entsprechen:a (3 0,1) mm d (0,79 0,01) mmb (1,25 0,15) mm r (0,1 0,01) mmc (2,5 +0,04/-0,01) mm f (16 2,5) mmENGINEERINGSTANDARDSEUROPETEST METHODPRFVERFAHREN GME 60252Issue/Ausgabe: 2Date of Issue/Ausgabedatum: 07/09Prepared/Ausgefertigt: KMAPage ofSeite 6 von 116.3 The spring char

29、acteristic of the durometer is defined by indentor displacement caused by the forceexerted upon the indentor. The nominal values of the spring characteristic are shown in the following:6.4 A total durometer error of 1 Shore is permissible. The apparatus should be inspected at least every6 months wit

30、h a calibrating instrument.6.5 Durometer Types A and D may be provided with a stand, as an accessory into which the durometer canbe clamped. When using this stand, it is possible to press the durometer foot on to the test piecesurface with a force of 12,5 N, or 50 N for the Shore A and D ranges resp

31、ectively. It must beensured that the test piece surface and foot of the durometer are parallel.6.6 The stand is not used when manual measurements are made.6.7 If measurements are to be made at temperatures other than (+23 5) C, a suitable temperaturechamber should be used in which the test pieces sh

32、ould be conditioned according to the relevant testrequirements. The durometer will be placed into the temperature chamber immediately beforeperforming the test. If a durometer stand is used, the temperature chamber should be so constructedthat the test piece, its support, the indentor and presser-fo

33、ot will be maintained in the chamber at thetest temperature, while the indicator and spring of the durometer are external to the chamber, at atemperature of (+23 5) C. The requirements detailed in clauses 6.2 and 6.3 shall apply at all testtemperatures.Shore A 4Shore D 22,50 (2,5 +0,04/ -0,01) 55,0

34、010 130,0 445,020 205,0 890,030 280,5 1335,040 355,5 1780,050 430,5 2225,060 506,0 2670,070 581,0 3115,080 656,0 3560,090 731,0 4005,0100 0 806,5 4450,0ShoreHardnessUnitsDistancecovered byIndentermmSpring Force FcNlinear CharacteristicENGINEERINGSTANDARDSEUROPETEST METHODPRFVERFAHREN GME 60252Issue/

35、Ausgabe: 2Date of Issue/Ausgabedatum: 07/09Prepared/Ausgefertigt: KMAPage ofSeite 7 von 116.3 Die Federcharakteristik des Hrteprfgertes wird durch Aufbringen von Krften auf den Eindruckkrpergemessen. Die Sollwerte der Federcharakteristiken sind nachstehender Tabelle zu entnehmen:6.4 Fr das Hrteprfge

36、rt ist ein Gesamtfehler von 1 Shore zulssig. Die Gerte sind min alle 6 Monatemit Eichgerten zu berwachen.6.5 Zu den Hrteprfgerten nach Shore A und D gehrt als Standgert eine Zusatzeinrichtung in die dasHrteprfgert eingespannt werden kann und ein planparalleles Andrcken der Probe mit einer Kraftvon 1

37、2,5 N bei Shore A bzw. 50 N bei Shore D gestattet.6.6 Bei der Handmessung wird ausschlielich das Hrteprfgert verwandt.6.7 Wenn Messungen abweichend von (+23 5) C durchgefhrt werden sollen, sind Temperaturkammernzu verwenden. In diesen Temperaturkammern werden die Probekrper entsprechend denPrfbeding

38、ungen gelagert. Das Hrteprfgert wird erst zur Messung unmittelbar vor der Prfung in dieTemperaturkammer gebracht. Bei Messungen mit dem Standgert sind Temperierkammern zuverwenden, die so konstruiert sind, da sich der Probekrper und Probenkrperauflage sowieEindringkrper und Anlageflche des Hrteprfer

39、s in der Kammer bei Prftemperatur, das Mewerkdes Hrteprfers aber auerhalb der Kammer bei (+23 5) C befinden. Die in Pos. 6.2 und 6.3geforderten Abmessungen und zulssigen Abweichungen mssen bei allen Prftemperatureneingehalten werden.Shore A 4Shore D 22,50 (2,5 +0,04/ -0,01) 55,0 010 130,0 445,020 20

40、5,0 890,030 280,5 1335,040 355,5 1780,050 430,5 2225,060 506,0 2670,070 581,0 3115,080 656,0 3560,090 731,0 4005,0100 0 806,5 4450,0Shore-Hrte-EinheitenWegdesEindringkrpersmmFederkraft FcNgeradlinige CharakteristikENGINEERINGSTANDARDSEUROPETEST METHODPRFVERFAHREN GME 60252Issue/Ausgabe: 2Date of Iss

41、ue/Ausgabedatum: 07/09Prepared/Ausgefertigt: KMAPage ofSeite 8 von 117 Procedure7.1 The test is normally carried out at a temperature of (+23 5) C. When other temperatures arespecified, the tolerance on temperature will normally be 2,5 C. Test pieces should reach the testtemperature before being tes

42、ted, or such other time should elapse as is specified. The tolerance on testtemperature is extended to 5 C while the test is in progress.7.2 Hardness readings-should be made in at least 3 points on the test piece, subject to the requirements ofclause 4.3.7.3 The presser foot of the durometer should

43、be pressed against the test piece surface with just sufficientpressure to ensure even contact. Sudden shocks to the instrument must be avoided. If the shape ordimensions of the test piece are such that the stand cannot be used, the durometer should be hand-held. In this case, a possible error of 3 S

44、hore A or D may arise.7.4 Read the gauge 3 seconds after the presser foot and test piece have come into contact.8 Expression of ResultsThe indentation hardness is reported in Shore A or D degrees, and reference should be made to thisspecification. The hardness is taken as the median value of at leas

45、t 3 readings, and shall be a wholenumber. (The median value is the middle value of a series of results arranged in increasing order ofmagnitude, e.g. the median value of 52, 53, 56 is 53) The median value, including a tolerance of: 1 Shore for the test using the stand,and 3 Shore for a hand held dur

46、ometer.must fall within the hardness values, including any tolerances, specified on the relevant engineering drawingor material specification. If the median value deviates by more than twice the tolerance of 1 Shore or 3Shore when using the stand- supported or hand- held durometer respectively, from

47、 the upper or lowerextreme result, then the extreme value(s) should be included in the report.9 Coding SystemOn engineering drawings and in material specifications the shore- hardness is specified as follows e.g.:“Hardness to GME 60252 - (50 5) Shore A“specified RequirementSpecificationDesignationEN

48、GINEERINGSTANDARDSEUROPETEST METHODPRFVERFAHREN GME 60252Issue/Ausgabe: 2Date of Issue/Ausgabedatum: 07/09Prepared/Ausgefertigt: KMAPage ofSeite 9 von 117 Durchfhrung7.1 Die Prfung wird bei (+23 5) C durchgefhrt. Bei Prftemperaturen abweichend von (+23 5) C istan der Probe whrend des Temperierens eine Abweichung von 2,5 C vom Sollwert zulssig. Vor derPrfung sind die Proben solange in der Temperierkammer zu halten, bis sich diese an diePrftemperatur angeglichen haben. Whrend der Prfung ist eine Temperaturvernderung von 5 Cvom Sollwert an der Probe zulssig.7.2 Unter Einhaltung d

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1