1、GM DAEWOO Auto & Technology EDS Engineering GM DAEWOO Auto & Technology Standards ROUND PLUG CONNECTIONS Do Not Use on New Programs. Being Replaced by GMW3172 EDS-T-5212 ISSUED DATE: 1995. 03. 14 REVISED DATE: 2008. 10. 21 VERSION: 3 (Superceded) EDS-T-5212ROUND PLUG CONNECTIONS PAGE: 1/4 ISSUED DAT

2、E: 1995. 03. 14 REVISED DATE: 2008. 10. 21 VERSION: 3 GM DAEWOO Auto & Technology Note: This standard may be applied only for current project (incl. T255 Program). It is Superceded for all future projects and replaced by GMW3172 1. PURPOSE Following test spec. determines the general test conditions

3、for round plug connections. 2. TEST QUANTITY For the sampling, respective 20 round plug connections are to be tested, which should be struck preferably on cables corresponding to the use in the vehicle. The number of test specimen for the quality control is determined by the receipt inspection. 3. D

4、EFINITIONS 3.1. Round plug connection or releasable connection, composed of round plug and round socket. 3.2. Not releasable connection, composed of round plug or round socket with solderless struck wires. 3.3. Traction relief. Cover plate on round socket and round plug, which must be crimped so tha

5、t the insulation of the wire is tightly surrounded. 4. DELIVERY STATE Round plug and round socket are delivered as component piece, in band type or on cable according to order - example to ON 5583. Parts with smooth surface, burrfree, and without cracks, folds or grooves. The striking of round plug

6、and round socket on the wire is done with special - striking machines and hand pilers. 5. DIMENSIONS AND SURFACE TREATMENT According to specifications to ON 5583 and drawing. EDS-T-5212ROUND PLUG CONNECTIONS PAGE: 2/4 ISSUED DATE: 1995. 03. 14 REVISED DATE: 2008. 10. 21 VERSION: 3 GM DAEWOO Auto & T

7、echnology 6. MATERIALS According to material specifications to ON 5583 and drawing. 7. MECHANICAL REQUIREMENTS The forces according to 7.1.1 to 7.1.3 are to be measured after 1 - and after 10 - times plug - in connection of round socket on a belonging round plug. The measurement is performed with a

8、round plug, thickness of which corresponds to the nominal dimension and locking groove of which, if available, is changed so that the round socket is to be slided on the plug for the measuring of axial shifting force. 7.1. Releasable connection. The specified values are valid for single plug connect

9、ions. 7.1.1. Plug - in force of round socket on the round plug 1.6 : 2.5 N and 8 N 3.55 : 6.0 N and 15 N 40 : 8.0 N and 30 N 5.0 : 10.0 N and 50 N 7.1.2. Extracting force of round socket from round plug. 1.6 : 2.5 N and 9.5 N 3.55 : 6 N and 10 N 4.0 : 10 N and 30 N 5.0 : 10 N and 40 N 7.1.3. Axial s

10、hifting force 2.5 N 7.2. Not releasable connection. The extracting force of wire from the crimp connection of round socket and round plug is ascertained through a tensile test by means of tensile testing machine with a speed of holding grip 100 mm / min. For determining the extracting force, the fas

11、tening cover for the wire insulation must be detached. EDS-T-5212ROUND PLUG CONNECTIONS PAGE: 3/4 ISSUED DATE: 1995. 03. 14 REVISED DATE: 2008. 10. 21 VERSION: 3 GM DAEWOO Auto & Technology 1 2 3 min extracting force in N for nominal size Nominal cross section of wire mm2Norminal size of round plug

12、in mm 1.6 3.55 4, ou . 5,O0.5 0.75 1 1.5 2.5 4 1.6 1.6 1.6 - - - - - - 3.55 3.55 3.55 4.0 4.0 4.0 4.0 - - 5.0 5.0 5.0 5.0 5.0 - 80 100 120 - - - - - - 200 250 320 90 130 180 250 300 - Extracting forces of crimp connections. 8. ELECTRICAL REQUIREMENTS 8.1. Voltage drop 8.1.1. Voltage drop between rou

13、nd plug and inserted round socket (to be ascertained at the current - loads maximum permissible under clause 8.2 for the respective plug connection and tr = +23 5K) : 1 m V / A 8.1.2. Voltage drop between wire and round socket or round plug (to be ascertained at 5A/mm2wire cross section and tr = +23

14、 5K) : 7 m V EDS-T-5212ROUND PLUG CONNECTIONS PAGE: 4/4 ISSUED DATE: 1995. 03. 14 REVISED DATE: 2008. 10. 21 VERSION: 3 GM DAEWOO Auto & Technology Round plug 1.6 mm Round plug 3.55, 4 and 5 mm Struck wire - cross section (mm2) max. permissible current load (A) 0,5 0,75 1,0 1,5 2,5 4,0 6 8 8 - - - 8

15、 10 12 16 20 26 8.2. Loading capacity The electric loading capacity of a round plug connection is dependent on the crimped wire - cross section, on the material, on the surface cover of plug connector, the ambient temperature and the heat of a apparatus - internal heat source conducted over the roun

16、d plug. (e.g. contactor heating or hot spot at switches) The limit values for the current loading of a single plug connection determined in following table may not be exceeded. When inserting the plug and socket in higher ambient temperature or/and in multiple plug housing the current loading capaci

17、ty is reduced with increasing number of electrically loaded plug. Besides, the thermal resistance-limit of plug housing-material has an influence on the current loading capacity. The max. permissible current load of plug connection at raised temperature or/and insertion in the multiple plug housing

18、must be individually investigated or is to be taken from the technical documents of plug maker. 9. CORROSION TEST The corrosion test of joined connection is to be performed with the salt spray test according to EDS-T-7143. The voltage drops may not exceed the values to section 8.1 according to this test.

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1