ICEA S-75-381-2008 Portable and Power Feeder Cables for Use in Mines and Similar Applications (JOINT PUBLICATION - NEMA WC 58 ICEA S-75-381)《矿山及类似场所用轻便电缆和电力馈线电缆标准[用途 NEMA WC 58、NEM.pdf

上传人:sofeeling205 文档编号:783237 上传时间:2019-01-24 格式:PDF 页数:100 大小:359.34KB
下载 相关 举报
ICEA S-75-381-2008 Portable and Power Feeder Cables for Use in Mines and Similar Applications (JOINT PUBLICATION - NEMA WC 58 ICEA S-75-381)《矿山及类似场所用轻便电缆和电力馈线电缆标准[用途 NEMA WC 58、NEM.pdf_第1页
第1页 / 共100页
ICEA S-75-381-2008 Portable and Power Feeder Cables for Use in Mines and Similar Applications (JOINT PUBLICATION - NEMA WC 58 ICEA S-75-381)《矿山及类似场所用轻便电缆和电力馈线电缆标准[用途 NEMA WC 58、NEM.pdf_第2页
第2页 / 共100页
ICEA S-75-381-2008 Portable and Power Feeder Cables for Use in Mines and Similar Applications (JOINT PUBLICATION - NEMA WC 58 ICEA S-75-381)《矿山及类似场所用轻便电缆和电力馈线电缆标准[用途 NEMA WC 58、NEM.pdf_第3页
第3页 / 共100页
ICEA S-75-381-2008 Portable and Power Feeder Cables for Use in Mines and Similar Applications (JOINT PUBLICATION - NEMA WC 58 ICEA S-75-381)《矿山及类似场所用轻便电缆和电力馈线电缆标准[用途 NEMA WC 58、NEM.pdf_第4页
第4页 / 共100页
ICEA S-75-381-2008 Portable and Power Feeder Cables for Use in Mines and Similar Applications (JOINT PUBLICATION - NEMA WC 58 ICEA S-75-381)《矿山及类似场所用轻便电缆和电力馈线电缆标准[用途 NEMA WC 58、NEM.pdf_第5页
第5页 / 共100页
点击查看更多>>
资源描述

1、 Approved as an American National Standard ANSI Approval Date: May 1, 2008 NEMA Standard Publication No. WC 58-2008 ICEA Standard Publication No. S-75-381-2008 Portable and Power Feeder Cables for Use in Mines and Similar Applications Published by: National Electrical Manufacturers Association 1300

2、North 17thStreet, Suite 1752 Rosslyn, Virginia 22209 www.nema.org Copyright 2008 by the National Electrical Manufacturers Association and the Insulated Cable Engineers Association. All rights including translation into other languages, reserved under the Universal Copyright Convention, the Berne Con

3、vention for the Protection of Literary and Artistic Works, and the International and Pan American Copyright Conventions. NOTICE AND DISCLAIMER The information in this publication was considered technically sound by the consensus of persons engaged in the development and approval of the document at t

4、he time it was developed. Consensus does not necessarily mean that there is unanimous agreement among every person participating in the development of this document. The National Electrical Manufacturers Association (NEMA) standards and guidelines publications, of which the document contained herein

5、 is one, are developed through a voluntary consensus standards development process. This process brings together volunteers and/or seeks out the views of person who have an interest in the topic covered by this publication. While NEMA administers the process and establishes rules to promote fairness

6、 in the development of consensus, it does not write the document and it does not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards and guideline publications. NEMA disclaims liability for any personal

7、injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. NEMA disclaims and makes no guarantee or warranty, expressed or implied, a

8、s to the accuracy or completeness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. NEMA does not undertake to guarantee the performance of any individual manufacturer or sellers produ

9、cts or services by virtue of this standard or guide. In publishing and making this document available, NEMA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else.

10、Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. Information and other standards on the topic covered by this publication may be ava

11、ilable from other sources, which the user may wish to consult for additional views or information not covered by this publication. NEMA has no power, nor does it undertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or inspect products, designs, o

12、r installations for safety or health purposes. Any certification or other statement of compliance with any health or safety-related information in this document shall not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement. ANSI/NEMA WC 58-2008 ICEA S-

13、75-381-2008 Page i Copyright 2008 by the National Electrical Manufacturers Association and the Insulated Cable Engineers Association CONTENTS Page Foreword .vi Section 1 GENERAL . 1 1.1 Scope. 1 Portable Cables 2,000 Volts or Less. 1 Portable Cables 2,0015,000 Volts (100% Insulation Level) 1 Portabl

14、e Cables 025,000 Volts (100% Insulation Level). 1 Mine Power 2,00125,000 Volts (100% and 133% Insulation Level) . 1 1.2 General Information. 2 1.3 Information to be Supplied by User. 2 Section 2 CONDUCTORS. 3 2.1 Physical and Electrical Properties. 3 2.1.1 Copper Conductors. 3 2.1.2 Aluminum Conduct

15、ors. 3 2.1.3 Flexible Conductors 3 2.2 Conductor Size Units. 3 2.3 Conductor DC Resistance per Unit Length. 4 2.3.1 Direct Measurement of DC Resistance per Unit Length. 4 2.3.2 Calculation of DC Resistance per Unit Length . 4 2.4 Conductor Diameter 4 Section 3 PORTABLE SINGLE AND MULTIPLE CONDUCTOR

16、POWER CABLE . 12 3.1 Scope. 12 3.2 DC Systems. 12 3.3 Single-Conductor Cables, Nonshielded, 2,000 Volts or Less . 12 3.4 Type W And G Two-Conductor Cables, 2,000 Volts or Less 12 3.4.1 Two-Conductor Flat Twin Cables 12 3.4.2 Two-Conductor Round Cables 13 3.5 Type W, G, G-GC and G-CGC. Three- and Fou

17、r-Conductor Cables, 2,000 Volts or Less 13 3.5.1 Three- and Four-Conductor, Round Type W Cables without Grounding Conductors 13 3.5.2 Three- and Four-Conductor Round Type G Cables with Grounding Conductors 13 3.5.3 Three-Conductor Flat Type G Cable with Grounding Conductors 13 3.5.4 Three-Conductor

18、Flat G-GC Cable with Grounding Conductor and Ground-Check Conductor 14 3.5.5 Three-Conductor Round Type G-GC and Type G-CGC Cable 14 3.5.6 Four-Conductor Flat Type W Cable Without Grounding Conductors . 14 3.6 Type W AND G, Five- and Six-Conductor, 2,000 Volts or Less 14 3.6.1 Five- And Six-Conducto

19、r Round Type W Cables without Grounding Conductor . 14 3.6.2 Five-Conductor Round Type G Cables with Grounding Conductor 15 3.7 Type PG, Two- and Three-Conductors with Grounding Conductor, 2,000 Volts or Less. 15 3.8 Type PCG, Two- and Three-Conductors with Grounding Conductor and Two Control Conduc

20、tors, 2,000 Volts or Less . 15 3.9 Type G, Three-Conductor Round with Grounding Conductors 2,001-5,000 Volts . 15 3.10 Shielded Cable 25,000 Volts or Less 15 3.10.1 Shielded Cables 2,000 Volts or Less 15 3.10.2 Shielded Cables 2,001 to 5,000 Volts. 17 3.10.3 Shielded Cables 5,001 to 25,000 Volts. 19

21、 3.11 Power Conductors. 20 3.12 Control and Ground-Check Conductors 20 3.12.1 Control Conductors for Type PCG and SHD-PCG Cables. 20 3.12.2 Ground-Check Conductors . 20 3.12.3 Ground-Check Conductor for Flat G-GC 20 ANSI/NEMA WC 58-2008 ICEA S-75-381-2008 Page ii Copyright 2008 by the National Elect

22、rical Manufacturers Association and the Insulated Cable Engineers Association 3.13 Grounding Conductors 20 3.13.1 Size and Number 20 3.13.2 Flat Twin Type G. 21 3.13.3 Flat Three-Conductor Type G . 21 3.13.4 Round Type G, G-GC and G-CGC . 21 3.13.5 Flat Three-Conductor Type G-GC 21 3.13.6 Round Five

23、-Conductor Type G, Type PG, and PCG 21 3.14 Stress Control Layer (Conductor Shield) 22 3.14.1 Extruded Stress Control Layer (Conductor Shield). 22 3.15 Power Conductor Insulation 22 3.15.1 Insulation Physical and Electrical Requirements 22 3.15.2 Insulation Thickness 22 3.16 Ground Check and Control

24、 Conductor Insulation . 23 3.17 Tapes and Braids 23 3.17.1 Power Conductors. 23 3.17.2 Ground Check and Control Conductors 24 3.18 Conductor Identification. 27 3.18.1 Power Conductors. 27 3.18.2 Control and Ground-check Conductors 27 3.19 Shielding 27 3.19.1 Metallic Braid Shields 28 3.19.2 Metal Wi

25、re Shields 28 3.20 Conductor Assembly . 28 3.21 Jackets. 29 3.21.1 Duty Rating 29 3.21.2 General 29 3.21.3 Thickness of Jacket. 29 3.22 Completed Cable. 29 3.22.1 Outside Diameters 29 3.22.2 Diameter Tolerances. 29 3.22.3 Marking 30 3.22.4 Tests 30 SECTION 4 CONSTRUCTIONS OF MINE POWER FEEDER CABLE

26、. 49 4.1 Scope. 49 4.2 General Requirements 49 4.3 Conductors 49 4.3.1 Power Conductors. 49 4.3.2 Conductor Stress Control Layer 50 4.3.3 Grounding Conductors 50 4.3.4 Ground-check Conductor 50 4.4 Insulation . 50 4.4.1 Power Conductor 50 4.4.2 Ground-check Conductor 50 4.5 Insulation Shielding . 50

27、 4.5.1 Nonmetallic Covering 50 4.5.2 Metal Component 51 4.6 Identification 52 4.7 Conductor Assembly . 52 4.8 Jacket 52 4.9 Outside Diameter. 52 4.10 Tests 52 ANSI/NEMA WC 58-2008 ICEA S-75-381-2008 Page iii Copyright 2008 by the National Electrical Manufacturers Association and the Insulated Cable

28、Engineers Association Section 5 SPECIAL CONSTRUCTIONS 58 5.1 Portable Arc-Welding Cables 58 5.1.1 Scope 58 5.1.2 Conductor 58 5.1.3 Separator. 58 5.1.4 Jackets 58 5.1.5 Number of Wires, Outside Diameters, and Diameter Tolerances 58 5.1.6 Flame Test Requirements. 58 Section 6 TESTING AND TEST METHODS

29、. 63 6.1 Testing. 63 6.2 Tests on Samples 63 6.3 Conductor Test Methods . 63 6.3.1 Method for DC Resistance Determination 63 6.3.2 Methods for Cross-sectional Area Determination. 63 6.3.3 Methods for Diameter Determination 64 6.4 Test Samples and Specimens fFor Physical and Aging Tests . 64 6.4.1 Ge

30、neral 64 6.4.2 Number of Thickness Measurements . 64 6.4.3 Measurement of Thickness. 64 6.4.4 Sampling of Insulation for Physical and Aging Tests 64 6.4.5 Sampling of Jacket for Physical and Aging Tests. 64 6.4.6 Number of Test Specimens. 64 6.4.7 Size of Specimens 65 6.4.8 Preparation of Specimens

31、of Insulation and Jacket 65 6.4.9 Specimens with Thin Jackets Crosslinked to Insulation . 65 6.4.10 Specimen for the Tear Test. 65 6.4.11 Specimen for Accelerated Aging Test. 66 6.4.12 Calculation of Area of Test Specimens. 66 6.4.13 Physical Test Procedures . 66 6.4.14 Aging Test . 66 6.4.15 Physic

32、al Tests for Semi Conducting Material Intended for Extrusion. 67 6.4.16 Retests for Physical and Aging Properties and Thickness . 67 6.5 Capacity and Power Factor Tests . 68 6.6 Accelerated Water Absorption. 68 6.6.1 General 68 6.6.2 Electrical Method (EM-60). 68 6.7 Surface Resistance . 68 6.8 Thic

33、kness of Tapes . 68 6.9 Heat (Deformation) Distortion 68 6.10 Heat Shock 69 6.11 Cold Bend 69 6.12 Hot Creep Test 69 6.13 Solvent Extraction 69 6.14 Volume Resistivity . 69 6.14.1 Test Samples 69 6.15 Stripping Test 69 6.16 Retests for Tests Covered by 6.6 through 6.15 and 6.17.4 70 6.17 Electrical

34、Tests on Completed Cables 70 6.17.1 Voltage Tests 70 6.17.2 Insulation Resistance 71 6.17.3 Partial-Discharge Test Procedure. 71 6.18 Method Determining Permittivity (S.I.C.) and Dielectric Strength of Extruded Nonconducting Polymeric Stress Control Layers 71 ANSI/NEMA WC 58-2008 ICEA S-75-381-2008

35、Page iv Copyright 2008 by the National Electrical Manufacturers Association and the Insulated Cable Engineers Association Annexes A (Informative) Symbols and Abbreviations 72 B (Normative) Definitions for Maximum Temperature of Conductors in Insulated Wire and Cable 73 C (Normative) Emergency Overlo

36、ad Ratings for Insulated Cables 74 D (Normative) ICEA Publications, ASTM, NEMA Standards and NFPA 75 E (Informative) Shielding 78 F (Informative) Minimum Bending Radius for Cables. 80 J Informative) Voltage Test after Installation 85 K (Informative) Additional Conductor Information . 86 Tables 2-1 W

37、eight Increment Factors, K. 5 2-2 Schedule for Establishing Maximum DC Resistance 6 2-3 Nominal DC Resistance in Ohms per 1,000 Feet at 25 C of Concentric Lay Stranded Conductors 7 2-4 Nominal DC Resistance in Ohms per 1,000 Feet at 25 C for Flexible Annealed Copper Conductors 8 2-5 Nominal Diameter

38、s for Copper and Aluminum Conductors 10 2-6 Factors for Determining Nominal Resistance of Stranded Conductors per 1,000 Feet at 25 C 11 3-1 Power Conductor Insulation Requirements. 25 3-2 Ground-Check and Control Conductor Insulation Requirements . 26 3-3 Extra-Heavy-Duty Crosslinked Jackets and The

39、rmoplastic Polyurethane 32 3-4 Heavy-Duty Crosslinked Jackets. 33 3-5 Maximum Length of Lay 33 3-6 2,000 Volts or Less Single-Conductor Portable Power Cable 34 3-7 2,000 Volts or Less Type W and G Two-Conductor Flat Twin Portable Power Cables 35 3-8 2,000 Volts or Less Type W and G Two-Conductor Rou

40、nd Portable Power Cables 35 3-9 2,000 Volts or Less Type W and G Three-Conductor Round Portable Power Cables . 36 3-10 2,000 Volts or Less Type W and G Four-Conductor Round Portable Power Cables . 36 3-11 2,000 Volts or Less Type G Three-Conductor Flat Portable Power Cables with Two Grounding Conduc

41、tors 37 3-12 2,000 Volts or Less Type G-GC Three-Conductor Round Portable Power Cables with Two Grounding Conductors and One Ground-Check Conductor . 37 3-13 2,000 Volts or Less Type G-GC Three Conductor Round Portable Power Cables with Three Grounding Conductors and One Ground-Check Conductor 38 3-

42、14 2,000 Volts or Less Type G-GC Three-Conductor Flat Portable Power Cables with One Grounding Conductor and One Ground-Check Conductor. 38 3-15 2,000 Volts or Less Type W Four-Conductor Flat Portable Power Cables. 39 3-16 2,000 Volts or Less Type W And G, Five- and Six-Conductor Round Portable Powe

43、r Cables39 3-17 2,000 Volts or Less Type PG Two- and Three-Conductor Round Portable Power Cables 39 3-18 2,000 Volts or Less Type PCG Two- and Three-Conductor Round Portable Power Cables . 40 ANSI/NEMA WC 58-2008 ICEA S-75-381-2008 Page v Copyright 2008 by the National Electrical Manufacturers Assoc

44、iation and the Insulated Cable Engineers Association 3-19 2,001 To 5,000 Volts Type G Three-Conductor Round Portable Power Cables 40 3-20 Type SH Single-Conductor Portable Power Cables for 100 Percent Insulation Level Only. 41 3-21 2,000 Volts or Less Type SHC-GC Three-Conductor Round Portable Power

45、 Cables for 100 Percent Insulation Level Only 42 3-22 Type SHD And SHD-GC Three-Conductor Round Portable Power Cables for 100 Percent Insulation Level Only . 43 3-23 Type SHD-CGC Three-Conductor Portable Power Cables with Three Grounding Conductors and One Ground-Check Conductor. 45 3-24 Jacket Thic

46、knesses for Types fnd Sizes of Round Portable Cables not Covered by Tables 3-6 through 3-23 and 3-26 46 3-25 Conductors 47 3-26 Type SHD-PCG Cable. 48 3-27 2,000 Volts or Less Type SHD-Flat Three Conductor Portable Power Cable with Two Grounding Conductors 48 Tables 4-1 Conductor Sizes 53 4-2 Insula

47、tion Thicknesses and Outside Diameters2,001 to 5,000 Volts 100 and 133 Percent Insulation Levels 53 4-3 Insulation Thicknesses and Outside Diameters 5,001 to 8,000 Volts. 54 4-4 Insulation Thicknesses and Outside Diameters 8,001 to 15,000 Volts. 54 4-5 Insulation Thicknesses and Outside Diameters 15

48、,001 to 25,000 Volts. 55 4-6 Partial Discharge Extinction Voltage .55 4-7 Overall Jacket Thickness 55 4-8 Nominal DC Resistance of Medium Hard-Drawn Coated and Uncoated Copper Conductors Concentric Stranded, Class B and C. 56 4-9 Thermoplastic Jacket Requirements. 57 5-1 Heavy-Duty Jackets (Type A)

49、60 5-2 Medium-Duty Jackets (Type B) .61 5-3 Construction Details 62 6-1 Number of Samples. 63 6-2 Number of Test Specimens. 65 H-1 Ampacities for Portable Power Cables, Amperes per Power Conductor 83 I-1 Ampacities for Three-Conductor Mine Power Cables. 84 J-1 DC Test Voltages after Installation, kV 85 K-1 Concentric Stranded Class B Aluminum and Copper Conductors . 86 K-2 Concentric Stranded Class C and D Aluminum and Copper Conductors. 87 K-3 Rope-Lay Copper Conductors Class G. 88 K-4 Rope-Lay Copper Conductors Class H. 89 K-5 Copper Conductors C

展开阅读全文
相关资源
猜你喜欢
  • ASTM E756-2005(2017) 0000 Standard Test Method for Measuring Vibration-Damping Properties of Materials《测量材料减振动特性的标准试验方法》.pdf ASTM E756-2005(2017) 0000 Standard Test Method for Measuring Vibration-Damping Properties of Materials《测量材料减振动特性的标准试验方法》.pdf
  • ASTM E759 E759M-1992(2015)e1 0459 Standard Test Method for Effect of Deflection on Sprayed Fire-Resistive Material Applied to Structural Members《挠曲对结构构件上喷涂的防火材料影响的标准试验方法》.pdf ASTM E759 E759M-1992(2015)e1 0459 Standard Test Method for Effect of Deflection on Sprayed Fire-Resistive Material Applied to Structural Members《挠曲对结构构件上喷涂的防火材料影响的标准试验方法》.pdf
  • ASTM E759-1992(2005) Standard Test Method for Effect of Deflection on Sprayed Fire-Resistive Material Applied to Structural Members《挠曲对结构构件上喷涂的防火材料影响的试验方法》.pdf ASTM E759-1992(2005) Standard Test Method for Effect of Deflection on Sprayed Fire-Resistive Material Applied to Structural Members《挠曲对结构构件上喷涂的防火材料影响的试验方法》.pdf
  • ASTM E759-1992(2011) 9375 Standard Test Method for Effect of Deflection on Sprayed Fire-Resistive Material Applied to Structural Members《挠曲对结构构件上喷涂的防火材料影响的标准试验方法》.pdf ASTM E759-1992(2011) 9375 Standard Test Method for Effect of Deflection on Sprayed Fire-Resistive Material Applied to Structural Members《挠曲对结构构件上喷涂的防火材料影响的标准试验方法》.pdf
  • ASTM E760 E760M-1992(2015)e1 0492 Standard Test Method for Effect of Impact on Bonding of Sprayed Fire-Resistive Material Applied to Structural Members《冲击对结构构件上喷涂的防火材料粘结性影响的标准试验方法》.pdf ASTM E760 E760M-1992(2015)e1 0492 Standard Test Method for Effect of Impact on Bonding of Sprayed Fire-Resistive Material Applied to Structural Members《冲击对结构构件上喷涂的防火材料粘结性影响的标准试验方法》.pdf
  • ASTM E760-1992(2005) Standard Test Method for Effect of Impact on Bonding of Sprayed Fire-Resistive Material Applied to Structural Members《冲击结构构件上喷涂防火材料粘着力影响的试验方法》.pdf ASTM E760-1992(2005) Standard Test Method for Effect of Impact on Bonding of Sprayed Fire-Resistive Material Applied to Structural Members《冲击结构构件上喷涂防火材料粘着力影响的试验方法》.pdf
  • ASTM E760-1992(2011) 6250 Standard Test Method for Effect of Impact on Bonding of Sprayed Fire-Resistive Material Applied to Structural Members《构件上喷涂防火材料粘着力影响的标准试验方法》.pdf ASTM E760-1992(2011) 6250 Standard Test Method for Effect of Impact on Bonding of Sprayed Fire-Resistive Material Applied to Structural Members《构件上喷涂防火材料粘着力影响的标准试验方法》.pdf
  • ASTM E761 E761M-1992(2015)e1 0526 Standard Test Method for Compressive Strength of Sprayed Fire-Resistive Material Applied to Structural Members《结构构件上喷涂防火材料抗压强度的标准试验方法》.pdf ASTM E761 E761M-1992(2015)e1 0526 Standard Test Method for Compressive Strength of Sprayed Fire-Resistive Material Applied to Structural Members《结构构件上喷涂防火材料抗压强度的标准试验方法》.pdf
  • ASTM E761-1992(2005) Standard Test Method for Compressive Strength of Sprayed Fire-Resistive Material Applied to Structural Members《结构构件上喷涂防火材料抗压强度的试验方法》.pdf ASTM E761-1992(2005) Standard Test Method for Compressive Strength of Sprayed Fire-Resistive Material Applied to Structural Members《结构构件上喷涂防火材料抗压强度的试验方法》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1