1、IES Lighting Handbook 10th Edition, Errata As of November 23, 2015 TENTH EDITION HANDBOOK ERRATA If you, as a user of the IES Lighting Handbook, 10th Edition, believe you have located an error not covered by the following revision s, you should e-mail your information to Pat McGillicuddy at: pmcgill

2、icuddyies.ors or send a letter to: Pat McGillicuddy, Manager of Technology, IES, 120 Wall Street. 17th Floor, New York, NY 10005. Additions will be posted to this list as they become available. This errata list was last updated on November 23, 2015. Color headings indicate the latest postings. Pleas

3、e confine your comments to specific typographical errors or misstatements of fact in the Handbook text and/or graphics. Do not attempt to revise or update the Handbook itself. _ Chapter 1, page 1.12 Following Equation 1.8: The term “Kelvin” should be pluralized and the “k” should only be uppercase w

4、hen the abbreviation is used. Chapter 2, page 2.3, section 2.1.1.6 The text here says that the photosensitive ganglion cells do not receive signals from classical photoreceptors. Elsewhere in the Handbook it is stated (i.e., section 2.1.3.4, p. 2.7), correctly, that they do. Page 2.6, Figure 2.5 Dis

5、tribution of Rods and Cones in the Human Retina Replace the original Figure 2.5: IES Lighting Handbook 10th Edition, Errata As of November 23, 2015 With this revised image, showing that there is no visual cone receptor response in the retina where the optic nerve exits the eye: Page 2.15, Figure 2.1

6、1 The Red-Green Channel (L + S vs. S) should be (L + S vs. M) Page 2.23 References 23 and 24 are incomplete. Could they refer to: Rea, M. S., J. D. Bullough, J. P. Freyssinier-Nova and A. Bierman. 2004. A proposed unified system of photometry. Lighting Research and Technology 36(2): 85-111; and Good

7、man, T., A. Forbes, H. Walkey, M. Eloholma, L. Halonen, J. Alferdinck, A. Freiding, P. Bodrogi, G. Vrady, and A. Szalmas. 2007. Mesopic visual efficiency IV: A model with relevance to nighttime driving and other applications. Lighting Research and Technology 39(4): 365-392. IES Lighting Handbook 10t

8、h Edition, Errata As of November 23, 2015 Chapter 4, page 4.14, section 4.4.2 In the second to the last sentence the word “decreases” should be “decreased.” Page 4.23 References in first paragraph (39, 50, 51, 52) should be (39, 40, 41,42) Chapter 5, page 5.9 The equation in Section 5.5.2 Scotopic L

9、uminous Flux Current Equation 1700 0()() 1700 750=400()() New Version 1700 0()() 1700 750=400()() Chapter 6, page 6.18 In the third paragraphs 7th line, the term “kelvin” should be pluralized. In the sidebar adjacent to this text, the phrase “kelvin scale” should use an uppercase “K” (“Kelvin scale”

10、) to be consistent with NIST and SI usage. Chapter 6, page 6.25 In equation (6.2), the constant is now listed as 0.0547. The correct value for the constant is 0.0547. Chapter 6, page 6.26 Table 6.8, Colorimetric Properties for Some Lamps; the second column title, “Fig. 6.21 Label” should read, “Fig.

11、 20 Label”. Chapter 7, page 7.1, section 7.1.1 In the first sentence the number in scientific notation should be superscripted (109). Chapter 7, Figure 7.12 Reverse Ekh Clear and Ekh Overcast in the diagram. Chapter 8, page 8.13, Table 8.2 IES Lighting Handbook 10th Edition, Errata As of November 23

12、, 2015 The Secondary Solid Angle UM should be UL. Chapter 10, page 10.35, Section 10.9.2, Equation 10.36 The equation number (10.36) appears in error as the 1st term on the left side. The equation should begin: exp(.Rather than 10.36 exp(. Page 10.7, Equation 10.8 Remove D2 in the middle expression.

13、 Chapter 10, Section 10.9.1 Calculating Average Illuminance, page 10.33 Equation (10.28) = ( ) Should be reversed with Equation (10.29) = ( ) Page 10.39, Equation 10F10.2 Reverse ys and zs in diagram Page 10.43, Equation F10.22 Current equation 2 = (tan (2 ) = tan (2 ) New version 2 = (tan(2 )2 = ta

14、n(2 )2 Page 10.44, Equation F10.24 IES Lighting Handbook 10th Edition, Errata As of November 23, 2015 Current equation 42 = (tan(4 ) = tan(4 ) New version 4 = (tan(24 )2cos(450) = tan(4 )(2)(cos (450) Chapter 13, page 13.12, Figure 13.3 The labeling of the blue and green lines is reversed. The blue

15、line (the system having longest lifetime, no matter the operating cycle) should be for “Program start ballast with high performance T8 lamps.” The green line should be for “instant start ballast with high performance T8 lamps.” Chapter 14, page 14.61, Equation F14.8 In equation F14.8 the middle term

16、 Rw in the numerator should be replaced with Rb. Chapter 18, page 18.4 In equation 18.2 the I and “A” are switched. It should be = 100% I Chapter 18, page 18.10, Table 18.3 In equation (25.7) the (1-r) in the denominator should be (i-r); Current Equation = (1+r)(1+)(1+)(1+)(1+) (18.7) New Equation =

17、 (1+r)(1+)(1+)(+)(1+) (18.7) In the case where i=r, the equation reduces to: P=Ay The equation numbers in Table 18.3 are incorrect. Equation (25.5) should be (18.5), equation (25.6) should be (18.6), equation (25.7) should be (18.7), equation (25.8) should be (18.8), and equation (25.9) should be (1

18、8.9). Chapter 27, Table 27.2, page 27.16, Health Care Facilities Illuminance Recommendations IES Lighting Handbook 10th Edition, Errata As of November 23, 2015 Nurses Stations: Work Surface Current recommendation Ehfloor:Ev5 AFF Change to Ehwork surface; Ev5 AFF Under Nurses Stations/Surgery Pre- and Post Op/Work Station, the horizontal illuminance should read, “Ehwork surface”.