ISA 75 08 07-2001 Face-to-Face Dimensions for Separable Flanged Globe-Style Control Valves (Classes 150 300 and 600)《可分离式凸缘球状控制阀体的面到面尺寸(等级150 300和600)》.pdf

上传人:花仙子 文档编号:789776 上传时间:2019-01-31 格式:PDF 页数:14 大小:221.83KB
下载 相关 举报
ISA 75 08 07-2001 Face-to-Face Dimensions for Separable Flanged Globe-Style Control Valves (Classes 150 300 and 600)《可分离式凸缘球状控制阀体的面到面尺寸(等级150 300和600)》.pdf_第1页
第1页 / 共14页
ISA 75 08 07-2001 Face-to-Face Dimensions for Separable Flanged Globe-Style Control Valves (Classes 150 300 and 600)《可分离式凸缘球状控制阀体的面到面尺寸(等级150 300和600)》.pdf_第2页
第2页 / 共14页
ISA 75 08 07-2001 Face-to-Face Dimensions for Separable Flanged Globe-Style Control Valves (Classes 150 300 and 600)《可分离式凸缘球状控制阀体的面到面尺寸(等级150 300和600)》.pdf_第3页
第3页 / 共14页
ISA 75 08 07-2001 Face-to-Face Dimensions for Separable Flanged Globe-Style Control Valves (Classes 150 300 and 600)《可分离式凸缘球状控制阀体的面到面尺寸(等级150 300和600)》.pdf_第4页
第4页 / 共14页
ISA 75 08 07-2001 Face-to-Face Dimensions for Separable Flanged Globe-Style Control Valves (Classes 150 300 and 600)《可分离式凸缘球状控制阀体的面到面尺寸(等级150 300和600)》.pdf_第5页
第5页 / 共14页
点击查看更多>>
资源描述

1、 AMERICAN NATIONAL STANDARD ANSI/ISA-75.08.07-2001 (R2013) Face-to-Face Dimensions for Separable Flanged Globe-Style Control Valves (Classes 150, 300, and 600) Approved 31 January 2013 ANSI/ISA-75.08.07-2001 (R2013) Face-to-Face Dimensions for Separable Flanged Globe-Style Control Valves (Classes 15

2、0, 300, and 600) ISBN: 978-0-876640-00-5 Copyright 2013 by ISA. All rights reserved. Not for resale. Printed in the United States of America. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means (electronic mechanical, photocopying,

3、recording, or otherwise), without the prior written permission of the Publisher. ISA 67 Alexander Drive P.O. Box 12277 Research Triangle Park, North Carolina 27709 - 3 - ANSI/ISA-75.08.07-2001 (R2013) Preface This preface, as well as all footnotes and annexes, is included for information purposes an

4、d is not part of ANSI/ISA-75.08.07-2001 (R2013). This document has been prepared as part of the service of ISA towards a goal of uniformity in the field of instrumentation. To be of real value, this document should not be static but should be subject to periodic review. Toward this end, the Society

5、welcomes all comments and criticisms and asks that they be addressed to the Secretary, Standards and Practices Board; ISA; 67 Alexander Drive; P. O. Box 12277; Research Triangle Park, NC 27709; Telephone (919) 549-8411; Fax (919) 549-8288; E-mail: standardsisa.org. The ISA Standards and Practices De

6、partment is aware of the growing need for attention to the metric system of units in general, and the International System of Units (SI) in particular, in the preparation of instrumentation standards. The Department is further aware of the benefits to USA users of ISA standards of incorporating suit

7、able references to the SI (and the metric system) in their business and professional dealings with other countries. Toward this end, this Department will endeavor to introduce SI-acceptable metric units in all new and revised standards, recommended practices, and technical reports to the greatest ex

8、tent possible. IEEE/ASTM SI 10, American National Standard for Metric Practice, and future revisions, will be the reference guide for definitions, symbols, abbreviations, and conversion factors. It is the policy of ISA to encourage and welcome the participation of all concerned individuals and inter

9、ests in the development of ISA standards, recommended practices, and technical reports. Participation in the ISA standards-making process by an individual in no way constitutes endorsement by the employer of that individual, of ISA, or of any of the standards, recommended practices, and technical re

10、ports that ISA develops. CAUTION ISA DOES NOT TAKE ANY POSITION WITH RESPECT TO THE EXISTENCE OR VALIDITY OF ANY PATENT RIGHTS ASSERTED IN CONNECTION WITH THIS DOCUMENT, AND ISA DISCLAIMS LIABILITY FOR THE INFRINGEMENT OF ANY PATENT RESULTING FROM THE USE OF THIS DOCUMENT. USERS ARE ADVISED THAT DET

11、ERMINATION OF THE VALIDITY OF ANY PATENT RIGHTS, AND THE RISK OF INFRINGEMENT OF SUCH RIGHTS, IS ENTIRELY THEIR OWN RESPONSIBILITY. PURSUANT TO ISAS PATENT POLICY, ONE OR MORE PATENT HOLDERS OR PATENT APPLICANTS MAY HAVE DISCLOSED PATENTS THAT COULD BE INFRINGED BY USE OF THIS DOCUMENT AND EXECUTED

12、A LETTER OF ASSURANCE COMMITTING TO THE GRANTING OF A LICENSE ON A WORLDWIDE, NON-DISCRIMINATORY BASIS, WITH A FAIR AND REASONABLE ROYALTY RATE AND FAIR AND REASONABLE TERMS AND CONDITIONS. FOR MORE INFORMATION ON SUCH DISCLOSURES AND LETTERS OF ASSURANCE, CONTACT ISA OR VISIT WWW.ISA.ORG/STANDARDSP

13、ATENTS. OTHER PATENTS OR PATENT CLAIMS MAY EXIST FOR WHICH A DISCLOSURE OR LETTER OF ASSURANCE HAS NOT BEEN RECEIVED. ISA IS NOT RESPONSIBLE FOR IDENTIFYING PATENTS OR PATENT APPLICATIONS FOR WHICH A LICENSE MAY BE REQUIRED, FOR CONDUCTING INQUIRIES INTO THE LEGAL VALIDITY OR SCOPE OF PATENTS, OR DE

14、TERMINING WHETHER ANY LICENSING TERMS OR CONDITIONS PROVIDED IN CONNECTION WITH SUBMISSION OF A LETTER OF ASSURANCE, IF ANY, OR IN ANY LICENSING AGREEMENTS ARE REASONABLE OR NON-DISCRIMINATORY. ISA REQUESTS THAT ANYONE REVIEWING THIS DOCUMENT WHO IS AWARE OF ANY PATENTS THAT MAY IMPACT IMPLEMENTATIO

15、N OF THE DOCUMENT NOTIFY THE ISA STANDARDS AND PRACTICES DEPARTMENT OF THE PATENT AND ITS OWNER. ANSI/ISA-75.08.07-2001 (R2013) - 4 - ADDITIONALLY, THE USE OF THIS DOCUMENT MAY INVOLVE HAZARDOUS MATERIALS, OPERATIONS OR EQUIPMENT. THE DOCUMENT CANNOT ANTICIPATE ALL POSSIBLE APPLICATIONS OR ADDRESS A

16、LL POSSIBLE SAFETY ISSUES ASSOCIATED WITH USE IN HAZARDOUS CONDITIONS. THE USER OF THIS DOCUMENT MUST EXERCISE SOUND PROFESSIONAL JUDGMENT CONCERNING ITS USE AND APPLICABILITY UNDER THE USERS PARTICULAR CIRCUMSTANCES. THE USER MUST ALSO CONSIDER THE APPLICABILITY OF ANY GOVERNMENTAL REGULATORY LIMIT

17、ATIONS AND ESTABLISHED SAFETY AND HEALTH PRACTICES BEFORE IMPLEMENTING THIS DOCUMENT. THE USER OF THIS DOCUMENT SHOULD BE AWARE THAT THIS DOCUMENT MAY BE IMPACTED BY ELECTRONIC SECURITY ISSUES. THE COMMITTEE HAS NOT YET ADDRESSED THE POTENTIAL ISSUES IN THIS VERSION. The following people served as m

18、embers of ISA Subcommittee SP75.08 and approved ANSI/ISA-75.08.07-2001: NAME COMPANY W. Weidman, Managing Director Parsons Energy & Chemicals Group H. Baumann H B Services Partners LLC G. Borden Consultant R. Brodin Fisher Controls International, Inc. F. Cain Flowserve Corp. R. Chown Otec Process Sy

19、stems, Inc. B. Hatton DeZurik Division Unit J. Reed Norriseal H. Sonderegger Anvil International, Inc. The following persons served as members of ISA Committee SP75 and approved ANSI/ISA-75.08.07-2001: NAME COMPANY W. Weidman, Managing Director Parsons Energy & Chemicals Group D. Buchanan, Chairman

20、Union Carbide Corp. A. Abromaitis Red Valve Co., Inc. H. Backinger Consultant G. Barb Consultant H. Baumann H B Services Partners LLC J. Beall Eastman Chemical Co. W. Black Cashco, Inc. W. Blackwell Industrial Valve H. Boger Masoneilan Dresser G. Borden Consultant S. Boyle Metso Automation USA, Inc.

21、 R. Brodin Fisher Controls International, Inc. F. Cain Flowserve Corp. A. Engels Praxair, Inc. H. Fuller Valvcon Corp. J. George Richards Industries L. Griffith Consultant D. Grunenberg Richards Industries J. Jamison Bantrel, Inc. R. Jeanes TXU Electric J. Kersh M W Kellogg Co. C. Langford Cullen G.

22、 Langford, Inc. - 5 - ANSI/ISA-75.08.07-2001 (R2013) W. Lestan Dresser Valve Division A. Libke DeZurik Valve Co. R. Louviere Services Unlimited J. McCaskill Power Chokes A. McCauley Chagrin Valley Controls, Inc. R. McEver Emerson Valve Automation H. Miller Control Components, Inc. T. Molloy CMES, In

23、c. L. Ormanoski Frick Co. J. Ozol Northern States Power W. Rahmeyer Utah State University J. Reed Norriseal K. Schoonover Con-Tek Valves, Inc. A. Shea DeZurik/Copes-Vulcan E. Skovgaard Leslie Controls, Inc. H. Sonderegger Anvil International, Inc. _ * One vote per company. ANSI/ISA-75.08.07-2001 was

24、 approved for publication by the ISA Standards and Practices Board on 04 April 2001. NAME COMPANY M. Zielinski Fisher-Rosemount Systems, Inc. D. Bishop Consultant P. Brett Honeywell, Inc. M. Cohen Senior Flexonics, Inc. M. Coppler Ametek, Inc. B. Dumortier Schneider Electric SA W. Holland Southern C

25、ompany A. Iverson Ivy Optiks R. Jones Dow Chemical Co. V. Maggioli Feltronics Corp. T. McAvinew Instrumentation & Control Engineering LLC A. McCauley, Jr. Chagrin Valley Controls, Inc. G. McFarland Westinghouse Process Control Inc. D. Rapley Rapley Consulting Inc. R. Reimer Rockwell Automation J. Re

26、nnie Factory Mutual Research Corp. H. Sasajima Advanced Architecture and Technologies R. Webb Altran Corp. W. Weidman Parsons Energy & Chemicals Group J. Weiss EPRI J. Whetstone National Institute of Standards & Technology M. Widmeyer EG&G Defense Materials R. Wiegle CANUS Corp. C. Williams Eastman

27、Kodak Co. G. Wood Graeme Wood Consulting ANSI/ISA-75.08.07-2001 (R2013) - 6 - The following people served as members of ISA Subcommittee ISA75.08 and reaffirmed ANSI/ISA-75.08.04-2001 (R2013): NAME COMPANY W. Weidman, Chair WCW Consulting H. Baumann H B Services Partners LLC G. Borden Consultant F.

28、Cain Flowserve Corporation R. Chown Madawaska Mechanical Inc. R. Duimstra Fisher Controls International Inc. V. Mezzano Fluor Corporation J. Reed Consultant J. Young The Dow Chemical Company The following people served as members of ISA Committee ISA75 and reaffirmed 14 January 2013 ANSI/ISA-75.08.0

29、4-2001 (R2013): NAME COMPANY J. Young, Chair The Dow Chemical Company W. Weidman, Managing Director WCW Consulting L. Al-Awami Saudi Aramco H. Baumann H B Services Partners LLC J. Beall Emerson Process Management M. Bober Copes-Vulcan H. Boger GE Oil & Gas G. Borden Consultant S. Boyle Metso Automat

30、ion USA Inc. J. Broyles Enbridge Pipelines Inc. F. Cain Flowserve Corporation R. Duimstra Fisher Controls International Inc. J. Faramarzi Control Components Inc. J. George Richards Industries C. Hergert Kellogg Brown & Root H. Hoffmann Consultant J. Jamison Spectra Energy Ltd. J. Kiesbauer Samson Ak

31、tiengesellschaft A. Libke DeZurik G. Liu Consultant T. Loudin Flowrox Inc. H. Maxwell Bechtel Power Corp. J. McCaskill Expro Group A. McCauley Chagrin Valley Controls Inc. R. McEver Consultant V. Mezzano Fluor Corporation H. Miller Consultant T. Molloy CMES Inc. L. Ormanoski Consultant J. Reed Consu

32、ltant E. Skovgaard Control Valve Solutions - 7 - ANSI/ISA-75.08.07-2001 (R2013) This standard was approved for reaffirmation by the ISA Standards and Practices Board on 2013: NAME COMPANY D. Dunn, Vice President Aramco Services Co. R. Bartusiak ExxonMobil Chemical Company P. Brett Honeywell Inc. J.

33、Campbell Consultant M. Coppler Det Norske Veritas Certification Inc. E. Cosman The Dow Chemical Co. B. Dumortier Schneider Electric J. Federlein Federlein & Assoc. Inc. J. Gilsinn Kenexis Consulting E. Icayan ACES Inc. J. Jamison Spectra Energy Ltd. K. Lindner Endress+Hauser Process Solutions AG V.

34、Maggioli Feltronics Corp. T. McAvinew Instrumentation and Control Engineering LLC R. Reimer Rockwell Automation S. Russell Valero Energy Corp. N. Sands DuPont H. Sasajima Azbil Corp. T. Schnaare Rosemount Inc. J. Tatera Tatera & Associates Inc. I. Verhappen Industrial Automation Networks Inc. W. Wei

35、dman WCW Consulting J. Weiss Applied Control Solutions LLC M. Wilkins Yokogawa IA Global Marketing (USMK) D. Zetterberg Chevron Energy Technology Company This page intentionally left blank. - 9 - ANSI/ISA-75.08.07-2001 (R2013) CONTENTS 1 Scope . 11 2 Purpose 11 3 Definition 11 4 Dimensional data . 1

36、1 5 References . 12 This page intentionally left blank. - 11 - ANSI/ISA-75.08.07-2001 (R2013) 1 Scope This standard applies to separable flanged globe-style control valves, sizes 1 inch through 4 inches. 2 Purpose The purpose of this standard is to aid users in their piping design by providing Class

37、es 150, 300, and 600 raised face separable flanged control valve dimensions without giving special consideration to the equipment manufacturer to be used. 3 Definition 3.1 separable flanges: non-integral loose flanges held to the vessel/valve by mechanical means such as retaining rings or swaged rim

38、s. 4 Dimensional data For face-to-face dimensions for separable flange globe-style control valves, see Table 1. Table 1 Face-to-face dimensions Nominal valve size Class 150, 300, 600 Tolerance Dimension A mm inches mm inches mm inches 25 1 216 8.50 1.6 0.062 40 1 1/2 241 9.50 1.6 0.062 50 2 292 11.5

39、0 1.6 0.062 80 3 356 14.00 1.6 0.062 100 4 432 17.00 1.6 0.062 NOTE This standard does not preclude the user from purchasing separable flange control valves with face-to-face dimensions different from those given in ANSI/ISA-75.08.01-2002 (R2007). ANSI/ISA-75.08.07-2001 (R2013) - 12 - 5 References T

40、he following references are included for the definition of pressure classes, flange dimensions, material identification, and cross reference information. American Society of Mechanical Engineers (ASME) ASME B16.5-2003 Pipe Flanges and Flanged Fittings ASME B16.34-2004 Valves-Flanged, Threaded, and W

41、elding End Available from: ASME Three Park Avenue New York, NY 10016-5990 Tel: 212-591-7000 http:/www.asme.org ISA ANSI/ISA-75.08.01-2002 Face-to-Face Dimensions for Flanged Globe-Style Control Valve Bodies (R2007) (Classes 125, 150, 250, 300, and 600) Available from: ISA 67 Alexander Drive PO Box 1

42、2277 Research Triangle Park, NC 27709 Tel: 919-549-8411 http:/www.isa.org Developing and promulgating sound consensus standards, recommended practices, and technical reports is one of ISAs primary goals. To achieve this goal the Standards and Practices Department relies on the technical expertise an

43、d efforts of volunteer committee members, chairmen and reviewers. ISA is an American National Standards Institute (ANSI) accredited organization. ISA administers United States Technical Advisory Groups (USTAGs) and provides secretariat support for International Electrotechnical Commission (IEC) and

44、International Organization for Standardization (ISO) committees that develop process measurement and control standards. To obtain additional information on the Societys standards program, please write: ISA Attn: Standards Department 67 Alexander Drive P.O. Box 12277 Research Triangle Park, NC 27709 ISBN: 978-0-876640-00-5

展开阅读全文
相关资源
猜你喜欢
  • DIN EN 62037-1-2013 Passive RF and microwave devices intermodulation level measurement - Part 1 General requirements and measuring methods (IEC 62037-1 2012) German version EN 6203.pdf DIN EN 62037-1-2013 Passive RF and microwave devices intermodulation level measurement - Part 1 General requirements and measuring methods (IEC 62037-1 2012) German version EN 6203.pdf
  • DIN EN 62037-2-2013 Passive RF and microwave devices intermodulation level measurement - Part 2 Measurement of passive intermodulation in coaxial cable assemblies (IEC 62037-2 2012.pdf DIN EN 62037-2-2013 Passive RF and microwave devices intermodulation level measurement - Part 2 Measurement of passive intermodulation in coaxial cable assemblies (IEC 62037-2 2012.pdf
  • DIN EN 62037-3-2013 Passive RF and microwave devices intermodulation level measurement - Part 3 Measurement of passive intermodulation in coaxial connectors (IEC 62037-3 2012) Germ.pdf DIN EN 62037-3-2013 Passive RF and microwave devices intermodulation level measurement - Part 3 Measurement of passive intermodulation in coaxial connectors (IEC 62037-3 2012) Germ.pdf
  • DIN EN 62037-4-2013 Passive RF and microwave devices intermodulation level measurement - Part 4 Measurement of passive intermodulation in coaxial cables (IEC 62037-4 2012) German v.pdf DIN EN 62037-4-2013 Passive RF and microwave devices intermodulation level measurement - Part 4 Measurement of passive intermodulation in coaxial cables (IEC 62037-4 2012) German v.pdf
  • DIN EN 62037-5-2013 Passive RF and microwave devices intermodulation level measurement - Part 5 Measurement of passive intermodulation in filters (IEC 62037-5 2013) German version .pdf DIN EN 62037-5-2013 Passive RF and microwave devices intermodulation level measurement - Part 5 Measurement of passive intermodulation in filters (IEC 62037-5 2013) German version .pdf
  • DIN EN 62037-6-2013 Passive RF and microwave devices intermodulation level measurement - Part 6 Measurement of passive intermodulation in antennas (IEC 62037-6 2013) German version.pdf DIN EN 62037-6-2013 Passive RF and microwave devices intermodulation level measurement - Part 6 Measurement of passive intermodulation in antennas (IEC 62037-6 2013) German version.pdf
  • DIN EN 62040-1-2013 Uninterruptible power systems (UPS) Part 1 General and safety requirements for UPS (IEC 62040-1 2008 + Corrigendum September 2008 + A1 2013) German version EN 6.pdf DIN EN 62040-1-2013 Uninterruptible power systems (UPS) Part 1 General and safety requirements for UPS (IEC 62040-1 2008 + Corrigendum September 2008 + A1 2013) German version EN 6.pdf
  • DIN EN 62040-2-2006 Uninterruptible power systems (UPS) - Part 2 Electromagnetic compatibility (EMC) requirements (IEC 62040-2 2005) German version EN 62040-2 2006《不间断供电系统(UPS) 第2部.pdf DIN EN 62040-2-2006 Uninterruptible power systems (UPS) - Part 2 Electromagnetic compatibility (EMC) requirements (IEC 62040-2 2005) German version EN 62040-2 2006《不间断供电系统(UPS) 第2部.pdf
  • DIN EN 62040-3-2011 Uninterruptible power systems (UPS) - Part 3 Method of specifying the performance and test requirements (IEC 62040-3 2011) German version EN 62040-3 2011《不间断电源系.pdf DIN EN 62040-3-2011 Uninterruptible power systems (UPS) - Part 3 Method of specifying the performance and test requirements (IEC 62040-3 2011) German version EN 62040-3 2011《不间断电源系.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1