ITU-R BT 1664-2003 Representation of various image aspect ratios into the image of large screen digital imagery applications that use a 16 9 raster《使用16 9光栅的大屏幕数字成像应用的图像各种纵横比的表示》.pdf

上传人:diecharacter305 文档编号:790639 上传时间:2019-02-02 格式:PDF 页数:2 大小:83.19KB
下载 相关 举报
ITU-R BT 1664-2003 Representation of various image aspect ratios into the image of large screen digital imagery applications that use a 16 9 raster《使用16 9光栅的大屏幕数字成像应用的图像各种纵横比的表示》.pdf_第1页
第1页 / 共2页
ITU-R BT 1664-2003 Representation of various image aspect ratios into the image of large screen digital imagery applications that use a 16 9 raster《使用16 9光栅的大屏幕数字成像应用的图像各种纵横比的表示》.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 Rec. ITU-R BT.1664 1 RECOMMENDATION ITU-R BT.1664 Representation of various image aspect ratios into the image of large screen digital imagery1applications that use a 16:9 raster (Question ITU-R 15/6) (2003) The ITU Radiocommunication Assembly, considering a) that the advent of large screen digital

2、 imagery (LSDI) may lead to some undesirable cropping of the images that have been carefully composed, e.g. at an aspect ratio of 1.66:1 or 1.85:1, when those images are transferred onto an LSDI master with a 16:9 image aspect ratio; b) that good engineering practice demands that the creative intent

3、 should be preserved; c) that the original image composition should be preserved without cropping; d) that Recommendation ITU-R BR.1374 Scanned area dimensions from 16 mm and 35 mm cinematographic film used in television, specifically addresses ways to transfer films to video, as far as image aspect

4、 ratios are concerned, by specifying reference values for the dimensions of the area scanned on film during its transfer to television, when the film has been photographed for optical projection, recommends 1 that the original composition of programme images should be preserved in subsequent use of

5、the programme; 2 that when using an LSDI image system with an aspect ratio of 16:9 for programme presentation, images originally composed with different aspect ratios should be fitted into the 16:9 presentation image in such a way that no part of the original image is cropped, even if this results i

6、n blanking some parts of the 16:9 presentation image2. 1Large screen digital imagery (LSDI) is a family of digital imagery systems applicable to programmes such as dramas, plays, sporting events, concerts, cultural events, etc. from capture to large screen presentation in high-resolution quality in

7、appropriately equipped cinema theatres, halls and other venues. 2The examples given in Table 1 (non-normative) provide an indication of the extent to which programme images in various aspect ratios would fill the 16:9 presentation image. 2 Rec. ITU-R BT.1664 Annex 1 (non-normative) Examples of fitti

8、ng various image aspect ratios into a presentation image with a 16:9 aspect ratio Table 1 provides some non-normative examples of the way images composed with various aspect ratios can be fitted into a presentation image with a 16:9 aspect ratio, without cropping their composition. The examples assu

9、me the use of spherical projection lenses and a presentation raster of an aspect ratio of 16:93. The assumed operating practice is the following one: Programme images are adjusted to fill the presentation raster height in examples 1, 2 and 3, and to fill the presentation raster width in example 4. T

10、he areas in the presentation raster that fall outside the programme images are blanked. TABLE 1 Examples of fitting various image aspect ratios into a 16:9 presentation image 3The case of images originally composed for wider aspect ratios can be addressed by horizontally compressing those images int

11、o the 16:9 scanned raster through the use of anamorphic lenses. They are subsequently decompressed in projection through the use of complementary anamorphic lenses fitted to the digital projector. Example Original image aspect ratio Presentation Appearance 1 1.33:1 (4:3) The 16:9 presentation raster

12、 has black areas, 12.5% wide, on each side of the original image 2 1.37:1 (Academy) The 16:9 presentation raster has black areas, 11.5% wide, on each side of the original image 3 1.66:1 The 16:9 presentation raster has black areas, 3.5% wide, on each side of the original image 4 1.85:1 The 16:9 presentation raster has black areas, 2% high, at the top and bottom of the original image

展开阅读全文
相关资源
猜你喜欢
  • GOST ISO 10819-2002 Vibration and shock Method for the measurements and evaluation of the vibration transmissibility of gloves at the palm of the hand《振动与冲击 手套在手心处的振动传递率的测量和评价方法》.pdf GOST ISO 10819-2002 Vibration and shock Method for the measurements and evaluation of the vibration transmissibility of gloves at the palm of the hand《振动与冲击 手套在手心处的振动传递率的测量和评价方法》.pdf
  • GOST ISO 10968-2013 Earth-moving machinery Operator-s controls《土方机械 司机的操纵装置》.pdf GOST ISO 10968-2013 Earth-moving machinery Operator-s controls《土方机械 司机的操纵装置》.pdf
  • GOST ISO 10993-1-2011 Medical devices Biological evaluation of medical devices Part 1 Evaluation and testing《医疗器械 医疗器械的生物学评价 第1部分 评价与测试》.pdf GOST ISO 10993-1-2011 Medical devices Biological evaluation of medical devices Part 1 Evaluation and testing《医疗器械 医疗器械的生物学评价 第1部分 评价与测试》.pdf
  • GOST ISO 10993-10-2011 Medical devices Biological evaluation of medical devices Part 10 Tests for irritation and delayed-type hypersensitivity《医疗器械 医疗器械的生物学评价 第10部分 刺激与持续型过敏症试验》.pdf GOST ISO 10993-10-2011 Medical devices Biological evaluation of medical devices Part 10 Tests for irritation and delayed-type hypersensitivity《医疗器械 医疗器械的生物学评价 第10部分 刺激与持续型过敏症试验》.pdf
  • GOST ISO 10993-11-2011 Medical devices Biological evaluation of medical devices Part 11 Tests for systemic toxicity《医疗器械 医疗器械的生物学评价 第11部分 系统毒性试验》.pdf GOST ISO 10993-11-2011 Medical devices Biological evaluation of medical devices Part 11 Tests for systemic toxicity《医疗器械 医疗器械的生物学评价 第11部分 系统毒性试验》.pdf
  • GOST ISO 10993-12-2015 Medical devices Biological evaluation of medical devices Part 12 Sample preparation and reference materials《医疗器械的生物学评价 第12部分 样品制备和参考材料》.pdf GOST ISO 10993-12-2015 Medical devices Biological evaluation of medical devices Part 12 Sample preparation and reference materials《医疗器械的生物学评价 第12部分 样品制备和参考材料》.pdf
  • GOST ISO 10993-14-2011 Medical devices Biological evaluation of medical devices Part 14 Identification and quantification of degradation products from ceramics《医疗器械 医疗器械的生物学评价 第14部.pdf GOST ISO 10993-14-2011 Medical devices Biological evaluation of medical devices Part 14 Identification and quantification of degradation products from ceramics《医疗器械 医疗器械的生物学评价 第14部.pdf
  • GOST ISO 10993-15-2011 Medical devices Biological evaluation of medical devices Part 15 Identification and quantification of degradation products from metals and alloys《医疗器械 医疗器械的生.pdf GOST ISO 10993-15-2011 Medical devices Biological evaluation of medical devices Part 15 Identification and quantification of degradation products from metals and alloys《医疗器械 医疗器械的生.pdf
  • GOST ISO 10993-17-2011 Medical devices Biological evaluation of medical devices Part 17 Establishment of allowable limits for leachable substances《医疗器械 医疗器械的生物学评价 第17部分 可滤取物质允许限度的建.pdf GOST ISO 10993-17-2011 Medical devices Biological evaluation of medical devices Part 17 Establishment of allowable limits for leachable substances《医疗器械 医疗器械的生物学评价 第17部分 可滤取物质允许限度的建.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1