ITU-T H 830 10-2017 Conformance of ITU-T H 810 personal health system Services interface Part 10 hData Observation Upload Health & Fitness Service receiver (Study Group 16).pdf

上传人:figureissue185 文档编号:797912 上传时间:2019-02-02 格式:PDF 页数:20 大小:515.72KB
下载 相关 举报
ITU-T H 830 10-2017 Conformance of ITU-T H 810 personal health system Services interface Part 10 hData Observation Upload Health & Fitness Service receiver (Study Group 16).pdf_第1页
第1页 / 共20页
ITU-T H 830 10-2017 Conformance of ITU-T H 810 personal health system Services interface Part 10 hData Observation Upload Health & Fitness Service receiver (Study Group 16).pdf_第2页
第2页 / 共20页
ITU-T H 830 10-2017 Conformance of ITU-T H 810 personal health system Services interface Part 10 hData Observation Upload Health & Fitness Service receiver (Study Group 16).pdf_第3页
第3页 / 共20页
ITU-T H 830 10-2017 Conformance of ITU-T H 810 personal health system Services interface Part 10 hData Observation Upload Health & Fitness Service receiver (Study Group 16).pdf_第4页
第4页 / 共20页
ITU-T H 830 10-2017 Conformance of ITU-T H 810 personal health system Services interface Part 10 hData Observation Upload Health & Fitness Service receiver (Study Group 16).pdf_第5页
第5页 / 共20页
点击查看更多>>
资源描述

1、 I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T H.830.10 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (04/2017) SERIES H: AUDIOVISUAL AND MULTIMEDIA SYSTEMS E-health multimedia services and applications Interoperability compliance testing of personal health systems (H

2、RN, PAN, LAN, TAN and WAN) Conformance of ITU-T H.810 personal health system: Services interface Part 10: hData Observation Upload: Health Part 10: hData Observation Upload: HFS Receiver (Version 1.2, 2017-03-14). This Recommendation includes an electronic attachment with the protocol implementation

3、 conformance statements (PICS) and the protocol implementation extra information for testing (PIXIT) required for the implementation of Annex A. History Edition Recommendation Approval Study Group Unique ID* 1.0 ITU-T H.830.10 2015-11-29 16 11.1002/1000/12675 2.0 ITU-T H.830.10 2016-07-14 16 11.1002

4、/1000/12930 3.0 ITU-T H.830.10 2017-04-13 16 11.1002/1000/13205 Keywords Conformance testing, Continua Design Guidelines, e-health, hData Observation Upload, Health Part 10: hData Observation Upload: HFS Receiver (Version 1.2, 2017-03-14), that was developed by the Personal Connected Health Alliance

5、. The table below shows the revision history of this test specification; it may contain versions that existed before transposition. Version Date Revision history 1.0 2015-07-01 Initial release for Test Tool DG2015 based on the requirements in b-ITU-T H.810 (2015)/b-CDG 2015. 1.1 2016-09-20 Initial r

6、elease for Test Tool DG2016. It implements changes according to ITU-T H.810 (2016)/b-CDG 2016 (Iris + Errata) refreshments. 1.2 2017-03-14 Editorial: added insulin pump and continuous glucose monitor specializations to the TSS list in clause 6. Rec. ITU-T H.830.10 (04/2017) 1 Recommendation ITU-T H.

7、830.10 Conformance of ITU-T H.810 personal health system: Services interface Part 10: hData Observation Upload: Health users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A

8、list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation. ITU-T H.810 (2016) Recommendation ITU-T H.810 (2016), Interoperability design guidelines for p

9、ersonal health systems. ITU-T H.811 Recommendation ITU-T H.811 (2016), Interoperability design guidelines for personal health systems: Personal health devices interface. 1 This Recommendation includes an electronic attachment with the protocol implementation conformance statements (PICS) and the pro

10、tocol implementation extra information for testing (PIXIT) required for the implementation of Annex A. 2 Rec. ITU-T H.830.10 (04/2017) ITU-T H.812 Recommendation ITU-T H.812 (2016), Interoperability design guidelines for personal health systems: Services interface: Common certified capability class.

11、 ITU-T H.812.1 Recommendation ITU-T H.812.1 (2016), Interoperability design guidelines for personal health systems: Services interface: Observation upload certified capability class. ITU-T H.812.2 Recommendation ITU-T H.812.2 (2016), Interoperability design guidelines for personal health systems: Se

12、rvices interface: Questionnaires certified capability class. ITU-T H.812.3 Recommendation ITU-T H.812.3 (2016), Interoperability design guidelines for personal health systems: Services interface: Capability exchange certified capability class. ITU-T H.812.4 Recommendation ITU-T H.812.4 (2016), Inter

13、operability design guidelines for personal health systems: Services interface: Authenticated persistent session certified capability class. ITU-T H.813 Recommendation ITU-T H.813 (2016), Interoperability design guidelines for personal health systems: Healthcare information system interface. HL7 V3 H

14、RF Health Level Seven (2014), HL7 Version 3 Specification: hData Record Format, Release 1. http:/www.hl7.org/documentcenter/private/standards/v3/V3_ITS_HDATA_RF_R1_2014JUN.pdf 3 Definitions 3.1 Terms defined elsewhere None. 3.2 Terms defined in this Recommendation None. 4 Abbreviations and acronyms

15、This Recommendation uses the following abbreviations and acronyms: AHD Application Hosting Device ATNA Audit Trail and Node Authentication CDA Clinical Document Architecture CDG Continua Design Guidelines CGM Continuous Glucose Monitor DUT Device Under Test GUI Graphical User Interface HFS Health M

16、RESTSec 8;M CommonReq 5;M Spec ITU-T H.812.1 Testable items hData 6;M hData 9;M hData 10;M Test purpose Check that: SUT accepts an hData observation upload using TLS 1.1 and using a provided Oauth v2.0 bearer token for authorization. Applicability C_REC_000 AND C_REC_GEN_004 Other PICS C_REC_GEN_005

17、 Initial condition Simulated HFS application using hData observation upload has a PCD-01 message ready to be sent to the SUT using TLS 1.1 and an Oauth 2.0 bearer token provided by the SUT. Test procedure 1. Simulated HFS application requests a beater OAuth 2.0 token using the URL provided by the SU

18、T, the authorization grant type specified in PIXIT I_REC_OAUTH_001, and the required parameters specified in the test tool general parameters for the specific grant type, using a TLS 1.1 connection. 2. Simulated HFS application uses the provided bearer token to send a PCD-01 message to the URL provi

19、ded by the SUT using TLS 1.1 connection. 3. Simulated HFS application also sends an HTTP DELETE request on the observation upload URL. Pass/Fail criteria HFS application under test supports capability exchange as specified in ITU-T H.812.3. HFS device providing the authorization server returns an au

20、thorization token of type “bearer” after validating the access token request. HFS device providing the authorization server includes “refresh token” in the response to the access token request. HFS application under test returns an response when the PCD-01 message is received. HFS application return

21、s an (Method not allowed) response to an HTTP DELETE request on the observation upload URL. Notes 10 Rec. ITU-T H.830.10 (04/2017) A.3 Subgroup 2.6.2: hData record format (HRF) TP Id TP/HFS/REC/HDATA/HRF/BV-000 TP label hData Observation Upload. Root file elements Coverage Spec ITU-T H.812 Testable

22、items CommonReq 5;M Spec ITU-T H.812.1 Testable items hData 6;M hData 7;M hData 8;M Spec HL7 V3 HRF Testable items Root 9;M Root 10;M Root 11;M Root 12;M Root 13;M Root 14;M Root 15;M Root 16;M Root 18;M Root 19;M Root 20;M Root 22;M Test purpose Check that: SUT declares required and recommended obs

23、ervation upload capabilities in its root file according to hData Record Format. Applicability C_REC_000 AND C_REC_GEN_004 Other PICS C_REC_GEN_005 Initial condition Simulated HFS application using hData observation upload is ready to check the SUT hData observation upload capabilities declared in it

24、s root file. SUT has previously provided a base URL. Test procedure 1. Simulated HFS application performs an HTTP GET of root.xml using TLS v.1.1. OAuth 2.0 token is not required. 2. Simulated HFS application obtains and checks required and recommended observation upload capabilities in root.xml fil

25、e. Pass/Fail criteria HFS application under test supports capability exchange as specified in ITU-T H.812.3. HFS application provides root.xml file. Root.xml shows the capability elements for observation upload applications supporting hData as shown: observation-upload-hData http:/handle.itu.int/11.

26、1002/3000/hData/Upload/2016/01/H.812.1.pdf path/to/payload/post for hData observation-upload-hData observation observation Rec. ITU-T H.830.10 (04/2017) 11 http:/ application/txt Additionally, simulated HFS application checks that Oauth2 authentication server support capability (recommended) is as s

27、hown: oAUTH http:/handle.itu.int/11.1002/3000/hData/Upload/2016/01/H.812.1.pdf path/to/post for oAUTH token oAUTH oAUTH-Bearer http:/tools.ietf.org/html/rfc6750 application/json Notes 12 Rec. ITU-T H.830.10 (04/2017) Bibliography b-ITU-T H.810 (2013) Recommendation ITU-T H.810 (2013), Interoperabili

28、ty design guidelines for personal health systems. b-ITU-T H.810 (2015) Recommendation ITU-T H.810 (2015), Interoperability design guidelines for personal health systems. b-CDG 1.0 Continua Health Alliance, Continua Design Guidelines v1.0 (2008), Continua Design Guidelines. b-CDG 2010 Continua Health

29、 Alliance, Continua Design Guidelines v1.5 (2010), Continua Design Guidelines. b-CDG 2011 Continua Health Alliance, Continua Design Guidelines (2011), “Adrenaline“, Continua Design Guidelines. b-CDG 2012 Continua Health Alliance, Continua Design Guidelines (2012), “Catalyst“, Continua Design Guideli

30、nes. b-CDG 2013 Continua Health Alliance, Continua Design Guidelines (2013), “Endorphin“, Continua Design Guidelines. b-CDG 2015 Continua Health Alliance, Continua Design Guidelines (2015), “Genome“, Continua Design Guidelines. b-CDG 2016 Personal Connected Health Alliance, Continua Design Guideline

31、s (2016), “Iris“, Continua Design Guidelines. b-ETSI SR 001 262 ETSI SR 001 262 v1.8.1 (2003), ETSI drafting rules. https:/docbox.etsi.org/MTS/MTS/10-PromotionalMaterial/MBS-20111118/Referenced%20Documents/Drafting%20Rules.pdf b-HFSR PICS construction, installation and protection of cables and other

32、 elements of outside plant Series M Telecommunication management, including TMN and network maintenance Series N Maintenance: international sound programme and television transmission circuits Series O Specifications of measuring equipment Series P Telephone transmission quality, telephone installat

33、ions, local line networks Series Q Switching and signalling, and associated measurements and tests Series R Telegraph transmission Series S Telegraph services terminal equipment Series T Terminals for telematic services Series U Telegraph switching Series V Data communication over the telephone network Series X Data networks, open system communications and security Series Y Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities Series Z Languages and general software aspects for telecommunication systems

展开阅读全文