ITU-T H 830 9-2016 Conformance of ITU-T H 810 personal health devices WAN interface Part 9 hData observation upload Sender (Study Group 16)《ITU-T H 810的个人健康设备的一致性:广域网接口9部分:数据观察上传:发.pdf

上传人:inwarn120 文档编号:797936 上传时间:2019-02-02 格式:PDF 页数:17 大小:399.88KB
下载 相关 举报
ITU-T H 830 9-2016 Conformance of ITU-T H 810 personal health devices WAN interface Part 9 hData observation upload Sender (Study Group 16)《ITU-T H 810的个人健康设备的一致性:广域网接口9部分:数据观察上传:发.pdf_第1页
第1页 / 共17页
ITU-T H 830 9-2016 Conformance of ITU-T H 810 personal health devices WAN interface Part 9 hData observation upload Sender (Study Group 16)《ITU-T H 810的个人健康设备的一致性:广域网接口9部分:数据观察上传:发.pdf_第2页
第2页 / 共17页
ITU-T H 830 9-2016 Conformance of ITU-T H 810 personal health devices WAN interface Part 9 hData observation upload Sender (Study Group 16)《ITU-T H 810的个人健康设备的一致性:广域网接口9部分:数据观察上传:发.pdf_第3页
第3页 / 共17页
ITU-T H 830 9-2016 Conformance of ITU-T H 810 personal health devices WAN interface Part 9 hData observation upload Sender (Study Group 16)《ITU-T H 810的个人健康设备的一致性:广域网接口9部分:数据观察上传:发.pdf_第4页
第4页 / 共17页
ITU-T H 830 9-2016 Conformance of ITU-T H 810 personal health devices WAN interface Part 9 hData observation upload Sender (Study Group 16)《ITU-T H 810的个人健康设备的一致性:广域网接口9部分:数据观察上传:发.pdf_第5页
第5页 / 共17页
点击查看更多>>
资源描述

1、 I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T H.830.9 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (07/2016) SERIES H: AUDIOVISUAL AND MULTIMEDIA SYSTEMS E-health multimedia services and applications Interoperability compliance testing of personal health systems (HR

2、N, PAN, LAN, TAN and WAN) Conformance of ITU-T H.810 personal health devices: WAN interface Part 9: hData observation upload: Sender Recommendation ITU-T H.830.9 ITU-T H-SERIES RECOMMENDATIONS AUDIOVISUAL AND MULTIMEDIA SYSTEMS CHARACTERISTICS OF VISUAL TELEPHONE SYSTEMS H.100H.199 INFRASTRUCTURE OF

3、 AUDIOVISUAL SERVICES General H.200H.219 Transmission multiplexing and synchronization H.220H.229 Systems aspects H.230H.239 Communication procedures H.240H.259 Coding of moving video H.260H.279 Related systems aspects H.280H.299 Systems and terminal equipment for audiovisual services H.300H.349 Dir

4、ectory services architecture for audiovisual and multimedia services H.350H.359 Quality of service architecture for audiovisual and multimedia services H.360H.369 Telepresence H.420H.429 Supplementary services for multimedia H.450H.499 MOBILITY AND COLLABORATION PROCEDURES Overview of Mobility and C

5、ollaboration, definitions, protocols and procedures H.500H.509 Mobility for H-Series multimedia systems and services H.510H.519 Mobile multimedia collaboration applications and services H.520H.529 Security for mobile multimedia systems and services H.530H.539 Security for mobile multimedia collabora

6、tion applications and services H.540H.549 Mobility interworking procedures H.550H.559 Mobile multimedia collaboration inter-working procedures H.560H.569 BROADBAND, TRIPLE-PLAY AND ADVANCED MULTIMEDIA SERVICES Broadband multimedia services over VDSL H.610H.619 Advanced multimedia services and applic

7、ations H.620H.629 Ubiquitous sensor network applications and Internet of Things H.640H.649 IPTV MULTIMEDIA SERVICES AND APPLICATIONS FOR IPTV General aspects H.700H.719 IPTV terminal devices H.720H.729 IPTV middleware H.730H.739 IPTV application event handling H.740H.749 IPTV metadata H.750H.759 IPT

8、V multimedia application frameworks H.760H.769 IPTV service discovery up to consumption H.770H.779 Digital Signage H.780H.789 E-HEALTH MULTIMEDIA SERVICES AND APPLICATIONS Personal health systems H.810H.819 Interoperability compliance testing of personal health systems (HRN, PAN, LAN, TAN and WAN) H

9、.820H.859 Multimedia e-health data exchange services H.860H.869 For further details, please refer to the list of ITU-T Recommendations. Rec. ITU-T H.830.9 (07/2016) i Recommendation ITU-T H.830.9 Conformance of ITU-T H.810 personal health devices: WAN interface Part 9: hData observation upload: Send

10、er Summary Recommendation ITU-T H.830.9 provides a test suite structure (TSS) and the test purposes (TPs) for the WAN interface (consent management; sender) based on the requirements defined in Recommendation ITU-T H.810 (2015). The objective of this test specification is to provide a high probabili

11、ty of air interface interoperability between different devices. This Recommendation is a transposition of Continua Test Tool DG2015, Test Suite Structure (TSS) Part 9: hData observation upload: Sender (Version 1.0, 2015-07-01). This Recommendation includes an electronic attachment with the protocol

12、implementation conformance statements (PICS) and the protocol implementation extra information for testing (PIXIT) required for the implementation of Annex A. History Edition Recommendation Approval Study Group Unique ID* 1.0 ITU-T H.830.9 2015-11-29 16 11.1002/1000/12660 2.0 ITU-T H.830.9 2016-07-1

13、4 16 11.1002/1000/12929 Keywords Conformance testing, continua design guidelines, e-health, H.810, WAN interface, personal connected health devices, wide area network. * To access the Recommendation, type the URL http:/handle.itu.int/ in the address field of your web browser, followed by the Recomme

14、ndations unique ID. For example, http:/handle.itu.int/11.1002/1000/11830-en. ii Rec. ITU-T H.830.9 (07/2016) FOREWORD The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The IT

15、U Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis. The World Telecommunication Standardiz

16、ation Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics. The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1. In some areas of information tech

17、nology which fall within ITU-Ts purview, the necessary standards are prepared on a collaborative basis with ISO and IEC. NOTE In this Recommendation, the expression “Administration“ is used for conciseness to indicate both a telecommunication administration and a recognized operating agency. Complia

18、nce with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words “shall“ or some other obli

19、gatory language such as “must“ and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party. INTELLECTUAL PROPERTY RIGHTSITU draws attention to the possibility that the practice or implementatio

20、n of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process. As of

21、the date of approval of this Recommendation, had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to cons

22、ult the TSB patent database at http:/www.itu.int/ITU-T/ipr/. ITU 2016 All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU. Rec. ITU-T H.830.9 (07/2016) iii Table of Contents Page 1 Scope . 1 2 References . 1 3 Defin

23、itions 2 3.1 Terms defined elsewhere 2 3.2 Terms defined in this Recommendation . 2 4 Abbreviations and acronyms 2 5 Conventions 3 6 Test suite structure (TSS) . 4 7 Electronic attachment . 6 Annex A Test purposes . 7 A.1 TP definition conventions . 7 A.2 Subgroup 1.6.1: General (GEN) . 8 Bibliograp

24、hy. 9 Electronic attachment: This Recommendation includes an electronic attachment with the protocol implementation conformance statements (PICS) and the protocol implementation extra information for testing (PIXIT) required for the implementation of Annex A. iv Rec. ITU-T H.830.9 (07/2016) Introduc

25、tion This Recommendation is a transposition of Continua Test Tool DG2015, Test Suite Structure (TSS) Part 9: hData observation upload: Sender (Version 1.0, 2015-07-01), that was developed by the Continua Health Alliance. A version of this specification that existed before transposition is indicated

26、in the table below. Version Date Revision history 1.0 2015-07-01 Initial release for Test Tool DG2015 Rec. ITU-T H.830.9 (07/2016) 1 Recommendation ITU-T H.830.9 Conformance of ITU-T H.810 personal health devices: WAN interface Part 9: hData observation upload: sender 1 Scope The scope of this Recom

27、mendation1 is to provide test suite structure and test purposes (TSS users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations

28、is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation. ITU-T H.810 (2015) Recommendation ITU-T H.810 (2015), Interoperability design guidelines for personal health systems. ITU-T H.810 (2016) Recomme

29、ndation ITU-T H.810 (2016), Interoperability design guidelines for personal health systems. ITU-T H.811 Recommendation ITU-T H.811 (2015), Interoperability design guidelines for personal health systems: PAN/LAN/TAN interface. 1 This Recommendation includes an electronic attachment with the protocol

30、implementation conformance statements (PICS) and the protocol implementation extra information for testing (PIXIT) required for the implementation of Annex A. 2 Rec. ITU-T H.830.9 (07/2016) ITU-T H.812 Recommendation ITU-T H.812 (2015), Interoperability design guidelines for personal health systems:

31、 WAN interface: Common certified device class. ITU-T H.812.1 Recommendation ITU-T H.812.1 (2015), Interoperability design guidelines for personal health systems: WAN interface: Observation upload certified device class. ITU-T H.812.2 Recommendation ITU-T H.812.2 (2015), Interoperability design guide

32、lines for personal health systems: WAN interface: Questionnaires. ITU-T H.812.3 Recommendation ITU-T H.812.3 (2015), Interoperability design guidelines for personal health systems: WAN interface: Capability exchange device class. ITU-T H.812.4 Recommendation ITU-T H.812.4 (2015), Interoperability de

33、sign guidelines for personal health systems: WAN interface: Authenticated persistent session device class. ITU-T H.813 Recommendation ITU-T H.813 (2015), Interoperability design guidelines for personal health systems: Health record network (HRN) interface. IETF RFC 6749 IETF RFC 6749 (2012), The OAu

34、th 2.0 Authorization Framework. http:/tools.ietf.org/html/rfc6749 IETF RFC 6750 IETF RFC 6750 (2012), The OAuth 2.0 Authorization Framework: Bearer Token Usage. http:/tools.ietf.org/html/rfc6750 3 Definitions 3.1 Terms defined elsewhere None. 3.2 Terms defined in this Recommendation None. 4 Abbrevia

35、tions and acronyms This Recommendation uses the following abbreviations and acronyms: ATNA Audit Trail and Node Authentication AHD Application Hosting Device CDA Clinical Document Architecture CDG Continua Design Guidelines DUT Device Under Test GUI Graphical User Interface HL7 Health Level 7 HTTP H

36、ypertext Transfer Protocol HTTPS Hypertext Transfer Protocol Secure INR International Normalized Ratio PCHA Personal Connected Health Alliance PCD Patient Care Device Rec. ITU-T H.830.9 (07/2016) 3 PICS Protocol Implementation Conformance Statement SABTE Sleep Apnoea Breathing Therapy Equipment SOAP

37、 Simple Object Access Protocol TP Test Purpose TLS Transport Level Security TSS Test Suite Structure WAN Wide Area Network WS Web Service WSI Web Service Interoperability XDR Cross-Enterprise Document Reliable Interchange 5 Conventions The key words SHALL, SHALL NOT, SHOULD, SHOULD NOT, MAY, MAY NOT

38、 in this Recommendation are to be interpreted as in b-ETSI SR 001 262. SHALL is equivalent to must or it is required to. SHALL NOT is equivalent to must not or it is not allowed. SHOULD is equivalent to it is recommended to. SHOULD NOT is equivalent to it is not recommended to. MAY is equivalent to

39、is permitted. MAY NOT is equivalent to it is not required that. NOTE The above-mentioned key words are capitalized for illustrative purposes only and they do not appear capitalized within this Recommendation. Reference is made in the ITU-T H.800-series of Recommendations to different versions of the

40、 Continua Design Guidelines (CDG) by a specific designation. The list of terms that may be used in this Recommendation is provided in Table 1. Table 1 List of designations associated with the various versions of the CDG CDG release Transposed as Version Description Designation 2016 plus errata ITU-T

41、 H.810 (2016) 6.1 Release 2016 plus errata noting all ratified bugs ITU-T H.810 (2016). 2016 6.0 Release 2016 of the CDG including maintenance updates of the CDG 2015 and additional guidelines that cover new functionalities. Iris 2015 plus errata ITU-T H.810 (2015) 5.1 Release 2015 plus errata notin

42、g all ratified bugs ITU-T H.810 (2015). 2015 5.0 Release 2015 of the CDG including maintenance updates of the CDG 2013 and additional guidelines that cover new functionalities. Genome 2013 plus errata ITU-T H.810 (2013) 4.1 Release 2013 plus errata noting all ratified bugs b-ITU-T H.810 (2013). 4 Re

43、c. ITU-T H.830.9 (07/2016) Table 1 List of designations associated with the various versions of the CDG CDG release Transposed as Version Description Designation 2013 4.0 Release 2013 of the CDG including maintenance updates of the CDG 2012 and additional guidelines that cover new functionalities. E

44、ndorphin 2012 plus errata 3.1 Release 2012 plus errata noting all ratified bugs b-CDG 2012. 2012 3.0 Release 2012 of the CDG including maintenance updates of the CDG 2011 and additional guidelines that cover new functionalities. Catalyst 2011 plus errata 2.1 CDG 2011 integrated with identified errat

45、a. 2011 2.0 Release 2011 of the CDG including maintenance updates of the CDG 2010 and additional guidelines that cover new functionalities b-CDG 2011. Adrenaline 2010 plus errata 1.6 CDG 2010 integrated with identified errata 2010 1.5 Release 2010 of the CDG with maintenance updates of the CDG Versi

46、on 1 and additional guidelines that cover new functionalities b-CDG 2010. 1.5 1.0 1.0 First released version of the CDG b-CDG 1.0. 6 Test suite structure (TSS) The test purposes (TPs) for the WAN interface have been divided into the main subgroups specified below. Annex A describes the TPs for subgr

47、oup 1.6.1 (shown in bold): Group 1: Sender (SEN) Group 1.1: Web services interoperability (WSI) Subgroup 1.1.1: Basic profile (BP) Subgroup 1.1.2: Basic security profile (BSP) Subgroup 1.1.3: Reliable messaging (RM) Group 1.2: Simple object access protocol (SOAP) Subgroup 1.2.1: SOAP headers (HEAD)

48、Group 1.3: Audit trail and node authentication (ATNA) Subgroup 1.3.1: General (GEN) Subgroup 1.3.2: PCD-01 (PCD-01) Subgroup 1.3.3: Consent management (CM) Group 1.4: PCD-01 HL7 messages (PCD-01-DATA) Subgroup 1.4.1: General (GEN) Subgroup 1.4.2: Design guidelines (DG) Subgroup 1.4.3: Pulse oximeter

49、 (PO) Subgroup 1.4.4: Blood pressure monitor (BPM) Rec. ITU-T H.830.9 (07/2016) 5 Subgroup 1.4.5: Thermometer (TH) Subgroup 1.4.6: Weighing scales (WEG) Subgroup 1.4.7: Glucose meter (GL) Subgroup 1.4.8: Cardiovascular fitness and activity monitor (CV) Subgroup 1.4.9: Strength fitness equipment (ST) Subgroup 1.4.10: Independent living activity hub (HUB) Subgroup 1