ITU-T H 850 6-2017 Conformance of ITU-T H 810 personal health system Personal Health Devices interface Part 10F Transcoding for Bluetooth Low Energy Personal Health Gateway C Pulse.pdf

上传人:李朗 文档编号:797997 上传时间:2019-02-02 格式:PDF 页数:168 大小:1.38MB
下载 相关 举报
ITU-T H 850 6-2017 Conformance of ITU-T H 810 personal health system Personal Health Devices interface Part 10F Transcoding for Bluetooth Low Energy Personal Health Gateway C Pulse.pdf_第1页
第1页 / 共168页
ITU-T H 850 6-2017 Conformance of ITU-T H 810 personal health system Personal Health Devices interface Part 10F Transcoding for Bluetooth Low Energy Personal Health Gateway C Pulse.pdf_第2页
第2页 / 共168页
ITU-T H 850 6-2017 Conformance of ITU-T H 810 personal health system Personal Health Devices interface Part 10F Transcoding for Bluetooth Low Energy Personal Health Gateway C Pulse.pdf_第3页
第3页 / 共168页
ITU-T H 850 6-2017 Conformance of ITU-T H 810 personal health system Personal Health Devices interface Part 10F Transcoding for Bluetooth Low Energy Personal Health Gateway C Pulse.pdf_第4页
第4页 / 共168页
ITU-T H 850 6-2017 Conformance of ITU-T H 810 personal health system Personal Health Devices interface Part 10F Transcoding for Bluetooth Low Energy Personal Health Gateway C Pulse.pdf_第5页
第5页 / 共168页
点击查看更多>>
资源描述

1、 I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T H.850.6 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (04/2017) SERIES H: AUDIOVISUAL AND MULTIMEDIA SYSTEMS E-health multimedia services and applications Interoperability compliance testing of personal health systems (HR

2、N, PAN, LAN, TAN and WAN) Conformance of ITU-T H.810 personal health system: Personal Health Devices interface Part 10F: Transcoding for Bluetooth Low Energy: Personal Health Gateway Pulse oximeter Recommendation ITU-T H.850.6 ITU-T H-SERIES RECOMMENDATIONS AUDIOVISUAL AND MULTIMEDIA SYSTEMS CHARACT

3、ERISTICS OF VISUAL TELEPHONE SYSTEMS H.100H.199 INFRASTRUCTURE OF AUDIOVISUAL SERVICES General H.200H.219 Transmission multiplexing and synchronization H.220H.229 Systems aspects H.230H.239 Communication procedures H.240H.259 Coding of moving video H.260H.279 Related systems aspects H.280H.299 Syste

4、ms and terminal equipment for audiovisual services H.300H.349 Directory services architecture for audiovisual and multimedia services H.350H.359 Quality of service architecture for audiovisual and multimedia services H.360H.369 Telepresence H.420H.429 Supplementary services for multimedia H.450H.499

5、 MOBILITY AND COLLABORATION PROCEDURES Overview of Mobility and Collaboration, definitions, protocols and procedures H.500H.509 Mobility for H-Series multimedia systems and services H.510H.519 Mobile multimedia collaboration applications and services H.520H.529 Security for mobile multimedia systems

6、 and services H.530H.539 Security for mobile multimedia collaboration applications and services H.540H.549 Mobility interworking procedures H.550H.559 Mobile multimedia collaboration inter-working procedures H.560H.569 BROADBAND, TRIPLE-PLAY AND ADVANCED MULTIMEDIA SERVICES Broadband multimedia serv

7、ices over VDSL H.610H.619 Advanced multimedia services and applications H.620H.629 Ubiquitous sensor network applications and Internet of Things H.640H.649 IPTV MULTIMEDIA SERVICES AND APPLICATIONS FOR IPTV General aspects H.700H.719 IPTV terminal devices H.720H.729 IPTV middleware H.730H.739 IPTV a

8、pplication event handling H.740H.749 IPTV metadata H.750H.759 IPTV multimedia application frameworks H.760H.769 IPTV service discovery up to consumption H.770H.779 Digital Signage H.780H.789 E-HEALTH MULTIMEDIA SERVICES AND APPLICATIONS Personal health systems H.810H.819 Interoperability compliance

9、testing of personal health systems (HRN, PAN, LAN, TAN and WAN) H.820H.859 Multimedia e-health data exchange services H.860H.869 For further details, please refer to the list of ITU-T Recommendations. Rec. ITU-T H.850.6 (04/2017) i Recommendation ITU-T H.850.6 Conformance of ITU-T H.810 personal hea

10、lth system: Personal Health Devices interface Part 10F: Transcoding for Bluetooth Low Energy: Personal Health Gateway Pulse oximeter Summary Recommendation ITU-T H.850.6 provides a test suite structure (TSS) and the test purposes (TP) for the transcoding of pulse oximeter data by personal health gat

11、eways in the Personal Health Devices (PHD) interface of application-level data between the Bluetooth Low Energy Bluetooth Generic Attribute Profile (GATT) format and the IEEE 11073-20601 data format, of which Recommendation ITU-T H.810 (2016) is the base Recommendation. The objective of this test sp

12、ecification is to provide a high probability of interoperability at this interface. Recommendation ITU-T H.850.6 is a transposition of clause 3.8 of Continua Test Tool DG2016, Test Suite Structure Part 10: PHD Transcoding Whitepaper. Personal Health Gateway (Version 1.7, 2017-07-18), that was develo

13、ped by the Personal Connected Health Alliance. A number of versions of this specification existed before transposition. This Recommendation includes an electronic attachment with the protocol implementation conformance statements (PICS) and the protocol implementation extra information for testing (

14、PIXIT) required for the implementation of Annex A. This Recommendation is part of ITU-T H.850 that was originally approved in 04/2017 as a single part, but which was split at publication time into eight sub-parts for easier use, maintenance and expandability: ITU-T H.850 with the general requirement

15、s; ITU-T H.850.1 with thermometer PHD requirements; ITU-T H.850.2 with blood pressure PHD requirements; ITU-T H.850.3 with heart rate PHD requirements; ITU-T H.850.4 with glucose meter PHD requirements; ITU-T H.850.5 with weighing scales PHD requirements; ITU-T H.850.6 with pulse oximeter PHD requir

16、ements; ITU-T H.850.7 with continuous glucose monitoring PHD requirements. History Edition Recommendation Approval Study Group Unique ID* 1.0 ITU-T H.850.6 2017-04-29 16 11.1002/1000/13359 Keywords Bluetooth Generic Attribute Profile, Bluetooth Low Energy (BLE), Conformance testing, Continua Design

17、Guidelines, data format transcoding, e-health, IEEE 11073-20601, ITU-T H.810, personal area network, personal connected health devices, Personal Health Devices interface, Personal Health Gateway, pulse oximeter, touch area network. _ * To access the Recommendation, type the URL http:/handle.itu.int/

18、 in the address field of your web browser, followed by the Recommendations unique ID. For example, http:/handle.itu.int/11.1002/1000/11830-en. ii Rec. ITU-T H.850.6 (04/2017) FOREWORD The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommuni

19、cations, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunica

20、tions on a worldwide basis. The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics. The approval of ITU-T Recommendations is covered by the procedure

21、 laid down in WTSA Resolution 1. In some areas of information technology which fall within ITU-Ts purview, the necessary standards are prepared on a collaborative basis with ISO and IEC. NOTE In this Recommendation, the expression “Administration“ is used for conciseness to indicate both a telecommu

22、nication administration and a recognized operating agency. Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these

23、mandatory provisions are met. The words “shall“ or some other obligatory language such as “must“ and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party. INTELLECTUAL PROPERTY RIGHTSITU dra

24、ws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members o

25、r others outside of the Recommendation development process. As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not rep

26、resent the latest information and are therefore strongly urged to consult the TSB patent database at http:/www.itu.int/ITU-T/ipr/. ITU 2017 All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU. Rec. ITU-T H.850.6 (04

27、/2017) iii Table of Contents Page 1 Scope . 1 2 References . 2 3 Definitions 3 3.1 Terms defined elsewhere 3 3.2 Terms defined in this Recommendation . 3 4 Abbreviations and acronyms 3 5 Conventions 4 6 Test suite structure 6 7 Electronic attachment . 8 Annex A Test purposes . 9 A.1 TP definition co

28、nventions . 9 A.2 Subgroup 2.4.7 Whitepaper Pulse oximeter requirements (PLX) . 11 Bibliography. 160 Electronic attachment: This Recommendation includes an electronic attachment with the protocol implementation conformance statements (PICS) and the protocol implementation extra information for testi

29、ng (PIXIT) required for the implementation of Annex A. iv Rec. ITU-T H.850.6 (04/2017) Introduction This Recommendation is a transposition of clause 3.8 of Continua Test Tool DG2016, Test Suite Structure Part 10: PHD Transcoding Whitepaper. Personal Health Gateway (Version 1.7, 2017-07-18), that was

30、 developed by the Personal Connected Health Alliance. The table below shows the revision history of this test specification; it may contain versions that existed before transposition. Version Date Revision history 1.0 2012-10-05 Initial release for Test Tool DG2011 based on the requirements in b-CDG

31、 2011. 1.1 2013-05-24 Initial release for Test Tool DG2012. It uses “TSS users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendati

32、ons is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation. ITU-T H.810 (2016) Recommendation ITU-T H.810 (2016), Interoperability design guidelines for personal health systems. Bluetooth PHDT v1.4 Bl

33、uetooth SIG (2013), Personal Health Devices Transcoding White Paper, v1.4. https:/www.bluetooth.org/DocMan/handlers/DownloadDoc.ashx?doc_id=294539 Bluetooth PHDT v1.5 Bluetooth SIG (2014), Personal Health Devices Transcoding White Paper, v1.5. https:/www.bluetooth.org/DocMan/handlers/DownloadDoc.ash

34、x?doc_id=272346 Bluetooth PHDT v1.6 Bluetooth SIG (2015), Personal Health Devices Transcoding White Paper, v1.6. https:/www.bluetooth.org/DocMan/handlers/DownloadDoc.ashx?doc_id=310657 ISO/IEEE 11073-104xx ISO/IEEE 11073-104xx (in force), Health informatics Personal health device communication Devic

35、e specialization. NOTE Shorthand to refer to the collection of device specialization standards that utilize ISO/IEEE 11073-20601-2015A, where xx can be any number from 01 to 99, inclusive. ISO/IEEE 11073-20601-2015A ISO/IEEE 11073-20601:2010, Health informatics Personal health device communication P

36、art 20601: Application profile Optimized exchange protocol, including ISO/IEEE 11073-20601:2010 Amd 1:2015. https:/www.iso.org/standard/54331.html with https:/www.iso.org/standard/63972.html Rec. ITU-T H.850.6 (04/2017) 3 ISO/IEEE 11073-20601-2016C ISO/IEEE 11073-20601:2016, Health informatics Perso

37、nal health device communication Part 20601: Application profile Optimized exchange protocol, including ISO/IEEE 11073-20601:2016/Cor.1:2016. https:/www.iso.org/standard/66717.html with https:/www.iso.org/standard/71886.html IHE PCD TF 1 IHE PCD TF 1 (2012), IHE Patient Care Device Technical Framewor

38、k Revision 2.0. Volume 1: Integration Profiles. http:/ IHE PCD TF 2 IHE PCD TF 2 (2012), IHE Patient Care Device Technical Framework Revision 2.0. Volume 2: Transactions. http:/ IHE PCD TF 3 IHE PCD TF 3 (2012), IHE Patient Care Device Technical Framework Revision 2.0. Volume 3: Semantic Content. ht

39、tp:/ 3 Definitions 3.1 Terms defined elsewhere This Recommendation uses the following terms defined elsewhere: 3.1.1 agent ISO/IEEE 11073-20601-2016C: A node that collects and transmits personal health data to an associated manager. 3.1.2 manager ISO/IEEE 11073-20601-2016C: A node receiving data fro

40、m one or more agent systems. Some examples of managers include a cellular phone, health appliance, set top box, or a computer system. 3.2 Terms defined in this Recommendation None. 4 Abbreviations and acronyms This Recommendation uses the following abbreviations and acronyms: ATS Abstract Test Suite

41、 CDG Continua Design Guidelines CGM Continuous Glucose Monitor DUT Device Under Test GUI Graphical User Interface INR International Normalized Ratio IP Insulin Pump IUT Implementation Under Test LSB Least Significant Bit MDS Medical Device System MSB Most Significant Bit 4 Rec. ITU-T H.850.6 (04/201

42、7) NFC Near Field Communication PAN Personal Area Network PCD Patient Care Device PCO Point of Control and Observation PCT Protocol Conformance Testing PHD Personal Health Device PHDC Personal Healthcare Device Class PHG Personal Health Gateway PICS Protocol Implementation Conformance Statement PIXI

43、T Protocol Implementation extra Information for Testing RACP Record Access Control Point SABTE Sleep Apnoea Breathing Therapy Equipment SCR Static Conformance Review SDP Service Discovery Protocol SOAP Simple Object Access Protocol TCRL Test Case Reference List TCWG Test and Certification Working Gr

44、oup TP Test Purposes TSS Test Suite Structure USB Universal Serial Bus WDM Windows Driver Model 5 Conventions In this text, the uppercase letter L is used as the symbol for litre. Several of the test purposes in Annex A refer to “WAN PCD-01 messages“; these messages are specified in the patient care

45、 device (PCD) technical framework defined in IHE PCD TF 1, IHE PCD TF 2 and IHE PCD TF 3. Similarly, the “IEEE 11073 Objects and Attributes“ are defined in ISO/IEEE 11073-104xx. The key words “SHALL“, “SHALL NOT“, “SHOULD“, “SHOULD NOT“, “MAY“, “MAY NOT“ in this Recommendation are to be interpreted

46、as in b-ETSI SR 001 262. SHALL is equivalent to must or it is required to. SHALL NOT is equivalent to must not or it is not allowed. SHOULD is equivalent to it is recommended to. SHOULD NOT is equivalent to it is not recommended to. MAY is equivalent to is permitted. MAY NOT is equivalent to it is n

47、ot required that. NOTE The above-mentioned key words are capitalized for illustrative purposes only and they do not appear capitalized within this Recommendation. In this document, hexadecimal numbers are denoted either with the prefix “0x“ or by “(hex)“ after the number; “(dec)“ after a number indi

48、cates it is expressed in decimal format. Rec. ITU-T H.850.6 (04/2017) 5 Reference is made in the ITU-T H.800-series of Recommendations to different versions of the Continua Design Guidelines (CDG) by a specific designation. The list of terms that may be used in this Recommendation is provided in Table 1. Table 1 List of designations associated with the various versions of the CDG CDG release Transposed as Version Description Designation 2016 plus errata ITU-T H.810 (20

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有