ITU-T K 100-2017 Measurement of radio frequency electromagnetic fields to determine compliance with human exposure limits when a base station is put into service (Study Group 5).pdf

上传人:eventdump275 文档编号:799129 上传时间:2019-02-02 格式:PDF 页数:38 大小:1.13MB
下载 相关 举报
ITU-T K 100-2017 Measurement of radio frequency electromagnetic fields to determine compliance with human exposure limits when a base station is put into service (Study Group 5).pdf_第1页
第1页 / 共38页
ITU-T K 100-2017 Measurement of radio frequency electromagnetic fields to determine compliance with human exposure limits when a base station is put into service (Study Group 5).pdf_第2页
第2页 / 共38页
ITU-T K 100-2017 Measurement of radio frequency electromagnetic fields to determine compliance with human exposure limits when a base station is put into service (Study Group 5).pdf_第3页
第3页 / 共38页
ITU-T K 100-2017 Measurement of radio frequency electromagnetic fields to determine compliance with human exposure limits when a base station is put into service (Study Group 5).pdf_第4页
第4页 / 共38页
ITU-T K 100-2017 Measurement of radio frequency electromagnetic fields to determine compliance with human exposure limits when a base station is put into service (Study Group 5).pdf_第5页
第5页 / 共38页
点击查看更多>>
资源描述

1、 I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T K.100 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (07/2017) SERIES K: PROTECTION AGAINST INTERFERENCE Measurement of radio frequency electromagnetic fields to determine compliance with human exposure limits when a base

2、station is put into service Recommendation ITU-T K.100 Rec. ITU-T K.100 (07/2017) i Recommendation ITU-T K.100 Measurement of radio frequency electromagnetic fields to determine compliance with human exposure limits when a base station is put into service Summary Recommendation ITU-T K.100 provides

3、information on measurement techniques and procedures for assessing compliance with the general public electromagnetic field (EMF) exposure limits when a new base station (BS) is put into service, taking into account effects of the environment and other relevant radio frequency (RF) sources present i

4、n its surroundings. History Edition Recommendation Approval Study Group Unique ID* 1.0 ITU-T K.100 2014-12-07 5 11.1002/1000/12290 2.0 ITU-T K.100 2017-07-29 5 11.1002/1000/13278 Keywords Compliance, exposure assessment, new base station, service. _ * To access the Recommendation, type the URL http:

5、/handle.itu.int/ in the address field of your web browser, followed by the Recommendations unique ID. For example, http:/handle.itu.int/11.1002/1000/11830-en. ii Rec. ITU-T K.100 (07/2017) FOREWORD The International Telecommunication Union (ITU) is the United Nations specialized agency in the field

6、of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing

7、 telecommunications on a worldwide basis. The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics. The approval of ITU-T Recommendations is covered by

8、 the procedure laid down in WTSA Resolution 1. In some areas of information technology which fall within ITU-Ts purview, the necessary standards are prepared on a collaborative basis with ISO and IEC. NOTE In this Recommendation, the expression “Administration“ is used for conciseness to indicate bo

9、th a telecommunication administration and a recognized operating agency. Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when

10、 all of these mandatory provisions are met. The words “shall“ or some other obligatory language such as “must“ and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party. INTELLECTUAL PROPERTY

11、 RIGHTSITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by

12、 ITU members or others outside of the Recommendation development process. As of the date of approval of this Recommendation, ITU had received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this m

13、ay not represent the latest information and are therefore strongly urged to consult the TSB patent database at http:/www.itu.int/ITU-T/ipr/. ITU 2017 All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU. Rec. ITU-T K

14、.100 (07/2017) iii Table of Contents Page 1 Scope . 1 2 References . 1 3 Definitions 2 3.1 Terms defined elsewhere 2 3.2 Terms defined in this Recommendation . 2 4 Abbreviations and acronyms 3 5 Assessment procedure 4 6 Equipment under test data collection 5 7 Simplified assessment procedures 6 8 Me

15、asurement area selection 9 9 Measurement . 11 9.1 Measurement equipment 11 9.2 Measured quantity 12 9.3 General exposure assessment . 12 9.4 Comprehensive exposure assessment . 13 9.5 Exposure contribution of ambient sources . 14 9.6 Determination of the total exposure ratio . 15 10 Uncertainty . 15

16、 Appendix I Radio frequency field strength measurement equipment requirements . 18 Appendix II Guidance on comprehensive measurements for specific technologies 19 II.1 Time division multiple access/frequency division multiple access technology 19 II.2 Code division multiple access/wideband code divi

17、sion multiple access technology 19 II.3 ODFM technology 20 Appendix III Maximum exposure location for a base station in the line of sight . 22 Appendix IV Exposure limits . 23 IV.1 Introduction 23 IV.2 General description of exposure limits . 23 IV.3 b-ICNIRP exposure limits . 23 Appendix V Averagin

18、g time reduction . 26 V.1 Introduction 26 V.2 Rationale and methodology 26 V.3 Results and discussion 26 Bibliography. 28 Rec. ITU-T K.100 (07/2017) 1 Recommendation ITU-T K.100 Measurement of radio frequency electromagnetic fields to determine compliance with human exposure limits when a base stati

19、on is put into service 1 Scope This Recommendation specifies the measurement procedure to assess compliance with general public electromagnetic field (EMF) exposure limits for a base station (BS) operating in the frequency range 100 MHz-40 GHz when it is put into service in its operational environme

20、nt. Simplified assessment procedures are provided to identify those installations that are known to be compliant with EMF exposure limits without measurements. With its specific focus on measurements, this Recommendation complements the existing ITU-T K-series Recommendations. Contact currents due t

21、o contact with conductive objects irradiated by EMFs, lie outside the scope of this Recommendation. For commercial market BS products, there could be other requirements specified by the manufacturer that might need to be fulfilled. For such types of product testing, this Recommendation also does not

22、 apply. Where national laws, standards or guidelines on exposure limits to EMF exist and provide procedures that are at variance with this Recommendation, the pertinent national laws, standards or guidelines shall take precedence over the procedures provided in this Recommendation. 2 References The

23、following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this

24、Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does

25、 not give it, as a stand-alone document, the status of a Recommendation. ITU-T K.52 Recommendation ITU-T K.52 (2016), Guidance on complying with limits for human exposure to electromagnetic fields. ITU-T K.61 Recommendation ITU-T K.61 (2008), Guidance on measurement and numerical prediction of elect

26、romagnetic fields for compliance with human exposure limits for telecommunication installations. ITU-T K.70 Recommendation ITU-T K.70 (2007), Mitigation techniques to limit human exposure to EMFs in the vicinity of radiocommunication stations. ITU-T K.91 Recommendation ITU-T K.91 (2017), Guidance fo

27、r assessment, evaluation and monitoring of human exposure to radio frequency electromagnetic fields. EN 50383 CENELEC EN 50383:2010, Basic standard for the calculation and measurement of electromagnetic field strength and SAR related to human exposure from radio base stations and fixed terminal stat

28、ions for wireless telecommunication systems (110 MHz-40 GHz). 2 Rec. ITU-T K.100 (07/2017) EN 50400 CENELEC EN 50400:2006, Basic standard to demonstrate the compliance of fixed equipment for radio transmission (110 MHz-40 GHz) intended for use in wireless telecommunication networks with the basic re

29、strictions or the reference levels related to general public exposure to radio frequency electromagnetic fields, when put into service. IEC 62232 IEC 62232:2017, Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base stations for the purpose of evaluatin

30、g human exposure. 3 Definitions 3.1 Terms defined elsewhere None. 3.2 Terms defined in this Recommendation This Recommendation defines the following terms: 3.2.1 ambient source: A radio frequency (RF) source operating in the frequency range from 8.3 kHz to 300 GHz generating electromagnetic fields o

31、ther than the emission from the equipment under test (EUT). 3.2.2 assessment domain boundary (ADB): Boundary surrounding an antenna of the equipment under test (EUT) outside of which measurements do not need to be conducted. The ADB defines the maximum possible measurement area where the source is c

32、onsidered to be relevant. 3.2.3 base station (BS): Fixed equipment for radio transmission used in cellular communication or wireless installation for local area networks. For the purpose of this Recommendation, the term base station includes all radio transmitter(s) and associated antenna(s). 3.2.4

33、compliance boundary (CB): Boundary defining a volume outside which the radio frequency (RF) exposure from the equipment under test (EUT) is below the exposure limit. 3.2.5 domain of investigation (DI): Sub-domain within the assessment domain boundary (ADB) to which the general public have access. 3.

34、2.6 equipment under test (EUT): The base station that shall be put into service, including all transmitting antennas (operating in the frequency range 100 MHz to 40 GHz). 3.2.7 equivalent isotropically radiated power (EIRP): The product of the power accepted by the antenna and the maximum antenna ga

35、in relative to an isotropic antenna. 3.2.8 exposure ratio (ER): The assessed exposure parameter at a specified location for each operating frequency of a radio source, expressed as the fraction of the related limit. For assessment against reference levels: ER = max (E/Elim)2, (H/Hlim)2 In the far-fi

36、eld: ER = (E/Elim)2 = (H/Hlim)2 = S/Slim where S, E, and H are the root mean square (r.m.s.) values, respectively, of power density, electric field strength and magnetic field strength measured at frequency f. Slim, Elim and Hlim are the corresponding limits at the same frequency. When exposure is e

37、valuated for a certain frequency band (the total power density or the field strength within the frequency interval fmin,fmax is assessed), Slim, Elim or Hlim are chosen as the most stringent limits within the band. Rec. ITU-T K.100 (07/2017) 3 3.2.9 far-field formula: Formula that can be used in the

38、 far-field to evaluate the power density, S: where P is the transmitted power, G, is the gain of the antenna in the direction (,) and d is the distance from the antenna to the evaluation point. The associated electric field strength, E, and magnetic field strength, H, can be evaluated as follows: wh

39、ere 0 377 . If the power density is evaluated in the direction of maximum antenna gain: 3.2.10 isotropic antenna: A hypothetical, lossless antenna having equal radiation intensity in all directions. 3.2.11 main lobe: The radiation lobe containing the direction of maximum radiation. In certain antenn

40、as, such as multilobed or split-beam antennas, there may be more than one major lobe. 3.2.12 reactive near-field region: The reactive near field of an antenna with maximum extension D is in this context defined as max(, D, D2/4) where denotes the free space wavelength. 3.2.13 relevant source: A radi

41、o source, in the frequency range 8.3 kHz to 300 GHz, which at a given point of investigation has an ER larger than 0.05. 3.2.14 side lobe: A radiation lobe in any direction other than the main lobe. 3.2.15 total exposure ratio (TER): The sum of exposure ratios (ERs) of the equipment under test (EUT)

42、 and other relevant sources. 4 Abbreviations and acronyms This Recommendation uses the following abbreviations and acronyms: ADB Assessment Domain Boundary AMPS Advanced Mobile Phone System BCCH Broadcast Control Channel BS Base Station CB Compliance Boundary CDMA Code Division Multiple Access CPICH

43、 Common Pilot Channel DAB Digital Audio Broadcasting DI Domain of Investigation DVB-T Digital Video Broadcasting-Terrestrial EIRP Equivalent Isotropically Radiated Power 2,4 dPGS ,300, EHdPGE.4 2dEIRPS 4 Rec. ITU-T K.100 (07/2017) EMF Electromagnetic Field ER Exposure Ratio EUT Equipment Under Test

44、FDMA Frequency Division Multiple Access FM Frequency Modulation GSM Global System for Mobile Communications LOS Line Of Site LTE Long-Term Evolution MCCH Multicast Control Channel OFDM Orthogonal Frequency-Division Multiplexing PBCH Physical Broadcast Channel RBW Resolution Bandwidth RF Radio Freque

45、ncy r.m.s. root mean square SAR Specific Absorption Rate SD Standard Deviation TACS Total Access Communications System TDMA Time Division Multiple Access TER Total Exposure Ratio TETRA Terrestrial Trunked Radio TETRAPOL Terrestrial Trunked Radio for Police UMTS Universal Mobile Telecommunication Sys

46、tem WCDMA Wideband Code Division Multiple Access Wi-Fi Wireless Fidelity 5 Assessment procedure When in a BS, the equipment under test (EUT), is installed and put into service at a site, the procedure described in Figure 5-1 shall be used to assess compliance with exposure limits. In order to allow

47、for accurate and efficient assessments, different routes are possible depending on the characteristic of the EUT or on the installation type. In some specific cases, compliance with relevant exposure limits can be assessed without the necessity to conduct measurements (e.g., because of the low power

48、 transmitted, or because of the position or orientation of the transmitters or antennas with respect to areas accessible to the general public, or because simpler calculation methods can be used ITU-T K.52). Both broadband and frequency-selective equipment can be used for the assessment (see clause

49、9.1). Measurements conducted with broadband equipment, however, might lead to overly conservative results. If the exposure level in areas accessible to the general public is found to be above the limits by means of broadband measurements, then compliance should be verified with frequency-selective equipment. Otherwise, the mitigation techniques described in ITU-T K.70 shall be applied. The step-by-step procedure of Figure 5-1 is specified in clauses 6 to 10. Rec. ITU-T K.100 (07/2017)

展开阅读全文
相关资源
猜你喜欢
  • EN 61300-3-8-1997 en Fibre Optic Interconnecting Devices and Passive Components Basic Test and Measurement Procedures Part 3-8 Examinations and Measurements - Ambient Light Suscept.pdf EN 61300-3-8-1997 en Fibre Optic Interconnecting Devices and Passive Components Basic Test and Measurement Procedures Part 3-8 Examinations and Measurements - Ambient Light Suscept.pdf
  • EN 61300-3-9-1997 en Fibre Optic Interconnecting Devices and Passive Components Basic Test and Measurement Procedures Part 3-9 Examinations and Measurements - Far-End Crosstalk《光纤互.pdf EN 61300-3-9-1997 en Fibre Optic Interconnecting Devices and Passive Components Basic Test and Measurement Procedures Part 3-9 Examinations and Measurements - Far-End Crosstalk《光纤互.pdf
  • EN 61302-1995 en Electrical Insulating Materials Method to Evaluate the Resistance to Tracking and Erosion Rotating Wheel Dip Test《电气绝缘材料 评定耐起痕和耐蚀损的方法 旋转轮沉浸试验(IEC 1302-1995+勘误表 199.pdf EN 61302-1995 en Electrical Insulating Materials Method to Evaluate the Resistance to Tracking and Erosion Rotating Wheel Dip Test《电气绝缘材料 评定耐起痕和耐蚀损的方法 旋转轮沉浸试验(IEC 1302-1995+勘误表 199.pdf
  • EN 61303-1995 en Medical Electrical Equipment Radionuclide Calibrators Particular Methods for Describing Performance《医用电气设备 放射性核素效准器 性能的专门规定方法 IEC 1303-1994》.pdf EN 61303-1995 en Medical Electrical Equipment Radionuclide Calibrators Particular Methods for Describing Performance《医用电气设备 放射性核素效准器 性能的专门规定方法 IEC 1303-1994》.pdf
  • EN 61305-1-1995 en Household High-Fidelity Audio Equipment and Systems - Methods of Measuring and Specifying the Performance - Part 1 General《家用高保真音响设备和系统 性能参数检测和说明的方法 第1部分 总则(IEC .pdf EN 61305-1-1995 en Household High-Fidelity Audio Equipment and Systems - Methods of Measuring and Specifying the Performance - Part 1 General《家用高保真音响设备和系统 性能参数检测和说明的方法 第1部分 总则(IEC .pdf
  • EN 61305-2-1998 en Household High-Fidelity Audio Equipment and Systems Methods of Measuring and Specifying the Performance Part 2 FM Radio Tuners《家用高保真音响设备和系统 性能参数检测和说明的方法 第2部分 FM无.pdf EN 61305-2-1998 en Household High-Fidelity Audio Equipment and Systems Methods of Measuring and Specifying the Performance Part 2 FM Radio Tuners《家用高保真音响设备和系统 性能参数检测和说明的方法 第2部分 FM无.pdf
  • EN 61305-3-1995 en Household High-Fidelity Audio Equipment and Systems Methods of Measuring and Specifying the Performance Part 3 Amplifiers《家用高保真音响设备和系统 性能参数检测和说明的方法 第3部分 放大器(IEC .pdf EN 61305-3-1995 en Household High-Fidelity Audio Equipment and Systems Methods of Measuring and Specifying the Performance Part 3 Amplifiers《家用高保真音响设备和系统 性能参数检测和说明的方法 第3部分 放大器(IEC .pdf
  • EN 61305-5-2003 en Household high-fidelity audio equipment and systems Methods of measuring and specifying the performance Part 5 Loudspeakers《家用高保真音响设备和系统 性能参数检测和说明的方法 第5部分 扬声器 IE.pdf EN 61305-5-2003 en Household high-fidelity audio equipment and systems Methods of measuring and specifying the performance Part 5 Loudspeakers《家用高保真音响设备和系统 性能参数检测和说明的方法 第5部分 扬声器 IE.pdf
  • EN 61307-2011 en Industrial microwave heating installations - Test methods for the determination of power output《工业微波加热装置 测定功率输出的试验方法》.pdf EN 61307-2011 en Industrial microwave heating installations - Test methods for the determination of power output《工业微波加热装置 测定功率输出的试验方法》.pdf