1、INTERNATIONAL TELECOMMUNICATION UNION)45G134 - TELECOMMUNICATIONSTANDARDIZATION SECTOROF ITU-!).4%.!.#% ).4%2.!4)/.!,G0G04%,%0(/.%G0G0#)2#5)432%34/2!4)/.G0G0#/.42/,G0G00/).4)45G134G0G0RecommendationG0G0- (Extract from the “LUEG0“OOK)NOTES1 ITU-T Recommendation M.725 was published in Fascicle IV.1 of

2、 the Blue Book. This file is an extract fromthe Blue Book. While the presentation and layout of the text might be slightly different from the Blue Book version, thecontents of the file are identical to the Blue Book version and copyright conditions remain unchanged (see below).2 In this Recommendati

3、on, the expression “Administration” is used for conciseness to indicate both atelecommunication administration and a recognized operating agency. ITU 1988, 1993All rights reserved. No part of this publication may be reproduced or utilized in any form or by any means, electronic ormechanical, includi

4、ng photocopying and microfilm, without permission in writing from the ITU.Fascicle IV.1 - Rec. M.725 1Recommendation M.725Fascicle IV.1 - Rec. M.725RESTORATION CONTROL POINT1 Definition of restoration control point (RCP)The restoration control point (RCP) is an element within the general maintenance

5、 organization for theinternational telecommunication services. It initiates and coordinates service restoration activities in case of failures orplanned outages of transmission systems in accordance with plans and ad hoc arrangements agreed by the technicalservices of the Administrations concerned.S

6、ince two or more RCPs are involved in agreed restoration plans, it is practical to nominate one RCP as theOverall RCP which then initiates and controls implementation of the plan. The additional responsibilities and functionsof an Overall RCP are given in 3 below.2 Responsibilities and functionsThe

7、restoration control point (RCP) is responsible for the following set of functions:2.1 Initiating the implementation of a restoration plan and ad hoc arrangements with the other stations involvedwithin its Administrations boundaries.2.2 Monitoring the implementation of the restoration plan.2.3 Coordi

8、nating the restoration activities of the repeater stations and other stations involved within itsAdministrations boundaries.2.4 Liaising with restoration control points of other Administrations as necessary and agreeing the times of eventswith them.2.5 Exchanging information with the network managem

9、ent (implementation and control point) (seeRecommendation E.413 1) for coordination purposes as appropriate.2.6 Monitoring and coordinating the return to normal service conditions after the fault has been cleared or theplanned work has been finished.2.7 Keeping, throughout the period during which th

10、e restoration and the return to normal conditions is executed,an accurate log of events, including any circuit, channel, group, supergroup, etc., or baseband patching which takesplace.2.8 Requesting and receiving reports from other RCPs and disseminating this information within its ownAdministration

11、 as required.2.9 Reporting the events to the responsible authorities of its Administration as desired and advising the systemavailability information point about the progress of restoration.2.10 Sending a final restoration report, after the return to normal, containing all relevant data (including a

12、greedtimes) for accounting purposes to the responsible authorities within its Administration.2.11 If no restoration plan exists or, for some reason, an existing plan cannot be implemented, advising theresponsible authorities in its own Administration and suggesting suitable ad hoc arrangements in th

13、e light of theinformation available.3 Additional responsibilities of an overall RCPThe responsibilities of an overall RCP are much the same as an ordinary RCP but with additionalresponsibilities as follows:3.1 Initiating the implementation of a restoration plan with other RCPs concerned.3.2 Requesti

14、ng and receiving reports from other RCPs and disseminating this information as necessary.3.3 Coordinating and controlling all restoration activities including the return to normal conditions.2 Fascicle IV.1 - Rec. M.7254 FacilitiesThe restoration control point should be provided with the following f

15、acilities:4.1 Appropriate communication facilities in order to assume its responsibilities.4.2 Access to information appropriate to its functions and this includes:a) status of relevant international transmission systems;b) current restoration plans;c) list of the sections of border-crossing transmi

16、ssion traffic routes;d) routing information for international group, supergroup, etc., links;e) inventory of spare transmission facilities, in its own and neighbouring countries, lending themselves torestoration.Reference1 CCITT Recommendation International network management - Planning, Vol. II, Rec. E.413.

展开阅读全文
相关资源
猜你喜欢
  • BS EN ISO 18542-2-2014 Road vehicles Standardized repair and maintenance information (RMI) terminology Standardized process implementation requirements Registration Authority《道路车辆 .pdf BS EN ISO 18542-2-2014 Road vehicles Standardized repair and maintenance information (RMI) terminology Standardized process implementation requirements Registration Authority《道路车辆 .pdf
  • BS EN ISO 18556-2016 Dentistry Intraoral spatulas《牙科 口腔内压舌板》.pdf BS EN ISO 18556-2016 Dentistry Intraoral spatulas《牙科 口腔内压舌板》.pdf
  • BS EN ISO 18563-1-2015 Non-destructive testing Characterization and verification of ultrasonic phased array equipment Instruments《无损试验 超声相控阵设备的特征和验证 仪器》.pdf BS EN ISO 18563-1-2015 Non-destructive testing Characterization and verification of ultrasonic phased array equipment Instruments《无损试验 超声相控阵设备的特征和验证 仪器》.pdf
  • BS EN ISO 18563-2-2017 Non-destructive testing Characterization and verification of ultrasonic phased array equipment Probes《无损检测 超声相控阵设备的鉴定和验证 探头》.pdf BS EN ISO 18563-2-2017 Non-destructive testing Characterization and verification of ultrasonic phased array equipment Probes《无损检测 超声相控阵设备的鉴定和验证 探头》.pdf
  • BS EN ISO 18592-2009 Resistance welding - Destructive testing of welds - Method for the fatigue testing of multispot- welded specimens《电阻焊接 焊接破坏性试验 多点疲劳试验方法 焊接样本》.pdf BS EN ISO 18592-2009 Resistance welding - Destructive testing of welds - Method for the fatigue testing of multispot- welded specimens《电阻焊接 焊接破坏性试验 多点疲劳试验方法 焊接样本》.pdf
  • BS EN ISO 18594-2007 Resistance spot- projection- and seam-welding - Method for determining the transition resistance on aluminium and steel material《电阻点焊、凸焊和缝隙焊接 测定铝和钢材料跃迁电阻的方法》.pdf BS EN ISO 18594-2007 Resistance spot- projection- and seam-welding - Method for determining the transition resistance on aluminium and steel material《电阻点焊、凸焊和缝隙焊接 测定铝和钢材料跃迁电阻的方法》.pdf
  • BS EN ISO 18595-2007 Resistance welding - Spot welding of aluminium and aluminium alloys - Weldability welding and testing《电阻焊接 铝和铝合金的点焊 可焊性、焊接和测试》.pdf BS EN ISO 18595-2007 Resistance welding - Spot welding of aluminium and aluminium alloys - Weldability welding and testing《电阻焊接 铝和铝合金的点焊 可焊性、焊接和测试》.pdf
  • BS EN ISO 18609-2001 Animal and vegetable fats and oils Determination of unsaponifiable matter Method using hexane extraction《动植物油脂 非皂化物测定 己烷提取法》.pdf BS EN ISO 18609-2001 Animal and vegetable fats and oils Determination of unsaponifiable matter Method using hexane extraction《动植物油脂 非皂化物测定 己烷提取法》.pdf
  • BS EN ISO 18613-2014 Pallets for materials handling Repair of flat wooden pallets《材料搬运用托盘 木制平托盘的修理》.pdf BS EN ISO 18613-2014 Pallets for materials handling Repair of flat wooden pallets《材料搬运用托盘 木制平托盘的修理》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1