KS C IEC 61948-2-2007 Nuclear medicine instrumentation-Routine tests-Part 2:Scintillation cameras and single photon emission computed tomography imaging《核医疗设备 常规试验 第2部分 闪烁照相机与单光子发射.pdf

上传人:周芸 文档编号:816832 上传时间:2019-02-12 格式:PDF 页数:14 大小:467.54KB
下载 相关 举报
KS C IEC 61948-2-2007 Nuclear medicine instrumentation-Routine tests-Part 2:Scintillation cameras and single photon emission computed tomography imaging《核医疗设备 常规试验 第2部分 闪烁照相机与单光子发射.pdf_第1页
第1页 / 共14页
KS C IEC 61948-2-2007 Nuclear medicine instrumentation-Routine tests-Part 2:Scintillation cameras and single photon emission computed tomography imaging《核医疗设备 常规试验 第2部分 闪烁照相机与单光子发射.pdf_第2页
第2页 / 共14页
KS C IEC 61948-2-2007 Nuclear medicine instrumentation-Routine tests-Part 2:Scintillation cameras and single photon emission computed tomography imaging《核医疗设备 常规试验 第2部分 闪烁照相机与单光子发射.pdf_第3页
第3页 / 共14页
KS C IEC 61948-2-2007 Nuclear medicine instrumentation-Routine tests-Part 2:Scintillation cameras and single photon emission computed tomography imaging《核医疗设备 常规试验 第2部分 闪烁照相机与单光子发射.pdf_第4页
第4页 / 共14页
KS C IEC 61948-2-2007 Nuclear medicine instrumentation-Routine tests-Part 2:Scintillation cameras and single photon emission computed tomography imaging《核医疗设备 常规试验 第2部分 闪烁照相机与单光子发射.pdf_第5页
第5页 / 共14页
点击查看更多>>
资源描述

1、 KSKSKSKSKSKSKSK KSKSKS KSKSK KSKS KSK KS KS C IEC 61948 2 2: KS C IEC 61948 2: 2007(2012 ) 2007 11 29 http:/www.kats.go.krKS C IEC 61948 2: 2007 : ( ) ( ) ( ) : (http:/www.standard.go.kr) : :2007 11 29 :2012 12 20 2012-0725 : : ( 02-509-7294) (http:/www.kats.go.kr). 10 5 , . KS C IEC 61948 2: 2007

2、(2012 ) 2: Nuclear medicine instrumentation Routine tests Part 2: Scintillation cameras and single photon emission computed tomography imaging 2001 1 IEC/TR 61948 2, Nuclear medicine instrumentation Routine tests Part 2: Scintillation cameras and single photon emission computed tomography imaging ,

3、. 1 2 ( ) ( ) (parallel hole collimators) , KS C IEC 60789 KS C IEC 61675 2 . 2 . . ( ) . KS A 4920: 2001, KS C IEC 60789: 2007, KS C IEC 61675 2: 2007, 2: KS C IEC 61675 3: 2007, 3: 3 KS A 4920, KS C IEC 60789, KS C IEC 61675 2 KS C IEC 61675 3 ( A ). . KS C IEC 61948 2: 2007 2 3.1 (QUALITY CONTROL

4、) . . 3.2 3.2.1 (ACCEPTANCE TEST) (買主 ) ( ) (parameter) . (reference data) . 3.2.2 (ROUTINE TEST) . 3.2.3 (REFERENCE DATA) 3.3 (DETECTOR HEAD) , 3.3.1 (DETECTOR HEAD TILT) 3.3.2 (DETECTOR FIELD OF VIEW) . . 3.4 (WHOLEBODY IMAGING DEVICE) 1 2 3.5 (SINGLE PHOTON EMISSION COMPUTED TOMOGRPHY: SPECT) 3.6

5、 KS C IEC 61948 2: 2007 3 (NON-UNIFORMITY OF RESPONSE) 3.6.1 (INTRINSIC NON-UNIFORMITY OF RESPONSE) 3.6.2 (SYSTEM NON-UNIFORMITY OF RESPONSE) 3.7 (SYSTEM SENSITIVITY) (plane source) 3.8 (IMAGE MATRIX) (Cartesian) 3.9 (OFFSET) COR (X p) from Xp 0 3.10 (SINOGRAM) 1 2 . . 3.11 (RADIONUCLIDE) . 3.12 ( )

6、 (ACTIVITY) : A . dN dt . dN dt (遷移 ) . tNAdd= (s 1) . (Bq) , 1 Bq 1 1 . (Ci) , 1 Ci 1 3.71010 . 3.13 (COLLIMATOR AXIS) KS C IEC 61948 2: 2007 4 (geometrical centre) 3.14 (MATRIX ELEMENT) (object) (volume element) (IMAGE MATRIX) 3.15 (PROJECTION) (PROJECTION BEAM) 2 3 , 1 2 (process) , (radon transf

7、orm) . 3.16 (OBJECT SLICE) . 3.17 (PROJECTION ANGLE) 3.18 (POINT SOURCE) 3 -function (source) 3.19 (SYSTEM AXIS) (gamma camera) . . . 3.20 (RADIUS OF ROTATION) 4 . , 20 000 . , ( ) . . , . KS C IEC 61948 2: 2007 5 4.1 2 4.1.1 (ENERGY WINDOW SETTING) . . , . 4.1.2 (Background) (background) (low energ

8、y window) . , (source) . 4.1.3 (Sensitivity check) 200 keV (source) . (source) . 4.1.4 (Non-uniformity) 4.1.4.1 2 (Planar devices) ( ) (point source) , . , ON( ) (source) . cm2 3 000 . KS C IEC 60789 . (KS C IEC 60789 10 000 ) cm2 20 000 . . 4.1.4.2 (SPECT devices) . SPECT (flood source) . 1 % 1 cm2

9、 . cm2 20 000 . . 4.1.5 (PIXEL SIZE) 2 (point source) X Y KS C IEC 61948 2: 2007 6 5 cm 10 cm . 2 (point source) . (source) mm/pixel (pixel size) . 512512 512512 . 99mTc 57Co . . 4.1.6 / (像 ) ( ) . . . 1 2 . 4.2 (SPECT) 4.2.1 . . . . . 4.2.2 (COR) Xp, Yp (: object slice ) . (source point) ( 1 ) Xp .

10、 (mulit-head system) 360 . Xp . 360 32 . 20 cm . 5 cm . (offset) (Z ) 3 , 2 1/3 . 10 000 , (pixel size) 4 mm . Xp ( ) Xp( ) Yp Y 50 mm ( ) . . Xp( ) . KS C IEC 61948 2: 2007 7 XAX += )sin()(p : A : : X : 1.5 mm . , 10 mm . , . 1 KS C IEC 61675 2 . 2 Xp Yp . Xp Yp 50 mm ( ) . “p” ( 1 ). 3 X 0 . . . (

11、mm) . 4 . 4.2.3 . ( ) . (: , , , , , , , ). 4.3 (Wholebody imaging) ( ) KS C IEC 61675 3 . 4.4 1 . KS C IEC 61948 2: 2007 8 1 * / 2 2 * . * . X, Y, Z ( ) , Z . Xp, Yp . 1 ( ) . Xp( ) . 1 KS C IEC 61948 2: 2007 9 A ( ) 3. 3./4. KS A 4920 rm (ACCEPTANCE TEST) 3.2.1 ( )(ACTIVITY)rm 13 18 (CENTER OF ROT

12、ATION) 4.2.2 (COLLIMATOR AXIS) 3.13 (DETECTOR FIELD OF VIEW) 3.3.2 (DETECTOR HEAD TILT) 3.3.1 (DETECTOR HEAD) 3.3 (ENERGY WINDOW SETTING)4.1.1 (IMAGE MATRIX) 3.8 (INTRINSIC NON-UNIFORMITY OF RESPONSE) 3.6.1 (MATRIX ELEMENT) 3.14 (NON-UNIFORMITY OF RESPONSE) 3.6 (OBJECT SLICE) 3.16 (OFFSET) 3.9 (PIXE

13、L SIZE) 4.1.5 (POINT SOURCE) 3.18 (PROJECTION ANGLE)3.17 (PROJECTION) 3.15 (PULSE AMPLITUDE ANALYZER WINDOW) 3.7 (QUALITY CONTROL) 3.1 (RADIONUCLIDE)3.11 (RADIUS OF ROTATION)3.20 (REFERENCE DATA 3.2.3 (ROUTINE TEST) 3.2.2 (SCINTILLATION CAMERA) 4.1.4.1 SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY(SPEC

14、T) 3.5 (SINOGRAM)3.10 (SYSTEM AXIS)3.19 (SYSTEM NON-UNIFORMITY OF RESPONSE) 3.6.2 (SYSTEM SENSITIVITY) 3.7 (WHOLEBODY IMAGING DEVICE) 3.4 2: 153787 1 145 3(16) (02)26240114 (02)26240148 http:/ KS C IEC 61948 2: 2007 KSKSKS SKSKS KSKS SKS KS SKS KSKS SKSKS KSKSKS Nuclear medicine instrumentation Routine testsPart 2:Scintillation cameras and single photon emissioncomputed tomography imaging ICS 11.040.50 Korean Agency for Technology and Standards http:/www.kats.go.kr

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1