1、 KSKSKSKSKSKSKSK KSKSKS KSKSK KSKS KSK KS KS X ISO/IEC 10373 7ID 7: KS X ISO/IEC 10373 7:2008 2008 6 30 http:/www.kats.go.krKS X ISO/IEC 10373 7:2008 : e- ( ) ( ) () () ( ) : (http:/www.standard.go.kr) : : 2002 12 23 : 2008 6 30 2008-0363 : e- : ( 02-509-7262) (http:/www.kats.go.kr). 10 5 , . KS X I
2、SO/IEC 10373 7:2008 ID 7: Identification cards Test methods Part 7: Vicinity cards 2001 1 ISO/IEC 10373 7, Identification cards Test methods Part 7: Vicinity cards . 1 KS X 6503(ISO/IEC 7810) ID . . KS X 6503 (ISO/IEC 7810) ID . 1 . 2 . . IC ( ) . KS X ISO/IEC 10373 1 . KS X ISO/IEC 15693 1 KS X ISO
3、/IEC 15693 2 . 2 . . ( ) . KS X 6503, ID (ISO/IEC 7810: 1995, Identification cards Physical characteristics, IDT) KS X ISO/IEC 15693 1, ID IC 1: ISO/IEC 15693 1: 2000, Identification cards Contactless integrated circuit(s) cards Vicinity cards Part 1: Physical characteristics KS X ISO/IEC 15693 2, I
4、D IC 2: ISO/IEC 15693 2: 2000, Identification cards Contactless integrated circuit(s) cards Vicinity cards KS X ISO/IEC 10373 7:2008 2 Part 2: Air interface and initialization KS X ISO/IEC 15693 3, ID IC 3: ISO/IEC 15693 3: 2000, Identification cards Contactless integrated circuit(s) cards Vicinity
5、cards Part 3: Anti-collision and transmission protocol KS C IEC 61000 4 2, (EMC) 4: 2: IEC 61000 4 2: 1995, Electromagnetic compatibility(EMC) Part 4: Testing and measurement techniques Section 2: Electrostatic discharge immunity test BIPM, IEC, IFCC, ISO, IUPAC, IUPAP, OIML, 1993, Guide to the Expr
6、ession of Uncertainty in Measurement (Gum) 3 , . 3.1 3.1.1 (base standard) . 3.1.2 (testably functional) IC KS(ISO 15693) KS X ISO/IEC 15693 3 1) . . 3.1.3 ID 3.2 DUT (device under test) ESD (electrostatic discharge) fc (frequency of the operating field) fs1, fs2 (frequencies of the subcarriers) Hma
7、xVCD (maximum fieldstrength of the VCD antenna field) HminVCD (minimum fieldstrength of the VCD antenna field) VCD (vicinity coupling device) VICC (vicinity card) 1) IC . . . KS X ISO/IEC 10373 7:2008 3 4 4.1 (233) (735) , 4060 % . 4.2 (pre-conditioning) ID 24 . 4.3 (default tolerance) , 5 % (: ) (:
8、 ) . 4.4 (spurious inductance) . 4.5 (total measurement uncertainty) . Gum 1933 . 5 (static electricity test) IC . (ESD, ) . 1 (ESD) VICC 0.5 mm KS X ISO/IEC 10373 7:2008 4 5.1 (apparatus) KS C IEC 61000 4 2 a) : 150 pF10 % : 330 10 % : 50 M 100 M : 0.71 ns b) : : . : 8 mm ( .) 5.2 . 2 20 ( ) . ( )
9、. 10 . KS X 6507 KS X ISO/IEC 7816 IC / , , . (3. ) . 123456711 12813914101516 17 18 19 20 2 ESD 5.3 . 6 KS X ISO/IEC 15693 2 VICC VCD . (6.1 ) VCD (6.2 ) KS X ISO/IEC 10373 7:2008 5 VICC (6.3 ) (6.4 ) . 6.1 (calibration coil) , , . 6.1.1 ID 1 KS X 6503(ISO/IEC 7810) . ISO/IEC 7810 ID-1 72mm 42mm1 (
10、turn) (connections) 3 6.1.2 0.76 mm10 % . . 6.1.3 . 5 mm 72 mm(2 %)42 mm(2 %) . 1 3 000 mm2 . 35 m PCB . 500 m20 % . 1.5 mm 1.5 mm . 2 13.56 MHz 200 nH , 0.25 . (: 1 , 14 pF) ( ) . ( , , ) 60 MHz . 3 35 pF 60 MHz . KS X 6503 ID 1 (connections) 72 mm42 mm1 (turn) KS X ISO/IEC 10373 7:2008 6 0.32 V(rm
11、s)/A/m(rms) 90 mV(peak-to-peak)/A/m(rms). 6.2 VCD VCD 150 mm VCD 2 ( a, b) . 4 . . VICC 50 P1 . 14 pF . . 4 150 mm KS X ISO/IEC 10373 6 . 6.2.1 VCD VCD 150 mm A . B . 6.2.2 100 mm70 mm . C . 6.2.3 VCD VCD , 5 100 mm . VCD . b : 150 mm . aVCD 220 P1 50 220 KS X ISO/IEC 10373 7:2008 7 5 VCD 100 mm 3 m
12、m . 6.3 VICC VICC . VCD(VICC ) Hmin Hmax . VCD VICC . VICC . 6.3.1 VCD power VICC D . 8.1.2 Hmax Hmin R1, R2 . C2 . 6.3.2 VICC E . . VICC VCD . VICC . 7.2 . . 6.3.3 VICC 100 mm 100 mm a b KS X ISO/IEC 10373 7:2008 8 VICC ID 1 KS X 6503(ISO/IEC 7810) . VICC , . 6 . 6 VICC 6.3.4 VICC VICC 0.76 mm10 %
13、. 6.3.5 VICC 4 . 77 mm2 %47 mm2 % . 35 m PCB . 500 m20 % . 13.56 MHz 3.5 H, 1 . 6.4 8 1 . . ( F). 7 VICC 7.1 KS X ISO/IEC 15693 2, 7.1 1 2 VICC 6.2 (Hmin, Hmax) VICC . 7.2 KS X 6503 ID 1 172 mmKS X ISO/IEC 10373 7:2008 9 1: 4 5 VCD . VCD RF VICC . 4 . 50 P1 . 40 dB . 2: VICC a . VCD RF . . 2 . . . .
14、 fc fs1 fc fs2 fc fs1 fc fs2 8.1 . KS X ISO/IEC 15693 3 VICC VCD . 7.3 fc fs1 fc fs2, fc fs1 fc fs2, , . 8 VCD 8.1 VCD 8.1.1 VCD . 8.1.2 VCD KS X ISO/IEC 15693 1 . VICC VCD D VICC . 8.1.2 a) Hmax 1) VICC 13.56 MHz . VICC LCR . VICC . KS X ISO/IEC 10373 7:2008 10 . 2) R2 J1 b . 3) VCD VICC . 4) R3( D
15、) DC (VDC) , L R2 Hmax 3 V . b) Hmin 1) VICC 13.56 MHz . 2) R1 J1 a . 3) VCD VICC . 4) R3 DC (VDC) , L R1 Hmin 3 V . 8.1.3 Hmin Hmax VDC . 8.2 (modulation index) 8.2.1 KS X ISO/IEC 15693 2 1 2 VCD . 8.2.2 , . 8.2.3 KS X ISO/IEC 15693 2 1, 2 , VCD . 8.3 ( ) VCD VICC . VCD VICC . E VCD . KS X ISO/IEC
16、10373 7:2008 11 A ( ) VCD A.1 (matching) VCD : mm( ) 1.8 mm( ) . 45 . PCB: 1.6 mm FR4 , 35 m A.1 VCD () A.2 VCD () 170 150170 KS X ISO/IEC 10373 7:2008 12 PCB / . arsenal research MIFARECertification Institute Faradaygasse 3 A 1030 Vienna Austria Phone: 43 50 550 6525 Fax: 43 1 799 19 55 mciarsenal.
17、ac.at A.2 (Rant, Lant) (Z=50 ) . C1, C2, C3 . C4 . 1 . 2 50 . 1030 %, 95100 % . 150 mA/m12 A/m H . 5 A/m . : C1 47 pF C2 180 pF C3 33 pF C4 227 pF Rext54.7( ) A.3 50 Z = 50 C2 C3 C4 C1 RantLantRextKS X ISO/IEC 10373 7:2008 13 B ( ) VCD (tuning) . . 1 : 50 1 % (: 50 BNC ) . . Y X Lissajous . . : : 13
18、.56 MHz : 25 V(rms) 50 1 % (: 50 BNC ) . Cprobe . Ccal Ccal=Cprobe . Lissajous . B.1 (1) . 50 50 : 50 : Phi = 0Ri= 50 13.56 MHz 100 Ccal= CprobeCprobeX YKS X ISO/IEC 10373 7:2008 14 2 : 1 2 . C4 0 . B.2 (2) 50 C4 : 50 : Phi = 0 Ri= 50 13.56 MHz 100 Ccal= CprobeCprobe X Y KS X ISO/IEC 10373 7:2008 15
19、 C ( ) C.1 : mm( ) 0.5 mm 20 %( ) . . PCB: 1. 6mm FR4 , 35 m C.1 a, b PCB / . arsenal research MIFARECertification Institute Faradaygasse 3 A 1030 Vienna Austria Phone: 43 50 550 6525 Fax: 43 1 799 19 55 mciarsenal.ac.at 170 170 100 R = 1070 KS X ISO/IEC 10373 7:2008 16 C.2 C.2 VCD 13.56 MHz b a KS X ISO/IEC 10373 7:2008 17 D ( ) VCD VICC C1: 5 pF : J1 a: b: : L ( ) 6.3.5 C1 5 pF C2 210 pF C3 27 pF C4 10 nF D1, D2, D3, D4 D.1 (BAR 43 ) R1 11 k R2 91 R3 100 k D.1 VICC D.1 D1, D2, D3, D4 (Tj = 25 ) Typ. VFIF=