1、*USACE / NAVFAC / AFCESA / NASA UFGS-32 31 13 (August 2010)-Preparing Activity: NASA SupersedingUFGS-32 31 13 (May 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2010*SECTION TABLE OF CONTENTSDIVISION 32 - EXTERIOR IMPROVEMENTSSECTION 32 31 13CHAIN LINK
2、FENCES AND GATES08/10PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 ASSEMBLY AND INSTALLATION INSTRUCTIONS1.4 DELIVERY, STORAGE, AND HANDLING1.5 QUALITY ASSURANCE1.5.1 Required Report Data1.5.2 Certificates of CompliancePART 2 PRODUCTS2.1 GENERAL2.2 ZINC COATING2.3 FABRIC2.4 TOP AND BOTTOM SELVAGES2.
3、5 POSTS , TOP RAILS , BOTTOM RAILS AND BRACES2.5.1 Composite Posts2.6 LINE POSTS2.7 END, CORNER, AND PULL POSTS2.8 SLEEVES2.9 TOP RAIL2.10 CENTER RAILS BETWEEN LINE POSTS2.11 BOTTOM RAIL2.12 POST-BRACE ASSEMBLY2.13 TENSION WIRE2.14 STRETCHER BARS2.15 POST TOPS2.16 STRETCHER BAR BANDS2.17 GATE POSTS2
4、.18 GATES2.19 GATE HARDWARE AND ACCESSORIES2.20 MISCELLANEOUS HARDWARE2.21 WIRE TIES2.22 CONCRETE2.23 GROUTSECTION 32 31 13 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.24 PADLOCKSPART 3 EXECUTION3.1 GENERAL3.2 EXCAVATION3.3 SETTING POSTS3
5、.3.1 Earth and Bedrock3.3.2 Concrete Slabs and Walls3.3.3 Bracing3.4 CONCRETE STRENGTH3.5 TOP RAILS3.6 CENTER RAILS3.7 BRACE ASSEMBLY3.8 TENSION WIRE INSTALLATION3.9 FABRIC INSTALLATION3.10 STRETCHER BAR INSTALLATION3.11 GATE INSTALLATION3.12 TIE WIRES3.13 FASTENERS3.14 ZINC-COATING REPAIR3.15 TOLER
6、ANCES3.16 SITE PREPARATION3.16.1 Clearing and Grading3.17 FENCE INSTALLATION3.17.1 Post Spacing3.17.2 Top and Bottom Tension Wire3.18 ACCESSORIES INSTALLATION3.18.1 Post Caps3.18.2 Padlocks3.19 GROUNDING3.20 SECURITY3.21 CLEANUP- End of Section Table of Contents -SECTION 32 31 13 Page 2Provided by I
7、HSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-32 31 13 (August 2010)-Preparing Activity: NASA SupersedingUFGS-32 31 13 (May 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2010*SE
8、CTION 32 31 13CHAIN LINK FENCES AND GATES08/10*NOTE: This guide specification covers the requirements for steel fencing, including posts, fabric, gates, and miscellaneous accessories. Colored fabric and accessories may be used if required. Edit specifications to suit the project scope.Use Section 32
9、 31 13.53 HIGH-SECURITY CHAIN LINK FENCES AND GATES.Use Section 32 31 26 WIRE FENCES AND GATES formerly referred to as “Farm Style Fencing“ within UFGS.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable item(s
10、) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of techni
11、cal proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide sp
12、ecification. The publications are referred to in the text by basic designation only and listed in SECTION 32 31 13 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-this paragraph by organization, designation, date, and title.Use the Reference Wi
13、zards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted fro
14、m this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.ASTM INTERNATIONA
15、L (ASTM)ASTM A 116 (2005) Standard Specification for Metallic-Coated, Steel Woven Wire Fence FabricASTM A 153/A 153M (2009) Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel HardwareASTM A 702 (1989; R 2006) Standard Specification for Steel Fence Posts and Assemblies, Hot WroughtAS
16、TM A 780/A 780M (2009) Standard Practice for Repair of Damaged and Uncoated Areas of Hot-Dip Galvanized CoatingsASTM A 90/A 90M (2009) Standard Test Method for Weight Mass of Coating on Iron and Steel Articles with Zinc or Zinc-Alloy CoatingsASTM B 117 (2009) Standing Practice for Operating Salt Spr
17、ay (Fog) ApparatusASTM C 94/C 94M (2009a) Standard Specification for Ready-Mixed ConcreteASTM F 1043 (2008) Strength and Protective Coatings on Metal Industrial Chain-Link Fence FrameworkASTM F 1083 (2008) Standard Specification for Pipe, Steel, Hot-Dipped Zinc Coated (Galvanized) Welded, for Fence
18、StructuresASTM F 567 (2007) Standard Practice for Installation of Chain Link FenceASTM F 626 (2008) Standard Specification for Fence SECTION 32 31 13 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-FittingsASTM F 883 (2009) PadlocksASTM G 152 (
19、2006) Operating Open Flame Carbon Arc Light Apparatus for Exposure of Nonmetallic MaterialsASTM G 153 (2004) Operating Enclosed Carbon Arc Light Apparatus for Exposure of Nonmetallic MaterialsASTM G 154 (2006) Standard Practice for Operating Fluorescent Light Apparatus for UV Exposure of Nonmetallic
20、 MaterialsASTM G 155 (2005a) Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic MaterialsU.S. GENERAL SERVICES ADMINISTRATION (GSA)FS RR-F-191 (Rev K) Fencing, Wire and Post Metal (and Gates, Chain-Link Fence Fabric, and Accessories)FS RR-F-191/1 (Rev D) Fencing,
21、Wire and Post, Metal (Chain-Link Fence Fabric)FS RR-F-191/2 (Rev D) Fencing, Wire and Post, Metal (Chain-Link Fence Gates)FS RR-F-191/3 (Rev D) Fencing, Wire and Post, Metal (Chain-Link Fence Posts, Top Rails and Braces)FS RR-F-191/4 (Rev D) Fencing, Wire and Post, Metal (Chain-Link Fence Accessorie
22、s)1.2 SUBMITTALS*NOTE: Review Submittal Description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submitta
23、l item indicates that the submittal requires Government approval. Some submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently import
24、ant or complex in context of the project.For submittals requiring Government approval on Army projects, a code of up to three characters within SECTION 32 31 13 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-the submittal tags may be used foll
25、owing the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Of
26、fice; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed item for Army projects.*Government approval is required for submittals with a
27、 “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control approval.for information only. When used, a designation following the “G“ designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section
28、01 33 00 SUBMITTAL PROCEDURES:SD-02 Shop DrawingsFence Assembly; G; G, _Location of Gate, Corner, End, and Pull Posts; G; G, _Gate Assembly; G; G, _Gate Hardware and Accessories; G; G, _Erection/Installation Drawings; G; G, _SD-03 Product DataFence Assembly; G; G, _Gate Assembly; G; G, _Gate Hardwar
29、e and Accessories; G; G, _Recycled Material Content; G; G, _Zinc Coating; G; G, _PVC Coating; G; G, _Aluminum Alloy Coating; G; G, _Fabric; G; G, _Stretcher Bars; G; G, _Concrete; G; G, _SD-04 SamplesSECTION 32 31 13 Page 6Provided by IHSNot for ResaleNo reproduction or networking permitted without
30、license from IHS-,-,-Fabric; G; G, _Posts; G; G, _Braces; G; G, _Line Posts; G; G, _Sleeves; G; G, _Top Rail; G; G, _Bottom Rail; G; G, _Tension Wire; G; G, _Stretcher Bars; G; G, _Gate Posts; G; G, _Gate Hardware and Accessories; G; G, _Padlocks; G; G, _Wire Ties; G; G, _SD-07 CertificatesCertifica
31、tes of Compliance; G; G, _SD-08 Manufacturers InstructionsFence Assembly; G; G, _Gate Assembly; G; G, _Hardware Assembly; G; G, _Accessories; G; G, _1.3 ASSEMBLY AND INSTALLATION INSTRUCTIONSSubmit manufacturers erection/installation drawings and instructions that detail proper assembly and material
32、s in the design for fence, gate, hardware and accessories.Submit erection/installation drawings along with manufacturers catalog data for complete fence assembly, gate assembly, hardware assembly and accessories.1.4 DELIVERY, STORAGE, AND HANDLINGDeliver materials to site in an undamaged condition.
33、Store materials off the ground to provide protection against oxidation caused by ground contact.SECTION 32 31 13 Page 7Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1.5 QUALITY ASSURANCE1.5.1 Required Report DataSubmit reports of listing of chain-l
34、ink fencing and accessories regarding weight in grams ounces for zinc coating, thickness of PVC coating, and chemical composition and thickness of aluminum alloy coating.1.5.2 Certificates of ComplianceSubmit certificates of compliance in accordance with the applicable reference standards and descri
35、ptions of this section for the following:a. Zinc coatingb. PVC coatingc. Aluminum alloy coatingd. Fabrice. Stretcher barsf. Gate hardware and accessoriesg. ConcretePART 2 PRODUCTS2.1 GENERALProvide fencing materials conforming to the requirements of ASTM A 116, ASTM A 702, ASTM F 626, and as specifi
36、ed.Submit manufacturers data indicating percentage of recycled material content in protective fence materials, including chain link fence, fabric, and gates to verify affirmative procurement compliance.2.2 ZINC COATINGProvide hot-dip galvanized (after fabrication) ferrous-metal components and access
37、ories, except as otherwise specified.Provide zinc coating of weight not less than 550 gram per square meter 1.94 ounces per square foot, as determined from the average result of two specimens, when tested in accordance with ASTM A 90/A 90M.Provide zinc coating conforming to the requirements of the f
38、ollowing:a. Pipe: FS RR-F-191/3 Class 1 Grade A in accordance with ASTM F 1083 Grade B in accordance with ASTM F 1043.b. Hardware and accessories: ASTM A 153/A 153M, Table 1c. Surface: ASTM F 1043d. External: Type B-B surface zinc with organic coating, 275 gram per square meter 0.97 ounce per square
39、 foot minimum thickness of acrylated polymer.SECTION 32 31 13 Page 8Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-e. Internal: Surface zinc coating of 275 gram per square meter 0.97 ounce per square foot minimum.Provide galvanizing repair material
40、that is cold-applied zinc-rich coating conforming to ASTM A 780/A 780M.2.3 FABRIC*NOTE: Coordinate type of fabric with project requirements. The four types of fabric are not necessarily equivalent. Certain security applications may require use of steel fabric only. Standard selvage treatment for fab
41、ric 1.52 m 60 inches and less is knuckled at both selvages. Fabric with heavier zinc or aluminum coating or polyvinyl chloride (PVC) coatings may be useful in highly corrosive environments.*NOTE: Choose core wire gage appropriate for the design. Gages are not be the same for all materials. Polyvinyl
42、 chloride (PVC) coating may be specified for other than security purposes when aesthetics are of prime importance and the additional cost is justified. There are different PVC-coated fabrics on the market. Variations may include: The methods of applying PVC coating, wall thickness of PVC coating, ad
43、hesion of PVC coating to wire, and cost. Take these factors into consideration when selecting a fence fabric for different environmental applications. PVC coating of fencing for certain security applications and grounded fencing requires detailed design and specifying.*FS RR-F-191 and detailed specifications as referenced and other requirements as specified.FS RR-F-191/1; Type I, zinc-coated steel, _ gage II, aluminum-coated steel, _ gage III, aluminum alloy, _ gage or IV, polyvinyl chloride (PVC) coated over zinc- or aluminum-coated steel, _-gage core wire size. Mesh size, 51 m