1、This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2015 by Navistar, Inc. JUNE 2015 Page 1 of 2 NAVISTAR, INC. Material, Parts, and Process Specifications (

2、MPAPS) NUMBER: MPAPS S-D-200.102-GS/PL Former Designation: ESP-D-200.102-GS TITLE: Wobble Gage and Gaging for Cross Recess Tapping and Wood Screws - English Series (Noun Code 7450) CURRENT REV No.: 1506 DATE: June 2015 WRITTEN/EDITED BY: Materials Engineering APPROVED BY: Materials Engineering SUPER

3、SEDES: ESP-D-200.102-GS - September 2000 PRINTED COPIES OF THIS DOCUMENT MUST BE VERIFIED FOR CURRENT REVISION This specification may involve hazardous materials, equipment, and procedures. This specification does not purport to address all of the safety issues associated with its use. The user is r

4、esponsible to consult appropriate safety and health practices and to determine the applicability of regulatory limits prior to use. Change Notice: Changed to New MPAPS format. 1.0 GENERAL: Wobble gaging provides a means for determining the compatibility of cross recesses in the heads of screws with

5、companion screw drivers and will indicate the point where deviations in the recess contours affects satisfactory driver engagement. Recesses which exhibit excessive wobble characteristics will result in poor screw driveability because of driver camout prior to attaining normal torque level; damage t

6、o recesses; and/or accelerated driver wear. The allowable total wobble gaging limits tabulated herein were predicated originally on the gaging of plain finish (unplated or uncoated) screws. However, subsequent experience has shown these limits to be suitable for gaging of screws having coating thick

7、ness up to and including .0003 inch on significant surfaces. Screws having heavier coatings, which fail to meet the wobble gaging requirements, will be stripped of finish and gaged for acceptance or rejection in the plain condition. Wobble gaging fixtures such as illustrated above and appropriate cr

8、oss recess master plug gages with handles and position indicators are available through screw manufacturers. Dimensions of NUMBER: MPAPS S-D-200.102-GS/PL TITLE: Wobble Gage and Gaging for Cross Recess Tapping and Wood Screws REVISION: 1506 This document is restricted and may not be sent outside Nav

9、istar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2015 by Navistar, Inc. JUNE 2015 Page 2 of 2 points on master plug gages are, except for the diameters, tabulated herein, the same as those specified for respective

10、 penetration gage points on preceding page. The screw to be gaged will be placed into screw holding chuck and oriented such that one set of recess wings is parallel to the upright back plate. The screw will be so positioned and the chuck will be tightened sufficiently to prevent any tilting of the s

11、crew in the chuck when taking wobble readings. The position gage pointer and handle with the proper master plug gage for the recess size being checked will be positioned in the slot in the degree scale on top plate and the point of the gage inserted into the screw recess. It is essential that regist

12、ry between the cross lines of pointer and the recess wings be maintained. To correct any misalignment, the chuck position lock screw is loosened, the chuck is rotated until registry is obtained, and the chuck is raised or lowered until the gage pointer is flush with the top of the degree scale. The

13、chuck position lock screw is then tightened and the readings taken. The gage handle, with downward pressure applied, is moved from side to side until resistance is encountered and the total reading between points of travel of the gage pointer is recorded. The allowable angular wobble limits will not

14、 exceed the values as tabulated. Cross lines on gage pointer should be rechecked with plug gage wings to make certain cross lines and gage wings are registered on identical radials. Recess Size Number Gage Body Diameter, B Maximum Allowable Total Wobble Type 1 Type 1A Max Min in mm 0 .135 .115 * 1 .

15、198 .178 15 12 2 .260 .240 12 10 3 .323 .303 10 8 4 .385 .365 10 8 * Value not currently available. 2.0 RESTRICTED CHEMICAL SUBSTANCES: Effective January 1, 2007, all product supplied to the requirements of this specification must comply with the requirements of the MPAPS B-50 specification. 3.0 TEC

16、HNICAL INFORMATION: For further information related to the technical content of this specification, contact: Suppliers may purchase controlled copies of this specification by contacting: Materials Engineering and Technology Dept. 10400 W. North Avenue Melrose Park, IL 60160 E-mail: MaterialsEngineeringN IHS Global Inc. 15 Inverness Way East Englewood CO 80112-5776 Phone: 1-800-854-7179 E-mail: AutomotiveIHS.com Website: http:/

展开阅读全文
相关资源
猜你喜欢
  • ITU-T V 8 FRENCH-2000 Procedures for starting sessions of data transmission over the public switched telephone network《公共交换电话网中开始数据传输对话的规程 V系列 电话网数据通讯 通用 16号研究组》.pdf ITU-T V 8 FRENCH-2000 Procedures for starting sessions of data transmission over the public switched telephone network《公共交换电话网中开始数据传输对话的规程 V系列 电话网数据通讯 通用 16号研究组》.pdf
  • ITU-T V 8 SPANISH-2000 Procedures for starting sessions of data transmission over the public switched telephone network《公共交换电话网中开始数据传输对话的规程 V系列 电话网数据通讯 通用 16号研究组》.pdf ITU-T V 8 SPANISH-2000 Procedures for starting sessions of data transmission over the public switched telephone network《公共交换电话网中开始数据传输对话的规程 V系列 电话网数据通讯 通用 16号研究组》.pdf
  • ITU-T V 8-2000 Procedures for Starting Sessions of Data Transmission over the Public Switched Telephone Network - Series V Data Communication over the Telephone Network - General (.pdf ITU-T V 8-2000 Procedures for Starting Sessions of Data Transmission over the Public Switched Telephone Network - Series V Data Communication over the Telephone Network - General (.pdf
  • ITU-T V 80 AMD 1 FRENCH-2001 In-band DCE control and synchronous data modes for asynchronous DTE Amendment 1《在波段的数据通信设备控制和同步数据模式的数据终端设备 系列V 数据交流和电话网络 数据和其他信号的同时传输 修改件1 (研究组16.pdf ITU-T V 80 AMD 1 FRENCH-2001 In-band DCE control and synchronous data modes for asynchronous DTE Amendment 1《在波段的数据通信设备控制和同步数据模式的数据终端设备 系列V 数据交流和电话网络 数据和其他信号的同时传输 修改件1 (研究组16.pdf
  • ITU-T V 80 AMD 1 SPANISH-2001 In-band DCE control and synchronous data modes for asynchronous DTE Amendment 1《在波段的数据通信设备控制和同步数据模式的数据终端设备 系列V 数据交流和电话网络 数据和其他信号的同时传输 修改件1 (研究组1.pdf ITU-T V 80 AMD 1 SPANISH-2001 In-band DCE control and synchronous data modes for asynchronous DTE Amendment 1《在波段的数据通信设备控制和同步数据模式的数据终端设备 系列V 数据交流和电话网络 数据和其他信号的同时传输 修改件1 (研究组1.pdf
  • ITU-T V 80 AMD 1-2001 In-Band DCE Control and Synchronous Data Modes for Asynchronous DTE - Series V Data Communication over the Telephone Network Simultaneous Transmission of Data6).pdf ITU-T V 80 AMD 1-2001 In-Band DCE Control and Synchronous Data Modes for Asynchronous DTE - Series V Data Communication over the Telephone Network Simultaneous Transmission of Data6).pdf
  • ITU-T V 80 FRENCH-1996 IN-BAND DCE CONTROL AND SYNCHRONOUS DATA MODES FOR ASYNCHRONOUS DTE《异步数据终端设备(DTE)的带内数据通信设备(DCE)控制和同步数据模式 V系列 电话网数据传输 接口和音频宽带调制解调器 14号研究组 38pp》.pdf ITU-T V 80 FRENCH-1996 IN-BAND DCE CONTROL AND SYNCHRONOUS DATA MODES FOR ASYNCHRONOUS DTE《异步数据终端设备(DTE)的带内数据通信设备(DCE)控制和同步数据模式 V系列 电话网数据传输 接口和音频宽带调制解调器 14号研究组 38pp》.pdf
  • ITU-T V 80 SPANISH-1996 IN-BAND DCE CONTROL AND SYNCHRONOUS DATA MODES FOR ASYNCHRONOUS DTE《异步数据终端设备(DTE)的带内数据通信设备(DCE)控制和同步数据模式 V系列 电话网数据传输 接口和音频宽带调制解调器 14号研究组 38pp》.pdf ITU-T V 80 SPANISH-1996 IN-BAND DCE CONTROL AND SYNCHRONOUS DATA MODES FOR ASYNCHRONOUS DTE《异步数据终端设备(DTE)的带内数据通信设备(DCE)控制和同步数据模式 V系列 电话网数据传输 接口和音频宽带调制解调器 14号研究组 38pp》.pdf
  • ITU-T V 80-1996 In-Band DCE Control and Synchronous Data Modes for Asynchronous DTE - Series V Data Communication over the Telephone Network Interfaces and Voiceband Modems (Study .pdf ITU-T V 80-1996 In-Band DCE Control and Synchronous Data Modes for Asynchronous DTE - Series V Data Communication over the Telephone Network Interfaces and Voiceband Modems (Study .pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1