1、A-A-18 56A August 20, i984 SUPERSEDING A-A-1856 June 12, i981 COMMERCIAL ITEM DESCRIPTION LAMP, FLUORSCENT (F40CW Energy Saving) The General Services Administration has authorized the use of this commercial item description in preference to -Federal Specification W-L00116D/GEN and W-L-O0116/48. This
2、 commercial item description covers 35 watt, rapid-start type, energy saving fluorescent lamps. Salient characteristics. Bulb - T-12 Nominal length - 48 inches Base - Medium bipin Average rated life - 3 hours per start - 20,000 hours Initial lumens (after 100 hours burning) - 2700 lumens Lumens at 4
3、0 percent of life - 2250 lumens Color - Cool white when tested in accordance with ANSI C78.376 Designed to operate on one- or two-lamp 40 watt, lead-circuit, high power requirements, and in ambient temperature of not less than 18 degrees C -factor, rapid-start indoor ballasts that meet ANSI c82 and
4、UL Standard 935 . (65 degrees .F) Dimensional characteristics shall be in accordance with ANSI (278.1. The issues of ANSI c78.1, ANSI C78.376, ANSI C82, and UL Standard 935 in effect on the date of the solicitation shall be used to determine com- pliance with these requirements. matory requirements.
5、 The offerof/contractor is encouraged to use recovered materials in accordance with Public Law 94-580 to the maximum extent practical. Preservation, packaging, packing, labeling and marking. aging, packing, labeling, and marking shall be as specified in the contract or order. Preproduction inspectio
6、n. One package of lamps, produced using the same tooling, production, and assembly methods that are used for production lots, shall be sub- mitted for examination and test in accordance with the above requirements. umentation consisting of the certification and test data shall be presented for exami
7、nation during performance of the preproduction inspection. Failure of the preproduction samples to pass the examination of one or more of the tests, the lack of required documentation, or failure of the documentation to substantiate conformance to the requirements of this CID shall be cause for reje
8、ction. The preservation, pack- Doc- Notes. Standards Institute, i430 Broadway, New York, NY UL Standard No. 935 is available from Underwriters Laboratories, Ind., 333 Pfginsten Road, Northbrook, IL Copies of ANSI Standards are available from the American National 10018. 60062, y THIS DOCUMENT CONTAI
9、NS .-.A PAGES FSC 6240 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-1856 The commercial. item certification clause is not required when this commercial description is used for procurement. MILITARY INTERESTS : Military Coordinating Activity. None. DoD has waived coorination until further notice. CIVIL AGENCY COORDINATING ACTIVITY: -on this commercial item description COMMERCE-NBS PREPARING ACTIVITY: GSA-FES Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-