1、A-A-5 06 11 3 December 1993 COMMERCIAL ITEM DESCRIPTION BATTERY, STORAGE (PORTABLE, SEALED, MAINTENANCE-FREE, LEAD-ACID) 6 VOLT, 50 AMPERE-HOUR, TYPE 6V-S-50 AH The General Services Administration has authorized the use of this Commercial Item Description. Abstract. This Commercial Item Description
2、covers a 6 volt (normal and reversed), 50 ampere-hour sealed, valve-regulated lead-acid (VRLA), storage battery with a low rate and deep discharge duty cycle for use on Naval surface ships. Definition of Normal and Reversed. with the intercell connectors as shown, the positive terminal is located: L
3、ooking at the battery top at top right for Normal (N) at top left for Reversed (R) Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, Naval Sea Systems Command, ATTN: 03R42, 2531 Jeffers
4、on Davis Hwy, Arlington, VA 2242-5160. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-SObLL = 9999974 Olbl997 Tb8 O A-A-506 11 Salient characteristics. The product shall be a 6 volt (normal and reversed), 50 ampere-hour sealed lead-acid storage
5、battery, meeting the requirements specified below. 1. Dimensions. The maximum dimensions for the battery shall be: length - 9.1 inches width - 7.1 inches height - 9.4 inches 2. Weight. The battery weight shall be 44 pounds maximum when filled. 3. Terminals. The terminals shall be Battery Council Int
6、ernational Type V supplied with wingnuts and capable of receiving a round end lug accepting an AWG #2 cable. 4. Pressure relief valve. The battery shall have sufficient pressure relief valves to prevent rupturing of the battery when internal pressure exceed battery design pressure. 5. Capacity. a. T
7、he capacity for the 5 amp (or 10 hour) rate shall be a minimum of 50 ampere-hours with a cut-off voltage of 5.25 volts in the temperature range of 20“ to 27“ C. b. The capacity for the 16 ampere (or 2 hour) rate shall be a minimum of 32 ampere-hours with a cut-off voltage of 4.8 volts in the tempera
8、ture range of 20“ to 27“ C. 6. Reserve capacity. The battery shall deliver 25 amperes for a minimum of 60 minutes at 25C with a cut-off voltage of 5.25 volts. 7. Retention of charqe. The battery shall retain at least 80% of the 10 hour-rate capacity (50 ampere-hours) 28 days after charge termination
9、 when discharged at the 10 hour rate. 8. Cvclinq. The battery shall be capable of 270 cycles minimum. The cycles shall consist of any combination of the requirements listed in paragraphs 5 and 7 with a minimum of 80% capacity at the specified rate. At least one cycle of each capacity check listed in
10、 paragraph 5 shall be conducted for verification. Only cycles yielding 80% or greater capacity are to be counted. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-50611 9999974 0161998 9T4 A-A-506 11 Charging shall be conducted with a constant p
11、otential charger set at 7.05 volts with a limiting current of 10 amperes. 9. Bid samples. When specified in the solicitation, bid samples shall be furnished. Contractor Certification. The contractor shall certify and maintain substantiating evidence that the product offered meets the salient charact
12、eristics of this Commercial Item Description, and that the product conforms to the producers own drawings, specifications, standards and quality assurance practices. The government reserves the right to require proof of such conformance prior to first delivery and thereafter as may be otherwise prov
13、ided for under the provisions of the contract. Metric Products. Products manufactured to metric dimensions will be considered on an equal basis with those manufactured using inch-pound units, provided they fall within specified tolerances using conversion tables contained in the latest revision of F
14、ederal Standard No. 376 and all other requirements of this Commercial Item Description are met. If a product is manufactured to metric dimensions, the dimensions and tolerances shall not exceed those specified in the inch-pound units, and overall outside dimensions shall remain equal to or less than
15、 those stated in inches. The contracting officer has the option of accepting or rejecting the product. Requlatory Requirements. The offeror/contractor is encouraged to use recovered materials in accordance with Public Law 94-580 to the maximum extent practicable. Safety A Material Safety Data Sheet
16、(MSDS) is required in accordance with Code of Federal Regulations, 29 CFR 1910-1200 and FED-STD-313. Preservation, packasins, p ackinq, labelinq and markinq. The preservation, packaging, packing, labeling and marking shall be as specified in the contract or order. Notes. Purchaser should specify vol
17、tage, ampere-hours and size if bid samples are required. FED-STD-376 is available from the Standardization Documents Order Desk, 700 Robbins Avenue, Building #4, Section D, Philadelphia, PA 19111-5094. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-
18、,-A-A- 5 O 6 1 1 Potential sources. Based on information available at the time this document was developed, the following products are believed to comply with the salient characteristics of this Commercial Item Description. Competition is not limited to the indicated sources. Manufacturer Manufactur
19、ers battery code C&D Charter Power Systems Inc. LS -6-5 O 3043 Walton Road Plymouth Meeting, PA 19462 Concorde Battery Corp. 2009 San Bernadino Ave West Covina, CA 91803 Eagle-Picher Industries Inc. P.O. Box 130 North Better Road Seneca, MO 64865 RG-252 CF 6V50 (with BCI Type V terminal) MILITARY IN
20、TERESTS: CIVIL AGENCY COORDINATING ACTIVITIES Military Coordinatinq GSA - FSS Activity Navy - SH Custodian PREPARING ACTIVITY: Army - ER Air Force - 99 Navy - SH Review Army - AV, MI, AT Air Force - 11, 80 Navy - AS DLA - GS NAVY - SH PROJECT 6140-0742 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-