NAVY A-A-59184-1998 DISPENSER CARBONATED BEVERAGE MECHANICALLY REFRIGERATED (NAVAL SHIPBOARD)《海军船机械冷却碳酸饮料药剂师》.pdf

上传人:dealItalian200 文档编号:976359 上传时间:2019-03-13 格式:PDF 页数:5 大小:229.76KB
下载 相关 举报
NAVY A-A-59184-1998 DISPENSER CARBONATED BEVERAGE MECHANICALLY REFRIGERATED (NAVAL SHIPBOARD)《海军船机械冷却碳酸饮料药剂师》.pdf_第1页
第1页 / 共5页
NAVY A-A-59184-1998 DISPENSER CARBONATED BEVERAGE MECHANICALLY REFRIGERATED (NAVAL SHIPBOARD)《海军船机械冷却碳酸饮料药剂师》.pdf_第2页
第2页 / 共5页
NAVY A-A-59184-1998 DISPENSER CARBONATED BEVERAGE MECHANICALLY REFRIGERATED (NAVAL SHIPBOARD)《海军船机械冷却碳酸饮料药剂师》.pdf_第3页
第3页 / 共5页
NAVY A-A-59184-1998 DISPENSER CARBONATED BEVERAGE MECHANICALLY REFRIGERATED (NAVAL SHIPBOARD)《海军船机械冷却碳酸饮料药剂师》.pdf_第4页
第4页 / 共5页
NAVY A-A-59184-1998 DISPENSER CARBONATED BEVERAGE MECHANICALLY REFRIGERATED (NAVAL SHIPBOARD)《海军船机械冷却碳酸饮料药剂师》.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 INCH-POUND I A-A- 5 9 1% 4 27 May 199% COMMERCIAL ITEM DESCRIPTION DISPENSER, CARBONATED BEVERAGE, MECHANICALLY REFRIGERATED (NAVAL SHIPBOARD) The General Services Administration has authorized the use of this commercial item description for all federal agencies. 1. SCOPE This commercial item descr

2、iption (CID) covers mechanically refrigerated, pressurized, carbonated beverage (soft drink) dispensers for Naval shipboard use. The dispensers are for use in self-service serving lines to mix, cool, and dispense carbonated and nonpulp noncarbonated drinks. The carbonators in each unit are used in c

3、onjunction with CO2 gas cylinders, which must be procured separately. 2. CLASSIFICATION Size 1: Four dispensing heads Size 2: Five dispensing heads 3. SALIENT CHARACTERISTICS 3.1 Design and construction. The carbonated beverage dispenser shall be mechanically refrigerated, have a pressurized syrup f

4、eed system, and single- line serving. The dispenser shall be equipped with a key lock switch. The cabinet shall be provided with four 4-iBch high stainless steel legs suitable for mounting the equipment to a countertop. 3.1.1 Refrigeration unit. The refrigeration unit shall consist of a compressor,

5、an air-cooled type condenser, a pump, an ice bank or cold plate (when used), a carbonator, and electrical and plumbing connections. The refrigeration unit shall be completely self-contained, precharged, and wired with a hermetically sealed compressor unit. The unit shall be capable of maintaining a

6、continuous drink temperature, at a rate of 600 6-ounce drinks in a 90-minute period, of not greater than 42F without ice at the dispensing head when the ambient temperature is not greater than 90F. The unit shall operate at water pressures from 15 to 80 pounds per square inch gauge. Beneficial comme

7、nts, recommendations, additions, deletions, clarifications, etc., and any other data which may improve this document should be sent to: Commander, Naval Sea Systems Command, 2531 Jefferson-Davis Highway, Arlington, VA 22242-5160. AMSC N/A FSC 7310 DISTRIBUTION STATEMENT A. Approved for public releas

8、e; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59LY 9038054 0000705 526 A-A- 5 9 18 4 3.1.1.1 Refrigerant (ozone depleting substance). The refrigerant shall be in accordance with ASHM 15, Group Al (nonflanunable), b

9、e in accordance with AR1 700 (purity), and be approved by the Environmental Protection Agency under the Significant New Aiternate Program. The refrigerants permitted for use, in order of preference, shall be of one of the following: R134A, R-40.A, or R-401B. 3.1.2 Dispenser cabinet. the quality norm

10、ally used by the manufacturer in its standard commercial dispensers, provided that the completed dispenser is in accordance with the provisions of this document. The dispensing assembly shall be constructed of stainless steel. Dispensing valves shall be electrically operated and shall be equipped wi

11、th solenoids rated for continuous duty. Each valve shall be easily removable with basic hand tools without interrupting the operation of the other dispensing valves. Easily accessible connections with quick disconnect ball lock fittings shall be provided for cold water, syrup, and carbon dioxide sup

12、plies, and the fittings shall be noninterchangeable. 3.1.3 Hoses. Supply lines shall be the manufacturers standard commercial high-pressure reinforced hoses. The cabinet shall be of materials and components of I 3.1.4 Drain pan. under the dispensing valves. of tools and shall have a closeable drain

13、hole. A removable drain pan and perforated tray shall be provided The drain pan shall be removable without the use 3.1.5 Dispenser. The dispenser shall be a mechanically refrigerated, pressurized unit that dispenses carbonated beverages, noncarbonated beverages, and water. It shall dispense not less

14、 than 600 6-ounce drinks in a 90-minute period. The dispenser may be installed with syrup tanks, carbon dioxide tank, carbonator, and water supply, each remotely located not more than 50 feet from the dispenser. The dispensing heads shall be accessible from one side only. Two syrup tanks shall be pr

15、ovided for each dispenser head. Both tanks shall have the same capacity, either 3 or 5 gallons. 3.1.6 Physical size limitations. so that it can pass throuah a shipboard access measurina 26 x 66 inches with The cabinet shall pass or shall disassemble 8-inch radius corners. The refrigeration system sh

16、all not require disassembly to pass through access openings. When specified for submarines, the cabinet shall pass or shall disassemble so that it can pass through a 30 inch diameter submarine access. (Shipboard requirement, see 7.2) 3.2 Accessibility. The unit shall be physically and visually acces

17、sible from the front for operation and for normal maintenance with tools, test equipment, and replacement parts. No special tools shall be required for access or parts replacement. 3.3 Electrical requirements. The unit shall operate on 115 VAC, 60 Hz, single-phase power, as defined in MIL-STD-1399,

18、Section 300, and shall have provisions for making direct (hardwired) connections for electric power (2 conductors) and for equipment grounding (1 conductor). All outermost metallic surfaces shall be grounded via the equipment grounding connection. The grounding resistance between any exposed metalli

19、c surfaces and the common ground point shall be not greater than 0.1 ohm. Electrical components, other than the hermetically sealed motor, shall be provided in accordance with NEMA Type 13 or equivalent enclosure protection. Metal parts of electrical components and enclosures shall be inherently cor

20、rosion resistant or shall be treated and processed for corrosion resistance in accordance with IEEE Standard 45. Mercury-type float switches shall not be used. (Shipboard requirement, see 7.2) 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-593

21、B4 9038054 O000706 462 A-A-5 91 8 4 3.4 Inclined operation. The unit shall operate satisfactorily (in accordance with the requirements of this CID) with no spillage of liquid or product when test-operated for 30 seconds inclined at an angle of 15 (30“ when specified for submarines) each side of the

22、vertical, in each of two vertical planes at right angles to each other. (Shipboard requirement, see 7.2) 3.5 Environmental suitability. The unit shall be capable of withstanding ships vibration and motion. Controls, switches, moving parts, and electrical circuits shall operate under shipboard condit

23、ions without malfunction, binding, excessive looseness, or damage, when tested in accordance with MIL-CTD-167/1, type I equipment. The unit shall be secured to the test machine in the same manner that it will be secured on shipboard. (Shipboard requirement, see 7.2) 3.6 Standards compliance. The uni

24、t shall be in accordance with and certified to meet the applicable requirements of NSF 18, UL 62, and UL 471. 3.7 Label plates. instruction plate, both attached to the front of the unit. They shall be readily visible during normal operating use and shall not adversely affect the life and utility of

25、the unit. 3.7.1 Data nameplate. The data nameplate shall contain the manufacturers name, model, serial number, date manufactured, and any other information needed to uniquely identify the unit. 3.7.2 Instruction plate. The instruction plate shall provide instructions for start-up, operation, and shu

26、t-down. 3.8 Finish. The unit shall have an exterior finish of the manufacturers standard commercial finish. 4. REGULATORY REQUIREMENTS The unit shall be provided with a data nameplate and an The offeror/contractor is encouraged to use recovered materials to the maximum extent practicable, in accorda

27、nce with paragraph 23.403 of the Federal Acquisition Regulation. 5. QUALITY ASSURANCE PROVISIONS 5.1 Product conformance. The product provided shall meet the salient, characteristics of this CID, conform to the producers own drawings, specifications, standards, and quality assurance practices, and b

28、e the same product offered for sale in the comercial market, or the same product that has been delivered to the Government for shipboard use on a previous procurement. compliance. The Government reserves the right to require proof of such 6. PACKAGING Preservation, packing, and marking shall be as s

29、pecified in the contract or purchase order. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- - A-A-59184 9018054 O000707 3T9 A-A- 5 9 10 4 7. NOTES 7.1 e e e e e e 7.2 in a Ordering data. Title, number, and date of this CID Size of dispenser requir

30、ed Capacity of syrup tanks, either 3 or 5 gallons When required, cold plate or ice bank Hose length required When required, manuals shall be in accordance with ASTM F 760 Shipboard requirement. Whenever a “(Shipboard requirement)“ is included paragraph under SALIENT CHARACTERISTICS, it is meant that

31、 the requirement is something that is not normally offered to the commercial market by the manufacturer . 7.3 Source of documents. 7.3.1 Military documents. Copies of documents required by manufacturers in connection with specific acquisition functions should be obtained from the contracting activit

32、y or as directed by the contracting officer. MIL-STD-1399 - Interface Standard for Shipboard Systems Section 300A MIL-STD-167/1 - Mechanical Vibrations of Shipboard Equipment (Type I - Electric Power, Alternating Environmental and Type II - Internally excited) 7.3.2 American Society for Testing and

33、Materials (ASTM) Standards. ASTM Standards are available from the American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohoken, PA 19428-2959. ASTM F 760 - Food Service Equipment Manuals 7.3.3 National Sanitation Foundation International (NSF) Standards. NSF Standards are avai

34、lable from the National Sanitation Foundation International, 3475 Plymouth Road, P.O. Box 130140, Ann Arbor, MI 48113-0140. NSF 18 - Manual Food and Beverage Dispensing Equipment 7.2.4 Underwriters Laborites (UL) Standards. UL Standards are available from the Underwriters Laboratories Inc., 333 Pfin

35、gston Road, Northbrook, IL 60062. UL 62 - Flexible Cord and Fixture Wire UL 471 - Comercial Refrigerators and Freezers 7.2.5 American Refrigeration Institute (ARI) Standards. AR1 Standards are available from the Air-Conditioning MN 55303-1592 MILITARY INTERESTS: Military Coordinating Activity CIVIL AGENCY COORDINATING ACTIVITIES: Navy - SH 5 GSA - FSS Preparing activity: Navy - SH (Project 7310-0893) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-