NAVY MIL-C-29240-1985 PERFORMANCE SPECIFICATIONS FOR CASEWORK MOVEABLE AND MODULAR FOR HOSPITAL LABORATORIES AND PHARMACIES《用于医院的实验室和药房转换和固定的生活环境调查的性能规格》.pdf

上传人:sofeeling205 文档编号:977751 上传时间:2019-03-13 格式:PDF 页数:17 大小:602.24KB
下载 相关 举报
NAVY MIL-C-29240-1985 PERFORMANCE SPECIFICATIONS FOR CASEWORK MOVEABLE AND MODULAR FOR HOSPITAL LABORATORIES AND PHARMACIES《用于医院的实验室和药房转换和固定的生活环境调查的性能规格》.pdf_第1页
第1页 / 共17页
NAVY MIL-C-29240-1985 PERFORMANCE SPECIFICATIONS FOR CASEWORK MOVEABLE AND MODULAR FOR HOSPITAL LABORATORIES AND PHARMACIES《用于医院的实验室和药房转换和固定的生活环境调查的性能规格》.pdf_第2页
第2页 / 共17页
NAVY MIL-C-29240-1985 PERFORMANCE SPECIFICATIONS FOR CASEWORK MOVEABLE AND MODULAR FOR HOSPITAL LABORATORIES AND PHARMACIES《用于医院的实验室和药房转换和固定的生活环境调查的性能规格》.pdf_第3页
第3页 / 共17页
NAVY MIL-C-29240-1985 PERFORMANCE SPECIFICATIONS FOR CASEWORK MOVEABLE AND MODULAR FOR HOSPITAL LABORATORIES AND PHARMACIES《用于医院的实验室和药房转换和固定的生活环境调查的性能规格》.pdf_第4页
第4页 / 共17页
NAVY MIL-C-29240-1985 PERFORMANCE SPECIFICATIONS FOR CASEWORK MOVEABLE AND MODULAR FOR HOSPITAL LABORATORIES AND PHARMACIES《用于医院的实验室和药房转换和固定的生活环境调查的性能规格》.pdf_第5页
第5页 / 共17页
点击查看更多>>
资源描述

1、MIL-C-27240 b5 M 777770b 02573q5 7 9 MIL-C-29240 10 May 1985 MILITARY SPECIFICATIONS CASEWORK, MOVEABLE AND MODULAR, FOR HOSPITAL LABORATORIES AND PHARMACIES, PERFORMANCE SPECIFICATIONS FOR, This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE

2、 1.1 Scope. This performance specification covers modular, moveable casework configurations for hospital laboratories and pharmacies. 1.2 Classification. Basic modular components of three types shall be sized and constructed so that theyzcan be fitted together as configurations of work stations in h

3、ospital laboratories and pharmacies. All dimensions in this specification are nominal unless stated otherwise and are for the purpose of establishing functional performance characteristics for moveable and modular casework components. Nominal dimensions are permitted to vary $r 1-1/2 inches. Greater

4、 variations in dimensions for storage components are permitted if equal or greater storage capacity is achieved. The modular components are: 1.2.1 Type I, work surfaces, Work surfaces shall be of four sizes with two variants. Size 1: 48 inches wide by 24 inches deep. Size 2: 48 inches wide by 30 inc

5、hes deep. Size 3: 24 inches wide by 24 inches deep. Size 4: 24 inches wide by 30 inches deep. Variant (a): Without sink. Variant (b): With sink. 1.2.2 Type II, storape components. Shall be of three classes. Beneficial comments (recommendations, additions, deletions) and any pertinent data which may

6、be of use in improving this document should be addressed to: Commanding Officer (Code 1561, Naval Construction Battalion Center, Port Hueneme, CA 93043, by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or . i- % FSC 6530 T

7、HIS DOCUMENT CONTAINS /7 PAGES Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-27240 65 H 777770b 02573qb 7 MIL-C-29240 1.2.2.1 Class A, above work surface storaae. Shall be of two sizes with two variants. Dimensions are exterior dimensions. Wi

8、dth dimensions shall be no greater than the dimension shown and no smaller than 1-1/2 inch less than the dimension shown. Size 1: 48 inches wide, 18 inches deep, and 18 inches high. Size 2: 24 inches wide, 18 inches deep, and 18 inches high, Variant (a): Open storage. Variant (b): Closed storage. 1.

9、2.2.2 Class B, below work surface storage. Shall be of two sizes with four variants. dimensions. no smaller than 1-1/2 inch less than the dimension shown. Dimensions of these storage components are exterior Width dimensions shall be no greater than the dimension shown and Size 1: 24 inches wide, 24

10、inches deep, and 24 inches high. Size 2: 24 inches wide, 24 inches deep, and 30 inches high. Variant (a): Two shelves, open. Variant (b): Two shelves, one door. Variant (c): Four drawers, each 6 inches high. Variant (d): Five drawers, each 6 inches high. 1.2.3 Type III, partitions. Shall be of six s

11、izes With three variants. Size 1: 48 inches wide by 78 inches high. Size 2: 48 inches wide by 48 inches high, Size 3: 48 inches wide by 30 inches high, Size 4: 24 inches wide by 78 inches high. Size 5: 24 inches wide by 48 inches high. Size 6: 24 inches wide by 30 inches high. Variant (a): With elec

12、trical subsystem. Variant (b): Variant (c): No electrical service or computer cabling. With electrical subsystem and conduit for computer cabling. 1.3 Configurations of components. Type I, II, and III components shall be capable of being assembled into configurations for work stations for laboratori

13、es and pharmacies. The configurations are shoh below. 1.3.1 Configuration A. Shall consist of the following components and variants : Type I, Work Surface: 4 Size 2, Variant (a) 2 Size 4, Variant (a) Type II, Storage: 4 Class A, Size 1, Variant (a) or (b) 4 Class B, Size 2, Variant (b) 4 Class B, Si

14、ze 2, Variant (d) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-292LI0 65 7977706 02573q7 O I- MIL-C-29240 Type III, Partitions: 2 Size 1, Variant (b) 2 Size 4, Variant (b) 1.3.2 Configuration B. Shall consist of the following components and

15、variants : Type I, Work Surfaces: 4 Size 2, Variant (a) 1 Size 4, Variant (a) 1 Size 4, Variant (b) Type II, Storage: Same as Configuration A. - Type III, Partitions: Same as Configuration A. 1.3.3 Configuration C. Shall consist of the following components and variants : Type I, Work Surfaces: 4 Siz

16、e 2, Variant (a) 2 Size 4, Variant (a) Type II, Storage: 4 Class B, Size 2, Variant (b) 4 Class B, Size 2, Variant (d) Type III, Partitions: 2 Size 2, Variant (b) 2 Size 5, Variant (b) 1.3.4 Configuration D. Shall consist of the following components and variants : Type I, Work Surfaces: 4 Size 2, Va

17、riant (a) 1 Size 4, Variant (a) 1 Size 4, Variant (b) Type II, Storage: Same as Configuration C. Type III, Partitions: Same as Configuration C. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-23240 b5 3339306 0253348 2 MIL-C-29240 1.3.5 Confi

18、Ruration E. Shall consist of the following components and varianls : Type I, Work Surfaces: 2 Size i, Variant (a) 2 Size 3, Variant (a) Type 11, Storage: 2 Class A, Size 1, Variant (a) or (b) 4 Class B, Size 1, Variant (b) * 4 Class B, Size 1, Variant (c) Type III, Partitions: 2 Size 1, Variant (b)

19、2 Size 4, Variant (b) 1.3.6 Configuration F, Shall consist of the following components and variants : Type I, Work Surfaces: 2 Size 1, Variant (a) 1 Size 3, Variant (a) 1 Size 3, Variant (b) Type II, Storage: Same as Configuration E. Type III, Partitions: Same as Configuration E. 1.3.7 Configuration

20、 G, Shall consist of the following components and variants : Type I, Work Surfaces: 8 Size 4, Variant (a) Type II, Storage: 6 Class A, Size 2, Variant (a) or (b) 8 Class B, Size 2, Variant (a) Type III, Partitions: 4 Size 2, Variant (b) 1.3.8 Configuration H. Shall consist of the following component

21、s and variants : Type I, Work Surfaces: 3 Size 1, Variant (a) , :e- 4 . Y Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-292LlO 651 7777706 02573Ll7 4 O a a MIL-C-24240 Type II, Storage: 6 Class B, Size 2, Variant (a) Type III, Partitions: 3 S

22、ize 1, Variant (c) 2. APPLICABLE DOCUMENTS 2,l Government documents. 2.1.1 Specifications and standards. Unless otherwise specified, the following specifications and standards of the issue listed in that issue of the Department of Defense Index of Specifications and Standards (DODISS) specified in t

23、he solicitation, form a part of this specification to the extent specified herein. STANDARDS MILITARY MIL-STD-129 - Marking for Shipment and Storage. (Copies of specifications, standards, handbooks, drawings, and publications required by manufacturers in connection with specific acquisition function

24、s should be obtained from the contracting activity or as directed by the contracting officer,) 2.2 Other publications. The following documents form a part of this specification to the extent specified herein, which are indicated as DOD adopted shall be the issue listed in the current DODISS and the

25、supplement thereto, if applicable. The issues of the documents AMERICAN NATIONAL STANDARDS INSTITUTE, INC. (ANSI) A112.9.5 A156.11 - Auxiliary Locks. - Stainless Steel Plumbing Fixtures. (Application far copies should be addressed to the American National Standards Instiute, Inc., 1430 Broadway, New

26、 York, NY 10008.) NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) LD3-1980 - High Fressure Decorative Laminates. (Application for copies should be addressed to National Electrical Manufacturers Association, 2102 L Street, NW, Washington, D.C. 20037,) NATIONAL SANITATION FOUNDATION (NSF) No. 30

27、- Cabinetry and Laboratory Furniture for Hospitals. (Application for copies should be addressed to National Sanitation Foundation, 3475 Plymouth Road, P. O. Box 1468, Ann Arbor, MI 48106.) 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NIL-C-272qO

28、 65 U 7779706 0257350 O W MIL-C-29240 (Industry association specifications and standards are generally available for reference from libraries. groups and Feaeral agencies.) They are also distributed among technical 2.3 Order of Precedence. If there is a conflict between the text of this specificatio

29、n and the references cited, the text of this specification shall take precedence. 3. REQUIREMENTS. 3.1 Description, Casework components shall be designed and constructed to meet all requirements of this specification. Work Surface; Type II, Storage Units; and Type III, Partitions, and variants of th

30、ese. together to form configurations A through H. Casework components are Type I, These components and variants shall be such that they can be fitted 3.2 Manufacturers performance requirements. The casework components, variants, and configurations shall be standard comercial products conforming to d

31、esign and installation requirements. 3.2.1 Standard commercial product. The casework shall, as a minimum, be in accordance with the requirements of this specification and shall be the manufacturers standard commercial product. Additional or better features that are not prohibited by this specificati

32、on but are a part of the manufacturers standard commercial product shall be included in the casework. A standard commercial product is a product that has been sold or is being currently offered for sale on the commercial market through advertisements, manufacturers catalogs, or brochures and is the

33、latest production model. 3.2.2 Desim. Minor deviations from the specified dimensions, other than limiting dimensions, will not be considered cause for rejection provided the item is suitable for the purpose intended and is the manufacturers cataloged stock product substantially equivalent to the ite

34、m described in this specification. requirements and options specified, unless such deviations are numbered, notated, and described by the manufacturer and are approved by the contracting officer . The manufacturer shall have no design deviations from the 3.2.3 Installation. The manufacturer shall pr

35、ovide and assemble configurations of casework at the site and in the specific locations indicated by the contracting o.fficer or his representative. variants shall be attached to the existing building systems by the manufacturer (see 6.2.1). Plumbing and electrical 3.3 Modular requirements. Componen

36、ts and component variants of the casework configurations shall be modular in that they shall be interchangeable with other components of the same type, class, and size in their specified configuration or other configurations of paragraph 1.3 of this specification. They also shall be modular in that

37、the relative positions of components may be interchanged within a work station configuration. drawers, trays, and other shelf components for similar storage units shall be interchangeable without tools. Subcomponents such as Provided by IHSNot for ResaleNo reproduction or networking permitted withou

38、t license from IHS-,-,-MIL-C-292Li b5 99999Ob 0259351 2 = MIL-C-29240 3.4 Movability. Components with any component variants shall be such that they can be repositioned within a configuration or moved to a different area. It shall be possible to reposition or move an unloaded component of any Type,

39、Class, or Size using no more than simple hand tools, such as screwdrivers, pliers, and wrenches, and using no more than two unskilled workers. 3.5 Clearance and adjustability. The components and variants shall have the clearances specified and shall be incrementally adjustable vertically. 3.5.1 Type

40、 I, work surface. Components shall be adjustable from 26 inches to 42 inches above the floor in increments no greater than 1 inch. 3.5.2 Type II, Class A, above work surface. Storage components shall be mountable 48 inches or more above the floor, but the tops of these components shall not be more t

41、han 78 inches above the floor. Components shall be adjustable in height in increments no greater than 2-1/4 inches. 3.5.3 Type II, Class B, below work surface. Storage components shall be mounted a minimum of 6 inches above the floor and shall have height adjustments in increments no greater than 2-

42、1/4 inches. 3.5.4 Type III, partitions. Partitions shall permit the components suspended on them to be adjusted vertically in increments of no less than 1 inch for work surfaces and 2-1/4 inches for storage components. 3.5.5 Component variants. Electrical systems, sinks, and computer conduits shall

43、be adjustable to the same degree as the components on which they are mounted. 3.6 Cleanability. Casework surfaces shall have a cleanability equal to a No. 4 finish (150 grit) on 300 series stainless steel, which once clean can demonstrate a residual soil of no more than 70 micrograms per square inch

44、 (NSF No. 30, paragraphs 3.1.1 and 3.2.1). Surfaces shall be cleanable with bacteriocidal agents such as phenolic compounds or quaternary ammonium components (quats) without alteration of the finish (NSF No. 30, paragraph 3.2.1). 3.7 Materials. The materials used in the components and component vari

45、ants of the casework shall be resistant to chemicals, heat, and fire as set forth below. Surfaces shall be free of crevices, cracks, pits, or inclusions and shall have rounded or beveled edges and corners. There shall be no protrusions that could cause bodily harm on impact. 3.7.1 Chemical resistanc

46、e. When exposed to chemicals listed in Appendix A of this specification, the surface of components and variants shall show no deteriation other than a slight change of gloss, slight discoloration, or a temporary softening of the finish with no loss of adhesion or film protection (NSF No. 30, paragra

47、phs 3.2.2). 3.7.2 Heat resistance. The surface of components and variants, when exposed to temperatures up to 356 degrees Fahrenheit (“FI for 20 minutes, shall show no blisters, cracks, or breakdown of the surface and no perceivable change in color or surface texture. (NEMA LD3-1980, Section LD3-3.0

48、6). 7 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-29240 3.7.3 Fire resistance. The components and variants shall be non- combustible at temperatures of 356F or less. 3.8 Color. Color shall be as selected by the contracting officer or his re

49、presentative from the complete range of the manufacturers standard colors. 3.9 Load capacity. Type I, work surfaces and the shelves of Type II, Class A, above work surface storage components shall have a load capacity of no less than 30 pound-force per square foot and a maximum deflection of no more than 1/200th of the space when so loaded. 3.9.1 Type II, Class B, below work surface storage component shelves shall have a load