NAVY MIL-DTL-16377 80-2008 FIXTURES LIGHTING T8 FLUORESCENT GENERAL LIGHTING 51 WATTS 120 VOLTS 60 HERTZ WATERTIGHT SYMBOLS 333 1T8 333 2T8 341 1T8 341 2T8 333 1T8RC 341 4T8 342 2T.pdf

上传人:fuellot230 文档编号:978464 上传时间:2019-03-13 格式:PDF 页数:15 大小:200.06KB
下载 相关 举报
NAVY MIL-DTL-16377 80-2008 FIXTURES LIGHTING T8 FLUORESCENT GENERAL LIGHTING 51 WATTS 120 VOLTS 60 HERTZ WATERTIGHT SYMBOLS 333 1T8 333 2T8 341 1T8 341 2T8 333 1T8RC 341 4T8 342 2T.pdf_第1页
第1页 / 共15页
NAVY MIL-DTL-16377 80-2008 FIXTURES LIGHTING T8 FLUORESCENT GENERAL LIGHTING 51 WATTS 120 VOLTS 60 HERTZ WATERTIGHT SYMBOLS 333 1T8 333 2T8 341 1T8 341 2T8 333 1T8RC 341 4T8 342 2T.pdf_第2页
第2页 / 共15页
NAVY MIL-DTL-16377 80-2008 FIXTURES LIGHTING T8 FLUORESCENT GENERAL LIGHTING 51 WATTS 120 VOLTS 60 HERTZ WATERTIGHT SYMBOLS 333 1T8 333 2T8 341 1T8 341 2T8 333 1T8RC 341 4T8 342 2T.pdf_第3页
第3页 / 共15页
NAVY MIL-DTL-16377 80-2008 FIXTURES LIGHTING T8 FLUORESCENT GENERAL LIGHTING 51 WATTS 120 VOLTS 60 HERTZ WATERTIGHT SYMBOLS 333 1T8 333 2T8 341 1T8 341 2T8 333 1T8RC 341 4T8 342 2T.pdf_第4页
第4页 / 共15页
NAVY MIL-DTL-16377 80-2008 FIXTURES LIGHTING T8 FLUORESCENT GENERAL LIGHTING 51 WATTS 120 VOLTS 60 HERTZ WATERTIGHT SYMBOLS 333 1T8 333 2T8 341 1T8 341 2T8 333 1T8RC 341 4T8 342 2T.pdf_第5页
第5页 / 共15页
点击查看更多>>
资源描述

1、AMSC N/A FSC 6210 INCH-POUND MIL-DTL-16377/80 18 December 2008 DETAIL SPECIFICATION SHEET FIXTURES, LIGHTING; T8 FLUORESCENT, GENERAL LIGHTING, 51 WATTS, 120 VOLTS, 60 HERTZ, WATERTIGHT SYMBOLS 333.1T8, 333.2T8, 341.1T8, 341.2T8, 333.1T8RC, 341.4T8, 342.2T8, AND 342.3T8 This specification is approve

2、d for use by the Naval Sea Systems Command, Department of the Navy, and is available for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-16377. All dimensions in inches

3、. For tolerances, other than specified herein, see 3.5.2 of MIL-DTL-16377. NOTES: 1. Symbols 333.2T8 and 342.3T8 use identical construction with flush mounting flange not shown. 2. Symbols 341.1T8 and 341.2T8 use identical construction with lens mounted black louvers not shown. 3. Symbols 333.1T8RC

4、and 341.4T8 use identical construction with center lamp shield not shown. FIGURE 1. Typical view of symbols 333.1T8 and 342.2T8. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/80 2 NOTE: 1. TYPE II Label required for all fixtures. FIGU

5、RE 2. Typical section for symbols 333.1T8 and 342.2T8. FIGURE 3. Typical section for symbols 333.2T8 and 342.3T8. FIGURE 4. Flush mounting dimension for symbols 333.2T8, 341.4T8, and 342.3T8. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16

6、377/80 3 FIGURE 5. Standard mounting dimensions utilizing shock mounts for symbols 333.1T8, 341.1T8, 333.1T8RC, and 342.2T8. NOTE: 1. Symbol 341.2T8 has identical construction with flush mounting flange not shown. FIGURE 6. Typical view of symbol 341.1T8 with lens mounted black louvers. NOTE: 1. TYP

7、E II Label required for all fixtures. FIGURE 7. Typical section for symbol 341.1T8 with lens mounted black louvers. FIGURE 8. Typical section for symbol 341.2T8 with lens mounted black louvers. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-

8、16377/80 4 FIGURE 9. Flush mounting dimension for symbol 341.2T8 with lens mounted black louvers. NOTE: 1. Symbol 341.4T8 has identical construction with flush mounting flange not shown. FIGURE 10. Typical view of symbol 333.1T8RC with center lamp shielded. Provided by IHSNot for ResaleNo reproducti

9、on or networking permitted without license from IHS-,-,-MIL-DTL-16377/80 5 NOTE: 1. Symbol 341.4T8 has identical construction with flush mounting flange not shown. FIGURE 11. Typical section for symbol 333.1T8RC with center lamp shielded. FIGURE 12. Typical wiring diagram. Provided by IHSNot for Res

10、aleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/80 6 FIGURE 13. Candela distribution curves, white diffusing window, symbols 333.1T8 and 333.2T8. FIGURE 14. Candela distribution curves, prismatic window, symbols 342.2T8 and 342.3T8. Provided by IHSNot for Resale

11、No reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/80 7 FIGURE 15. Candela distribution curves, (red mode) one red filter center lamp energized, two white lamps off, symbols 333.1T8RC and 341.4T8. FIGURE 16. Candela distribution curves, (white mode) two white lamps en

12、ergized, red center lamp off, symbols 333.1T8RC and 341.4T8. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/80 8 FIGURE 17. Candela distribution curves, three white lamps, Symbols 341.1T8 and 341.2T8. TABLE I. Numerical candela distrib

13、ution curves, white diffusing window, symbols 333.1T8 and 333.2T8. Candela distribution Candela distribution Vertical angle 0-degree 90-degree Vertical angle 0-degree 90-degree 0 786 786 95 8 62 5 781 783 105 6 39 15 745 760 115 4 26 25 677 709 125 3 17 35 582 634 135 0 10 45 469 540 145 0 3 55 353

14、436 155 0 0 65 234 323 165 0 0 75 120 211 175 0 0 85 27 124 180 0 0 90 9 89 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/80 9 TABLE II. Numerical candela distribution curves, prismatic window, symbols 342.2T8 and 342.3T8. Candela dis

15、tribution Candela distribution Vertical angle 0-degree 90-degree Vertical angle 0-degree 90-degree 0 910 910 95 8 48 5 904 910 105 6 26 15 872 906 115 5 22 25 810 881 125 3 15 35 713 817 135 1 9 45 577 709 145 0 4 55 378 566 155 0 1 65 195 381 165 0 0 75 88 227 175 0 0 85 30 119 180 0 0 90 9 76 TABL

16、E III. Numerical candela distribution curves, (red mode) one red filter center lamp energized, two white lamps off, symbols 333.1T8RC and 341.4T8. Candela distribution Candela distribution Vertical angle 0-degree 90-degree Vertical angle 0-degree 90-degree 0 1.73 1.73 95 .01 .01 5 1.73 1.68 105 .01

17、.01 15 1.63 1.44 115 .01 .01 25 1.44 .78 125 .01 .01 35 1.2 .22 135 .01 .01 45 .92 .18 145 .01 .01 55 .62 .13 155 0 .01 65 .33 .08 165 0 0 75 .12 .05 175 0 0 85 .03 .03 180 0 0 90 .02 .02 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/

18、80 10 TABLE IV. Numerical candela distribution curves, (white mode) two white lamps energized, red center lamp off, symbols 333.1T8RC and 341.4T8. Candela distribution Candela distribution Vertical angle 0-degree 90-degree Vertical angle 0-degree 90-degree 0 443 443 95 6 40 5 440 443 105 5 23 15 421

19、 449 115 3 18 25 385 424 125 2 13 35 332 367 135 1 9 45 267 296 145 1 5 55 195 250 155 0 2 65 124 211 165 0 0 75 62 147 175 0 0 85 17 84 180 0 0 90 6 58 TABLE V. Numerical candela distribution curves, three white lamps energized, symbols 341.1T8 and 341.2T8. Candela distribution Candela distribution

20、 Vertical angle 0-degree 90-degree Vertical angle 0-degree 90-degree 0 608 608 55 4 3 5 540 551 65 1 1 15 338 350 75 0 0 25 116 156 85 0 0 35 20 27 90 0 0 45 8 8 PHOTOMETRIC DATA: Photometry reports based on LM-41 and other pertinent IESNA procedures. Plane: 0 degrees is parallel to lamps, 90 degree

21、s is perpendicular to lamps. Electrical values: 120 volts, 60 hertz, 53.7 watts input power (three lamps energized). Ambient temperature: 251 C. Lamps: GE F17T8-SP41-ECO (seasoned for at least 100 hours). Lamps correction: lamps rated at 1325 lumens. Ballast: furnished with fixture, see MIL-DTL-1637

22、7/81 for specification. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/80 11 REQUIREMENTS: CLASSIFICATION: Type: 1 (Fluorescent). Class: 2 (General). SYMBOL NUMBERS: 333.1T8: Complete lighting fixture assembly, standard mounting, with

23、three 17-watt T8 cool white fluorescent lamps and white diffusing window assembly. 333.2T8: Complete lighting fixture assembly, flush mounting, with three 17-watt T8 cool white fluorescent lamps and white diffusing window assembly. 341.1T8: Complete lighting fixture, standard mounting, blue and whit

24、e (Command Information Center (CIC) Lighting), clear black shielded with three 17-watt T8 cool white fluorescent lamps. 341.2T8: Complete lighting fixture, flush mounting, blue and white (Command Information Center (CIC) Lighting), clear black shielded, with three 17-watt T8 cool white fluorescent l

25、amps. 333.1T8RC: Complete lighting fixture assembly, standard mounting, red filter on center lamp, center lamp shielded (berthing area lighting) with three 17-watt T8 cool white fluorescent lamps and white diffusing window assembly. 341.4T8: Complete lighting fixture assembly, flush mounting, red fi

26、lter on center lamp, center lamp shielded (berthing area lighting) with three 17-watt T8 cool white fluorescent lamps and white diffusing window assembly. 342.2T8: Complete lighting fixture assembly, standard mounting, with three 17-watt T8 cool white fluorescent lamps and clear and white prismatic

27、window assembly. 342.3T8: Complete lighting fixture assembly, flush mounting, with three 17-watt T8 cool white fluorescent lamps and clear and white prismatic window assembly. DESIGN: Electrical rating: 51 watts, 120 volts, 60 hertz, ungrounded electrical distribution system total input power: 53.7

28、watts at 120 volts. Dimension and configurations: See figures 1, 2, 3, 6, 7, 8, 10, and 11. Photometric data: See figures 13, 14, 15, 16, and 17; and tables I, II, III, IV, and V. Wiring diagram: See figure 12. Ballast: See MIL-DTL-16377/81 for specification. Mounting dimensions: Symbols 333.1T8, 34

29、1.1T8, 333.1T8RC, and 342.2T8: Standard mounting (surface), see figure 5. Symbols 333.2T8, 341.2T8, 341.4T8, and 342.3T8: Flush mounting (recessed), see figures 4 and 9. Window assembly: Symbols 333.1T8 and 333.2T8: White window, see table VI and figure 27 of MIL-DTL-16377. Symbols 341.1T8 and 341.2

30、T8: White window with louvers, see table VI and figures 7, 8, and 9. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/80 12 Symbols 333.1T8RC and 341.4T8: White window with center lamp shielded, see table VI and figures 10 and 11. Symbol

31、s 342.2T8 and 342.3T8: Prismatic window, see table VI and figure 27 of MIL-DTL-16377. Enclosure: Watertight; see 3.5.11 of MIL-DTL-16377 drip-proof (15 degrees) for 341.1T8 and 341.2T8. Cable: 10 feet (minimum) of type LSTHOF-3 in accordance with MIL-DTL-24643/3. Weight: Symbols 333.1T8 and 342.2T8:

32、 Not to exceed 15 pounds, 11 ounces. Symbols 333.2T8 and 342.3T8: Not to exceed 17 pounds, 14 ounces. Symbol 341.1T8: Not to exceed 19 pounds, 4 ounces. Symbol 341.2T8: Not to exceed 21 pounds, 7 ounces. Symbol 333.1T8RC Not to exceed 16 pounds. Symbol 341.4T8 Not to exceed 18 pounds. DESIGNATION AN

33、D MARKING: The following labels shall be furnished in accordance with MIL-DTL-16377 applied as shown on figures 1, 3, and 8. a. Two Type I labels, equipment identification, reference MIL-DTL-16377 figure 11, shall include manufacturer and address, one located on back and other located on an inner no

34、nreflecting surface. b. One Type II label, circuit wiring information, reference MIL-DTL-16377 figure 12, located on outside surface adjacent to cable entrance. c. One Type IV label, repair parts, reference MIL-DTL-16377 figure 14, information to be shown shall include “USE THE FOLLOWING REPAIR PART

35、S ONLY.” List all standard parts shown in table VI, located on an inner nonreflecting surface. EXAMINATION AND TESTS Examination and tests shall be as specified in MIL-DTL-16377 and the following: First article testing/inspection: Complete fixtures: See table VII. Window assemblies: See table VIII.

36、Comparison inspection: See tables VII and VIII. Conformance inspection: See MIL-DTL-16377. Inspection of product for delivery: Examination: See MIL-DTL-16377. Conformance test: See MIL-DTL-16377. Examination for preparation of delivery: See MIL-DTL-16377. Provided by IHSNot for ResaleNo reproduction

37、 or networking permitted without license from IHS-,-,-MIL-DTL-16377/80 13 GENERAL INFORMATION: Table VI Fixture standard parts. Table VII Complete fixture first article tests. Table VIII. Window assembly first article tests. Table IX. Complete fixture part numbers. TABLE VI. Standard parts. Name Mil

38、itary p/n or specification National Stock Number (NSN) Remarks Lamp Commercial identification F17T8/CW 6240-01-391-6027 - Lamplock M16377/40-003 - -Lampholder UL 542 6250-00-284-0481 Commercial Ballast M16377/81-001 - Integrated starter type Shockmount M16377/41-008 6210-01-393-4302 0.067 steel, zin

39、c plated Window assembly, diffusing M16377/12-001 6210-00-295-28491/Window assembly, prismatic M16377/12-003 6210-00-725-9030 1/Window assembly, with louvers M16377/12-004 6210-00-814-5914 1/Window assembly, with center lamp shielded - - 1/Filter, 17-watt T8 fluorescent lamp (DARK ADAPTATION) M16377

40、/42-010 - Red transparent NOTE: 1/Window assemblies are the same as T12 lamp fixtures (MIL-DTL-16377/12). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/80 14 TABLE VII. First article tests and comparison inspection for complete fixtur

41、es.1/Test Requirement Test method Remarks Examination 3.13 4.5 - Operation 3. 4.8.1 -Electromagnetic interference 3.6.14 4.8.16 - Electrical equipment interface testing requirements: MIL-STD-1399-300 MIL-STD-1399-300 MIL-STD-1399-300 2/3/Dielectric withstanding voltage 3.6.15 4.8.2 4/ Insulation res

42、istance 3.6.16 4.8.3 4/ Enclosure effectiveness 3.5.11 4.8.14.4 4/ Watertight, drip-proof for 341.1T8 and 341.2T8. Shock 3.5.12 4.8.7 4/ Vibration 3.5.13 4.8.8 4/ Enclosure effectiveness 3.5.11 4.8.14.4 4/ Watertight, drip-proof for 341.1T8 and 341.2T8. Dielectric withstanding voltage 3.6.15 4.8.2 4

43、/ Insulation resistance 3.6.16 4.8.3 4/ Noise 3.5.14 4.8.9 - Continuity of grounding 3.6.13.4 4.8.12 - Light output 3.7.1 4.8.6.1 - Optical uniformity 3.7.4.1.1 4.8.4 - Stress relief 3.8.5.3 4.8.5 - Magnetic permeability 3.4.8 4.8.18 - NOTES: 1/Requirements and test methods use MIL-DTL-16377. 2/Less

44、 than 1KVA exception not applicable for input wave form THD. 3/Solid-state components shall be subject to 250 positive and 250 negative spikes (500 total spikes), one spike per minute, using test method identified in MIL-STD-1399-300. 4/Tests shall be performed in the order specified. Provided by IH

45、SNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/80 15 TABLE VIII. First article tests and comparison inspection for window assemblies.1/Test Requirement paragraph Test paragraph Remarks Examination 3.13 4.5 - Optical uniformity 3.7.4.1.1 4.8.4 - Stre

46、ss relief 3.8.5.3 4.8.5 - Shock 3.5.12 4.8.7 2/Vibration 3.5.13 4.8.8 2/Enclosure effectiveness 3.5.11 4.8.14.4 2/ Watertight, drip-proof for 341.1T8 and 341.2T8. Light output 3.7.1 4.8.6.1 Candela distribution NOTES: 1/Requirements and test methods use MIL-DTL-16377. 2/Tests shall be performed in t

47、he order specified. TABLE IX. Complete fixture part numbers. Name Military p/n Complete fixture, symbol 333.1T8 M16377/80-333.1T8 Complete fixture, symbol 333.2T8 M16377/80-333.2T8 Complete fixture, symbol 341.1T8 M16377/80-341.1T8 Complete fixture, symbol 341.2T8 M16377/80-341.2T8 Complete fixture,

48、 symbol 333.3T8RC M16377/80-333.3T8RC Complete fixture, symbol 341.4T8 M16377/80-341.4T8 Complete fixture, symbol 342.2T8 M16377/80-342.2T8 Complete fixture, symbol 342.3T8 M16377/80-342.3T8 Custodians: Preparing Activity: Army CR4 Navy SH Navy SH (Project 6210-2006-005) Air Force 99 Review Activities: Navy AS, CG Air Force 03 DLA GS2 GSA FAS NOTE: The activities listed above were interested in this document as of the date of this do

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1