NAVY MIL-DTL-16377 82-2008 FIXTURES LIGHTING T8 FLUORESCENT EMERGENCY LIGHTING 17 WATTS 120 VOLTS 60 HERTZ WATERTIGHT SYMBOLS 331 1T8EM 331 2T8EM 347 2T8EM AND 347 3T8EM《照明设备固定装置 防.pdf

上传人:eastlab115 文档编号:978466 上传时间:2019-03-13 格式:PDF 页数:12 大小:135.19KB
下载 相关 举报
NAVY MIL-DTL-16377 82-2008 FIXTURES LIGHTING T8 FLUORESCENT EMERGENCY LIGHTING 17 WATTS 120 VOLTS 60 HERTZ WATERTIGHT SYMBOLS 331 1T8EM 331 2T8EM 347 2T8EM AND 347 3T8EM《照明设备固定装置 防.pdf_第1页
第1页 / 共12页
NAVY MIL-DTL-16377 82-2008 FIXTURES LIGHTING T8 FLUORESCENT EMERGENCY LIGHTING 17 WATTS 120 VOLTS 60 HERTZ WATERTIGHT SYMBOLS 331 1T8EM 331 2T8EM 347 2T8EM AND 347 3T8EM《照明设备固定装置 防.pdf_第2页
第2页 / 共12页
NAVY MIL-DTL-16377 82-2008 FIXTURES LIGHTING T8 FLUORESCENT EMERGENCY LIGHTING 17 WATTS 120 VOLTS 60 HERTZ WATERTIGHT SYMBOLS 331 1T8EM 331 2T8EM 347 2T8EM AND 347 3T8EM《照明设备固定装置 防.pdf_第3页
第3页 / 共12页
NAVY MIL-DTL-16377 82-2008 FIXTURES LIGHTING T8 FLUORESCENT EMERGENCY LIGHTING 17 WATTS 120 VOLTS 60 HERTZ WATERTIGHT SYMBOLS 331 1T8EM 331 2T8EM 347 2T8EM AND 347 3T8EM《照明设备固定装置 防.pdf_第4页
第4页 / 共12页
NAVY MIL-DTL-16377 82-2008 FIXTURES LIGHTING T8 FLUORESCENT EMERGENCY LIGHTING 17 WATTS 120 VOLTS 60 HERTZ WATERTIGHT SYMBOLS 331 1T8EM 331 2T8EM 347 2T8EM AND 347 3T8EM《照明设备固定装置 防.pdf_第5页
第5页 / 共12页
点击查看更多>>
资源描述

1、AMSC N/A FSC 6210 INCH-POUND MIL-DTL-16377/82 18 December 2008 DETAIL SPECIFICATION SHEET FIXTURES, LIGHTING; T8 FLUORESCENT, EMERGENCY LIGHTING, 17 WATTS, 120 VOLTS, 60 HERTZ, WATERTIGHT, SYMBOLS 331.1T8EM, 331.2T8EM, 347.2T8EM, AND 347.3T8EM This specification is approved for use by the Naval Sea

2、Systems Command and is available for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-16377. All dimensions in inches. For tolerances, other than specified herein, see 3

3、.5.2 of MIL-DTL-16377. FIGURE 1. Typical view of symbols 331.1T8EM and 347.2T8EM, symbols 331.2T8EM and 347.3T8EM use identical construction with flush mounting flange not shown. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/82 2 NOTE

4、S: 1. Symbols 331.2T8EM and 347.3T8EM use identical battery test switch construction with additional switch hardware (not shown) for switch operation below ceiling. 2. Type II label required on all fixtures. FIGURE 2. Typical section for symbols 331.1T8EM and 347.2T8EM. FIGURE 3. Typical section for

5、 symbols 331.1T8EM and 347.2T8EM. NOTE: 1. Type II Label required for all fixtures. FIGURE 4. Typical section for symbols 331.2T8EM and 347.3T8EM. FIGURE 5. Typical side view for symbols 331.2T8EM, 331.2T8EM, 347.2T8, and 347.3T8EM. Provided by IHSNot for ResaleNo reproduction or networking permitte

6、d without license from IHS-,-,-MIL-DTL-16377/82 3 FIGURE 6. Flush mounting dimension for symbols 331.2T8EM and 347.3T8EM. FIGURE 7. Standard mounting dimensions utilizing shock mounts for symbols 331.1T8EM and 347.2T8EM. Provided by IHSNot for ResaleNo reproduction or networking permitted without li

7、cense from IHS-,-,-MIL-DTL-16377/82 4 NOTES: 1. The black input conductor is the only switched power lead to the fixture, used for normal external on/off lamp control. 2. The white and green input conductors shall be connected directly to the power source and remain continuously energized for emerge

8、ncy lamp battery charging. The white and green input conductors shall not have power interrupted by on/off control switches. 3. The white input conductor is shared by the normal lamp circuit and by the emergency circuit. FIGURE 8. Typical wiring diagram. FIGURE 9. Candela distribution curves, white

9、diffusing window, symbols 331.1T8EM and 331.2T8EM. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/82 5 FIGURE 10. Candela distribution curves, prismatic window, symbols 347.2T8EM and 347.3T8EM. FIGURE 11. Candela distribution curves, e

10、mergency mode. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/82 6 TABLE I. Numerical candela distribution, white diffusing window, symbols 331.1T8EM and 331.2T8EM. Candela distribution Candela distribution Vertical angle 0-degree 90-d

11、egree Vertical angle 0-degree 90-degree 0 228 228 95 1 46 5 227 227 105 0 35 15 216 223 115 0 26 25 195 211 125 0 19 35 166 193 135 0 13 45 132 172 145 0 8 55 98 150 155 0 4 65 64 125 165 0 0 75 32 95 175 0 0 85 7 66 180 0 0 90 2 55 TABLE II. Numerical candela distribution, prismatic window, symbols

12、 347.2T8 and 347.3T8. Candela distribution Candela distribution Vertical angle 0-degree 90-degree Vertical angle 0-degree 90-degree 0 231 231 95 2 13 5 231 231 105 2 6 15 223 233 115 1 6 25 207 231 125 0 5 35 182 231 135 0 4 45 147 208 145 0 2 55 97 167 155 0 1 65 52 149 165 0 0 75 23 115 175 0 0 85

13、 9 51 180 0 0 90 2 25 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/82 7 TABLE III. Numerical candela distribution, emergency mode. Candela distribution Candela distribution Vertical angle 0-degree 90-degree Vertical angle 0-degree 90

14、-degree 0 56 56 95 8 0 5 56 55 105 4 0 15 54 53 115 3 0 25 51 48 125 2 0 35 46 41 135 1 0 45 41 33 145 1 0 55 35 25 155 0 0 65 28 17 165 0 0 75 21 8 175 0 0 85 14 2 180 0 0 90 10 1 PHOTOMETRIC DATA: Photometry reports based on LM-41 and other pertinent IESNA procedures. Plane: 0 degrees is parallel

15、to lamp, 90 degrees is perpendicular to lamp. Electrical values: 120 volts, 60 hertz, 18.0 watts+4.0 watts (battery charging circuit)=22.0 watts total. Ambient temperature: 251C. Lamp: GE F17T8-SP41-ECO (seasoned for at least 100 hours). Lamp correction: lamp rated at 1325 lumens. Ballast: Furnished

16、 with fixture, see MIL-DTL-16377/81 for 17-watt lamp specification, MIL-DTL-16377/77 for emergency ballast specification. REQUIREMENTS: CLASSIFICATION: Type: I (fluorescent). Class: 2 (general). SYMBOL NUMBERS: 331.1T8EM: Complete lighting fixture assembly, standard mounting, with one 17-watt T8 coo

17、l white fluorescent lamp and white diffusing window assembly, includes emergency battery/ballast circuit for emergency lighting. 331.2T8EM: Complete lighting fixture assembly, flush mounting, with one 17-watt T8 cool white fluorescent lamp and white diffusing window assembly, includes emergency batt

18、ery/ballast circuit for emergency lighting. 347.2T8EM: Complete lighting fixture assembly, standard mounting, with one 17-watt T8 cool white fluorescent lamp, clear and white prismatic window assembly, includes emergency battery/ballast circuit for emergency lighting. Provided by IHSNot for ResaleNo

19、 reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/82 8 347.3T8EM: Complete lighting fixture assembly, flush mounting, with one 17-watt T8 cool white fluorescent lamp, clear and white prismatic window assembly, includes emergency battery/ballast circuit for emergency li

20、ghting. DESIGN: Electrical rating: 17 watts, 120 volts, 60 hertz, ungrounded electrical distribution system total input power: 18.0 watts+4.0 watts (battery charging circuit)=22.0 watts total at 120 volts. Dimension and configurations: See figures 1, 2, 3, and 4. Photometric data: See figures 9, 10,

21、 and 11; and tables I, II, and III. Wiring diagram: See figure 8. Ballast: See MIL-DTL-16377/81 for 17-watt T8 lamp specification, MIL-DTL-16377/77 for emergency ballast specification. Mounting dimensions: Symbols 331.1T8 and 347.2T8: Standard mounting (surface), see figure 7. Symbols 331.2T8 and 34

22、7.3T8: Flush mounting (recessed), see figure 6. Window assembly: Symbols 331.1T8 and 331.2T8: White window, see table VI and figure 27 of MIL-DTL-16377. Symbols 347.2T8 and 347.3T8: Prismatic window, see table VI and figure 27 of MIL-DTL-16377. Enclosure: Watertight; see 3.5.11 of MIL-DTL-16377. Cab

23、le: 10 feet (minimum) of type LSFHOF-3 in accordance with MIL-DTL-24643/3. Weight: Symbols 331.1T8EM and 347.2T8EM: Not to exceed 13.5 pounds. Symbols 331.2T8EM and 347.3T8EM: Not to exceed 15 pounds. DESIGNATION AND MARKING: The following labels shall be furnished in accordance with MIL-DTL-16377 a

24、pplied as shown on figures 1 and 5. a. Two Type I labels, equipment identification, reference MIL-DTL-16377 figure 11, shall include manufacturer and address, one located on back and other located on an inner nonreflecting surface. b. One Type II label, circuit wiring information, reference MIL-DTL-

25、16377 figure 12, located on outside surface adjacent to cable entrance. c. Two Type IV label, repair parts, reference MIL-DTL-16377 figure 14, information to be shown shall include “USE THE FOLLOWING REPAIR PARTS ONLY.” List all standard parts shown in table IV, located on an inner nonreflecting sur

26、face and back of fixture. d. One Type IV label, reference MIL-DTL-16377 figure 14, information to be shown shall be “CHARGING INDICATOR LIGHT”. e. One Type IV label, reference MIL-DTL-16377 figure 14, information to be shown shall be “BATTERY ENABLE”. Provided by IHSNot for ResaleNo reproduction or

27、networking permitted without license from IHS-,-,-MIL-DTL-16377/82 9 f. One Type V label, reference MIL-DTL-16377 figure 15, information to be shown shall be “DURING MAINTENANCE, PROTECTIVE DEVICE MUST BE OPENED OR PULLED TO SECURE AC POWER TO THIS FIXTURE AND THE BATTERY ENABLE SWITCH MUST BE IN TH

28、E OFF POSITION.” EXAMINATION AND TESTS: Examinations and tests shall be as specified in MIL-DTL-16377 and the following: First article testing/inspection: Complete fixtures: See table V. Window assemblies: See table VI. Comparison inspection: See tables V and VI. Conformance inspection: See MIL-DTL-

29、16377. Inspection of product for delivery: Examination See MIL-DTL-16377. Conformance test See MIL-DTL-16377. Examination for preparation of delivery See MIL-DTL-16377. GENERAL INFORMATION: Table IV. Fixture standard parts. Table V. Complete fixture first article tests. Table VI. Window assembly fir

30、st article tests. Table VII. Complete fixture part numbers. NOTES: 1. Installation circuit wiring shall incorporate a minimum ratio of eight 17-watt lamps and one emergency 17-watt lamp. The 8-to-1 ratio is required for meeting MIL-STD-1399-300 harmonic requirements. The 17-watt emergency ballast pr

31、oduces non-linear current that must be offset by the linear current from eight 17-watt lamp ballasts connected to the same circuit. 2. Emergency fixtures may be designated as Navy Emergency Automatic Lighting System NEALS. 3. The “battery enable” switch shall be placed in the normal position after i

32、nstallation. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/82 10 TABLE IV. Standard parts. Name Military p/n or specification National Stock Number (NSN) Remarks Lamp Commercial Identification F17T8/CW 6240-01-391-6027 - Lamplock M163

33、77/40-003 - -Lampholder UL Standard 542 6250-00-284-0481 Commercial Ballast M16377/81-001 - Integrated starter type Shockmount M16377/41-008 6210-01-393-4302 0.067 steel, zinc plated Window assembly, diffusing M16377/8-001 6210-00-548-06011/ Window assembly, prismatic M16377/8-003 - 1/ Emergency bal

34、last, wiring harnesses, and mating connector M16377/77-001 6250-01-491-7039 Complete assembly: includes wiring harnesses and matting AMP #206043 connectors. Charging indicator light - 6220-01-415-7889 LED type Switch, battery enable M16377/75-008 5930-01-414-9240 DPST Switch, battery test Carling 21

35、67-M-A-NC-73XCA4 - Momentary toggle Switch cover, rubber boot MIL-DTL-5423/2 - Neoprene Filter, 17-watt T8 fluorescent lamp (DARK ADAPTATION) M16377/42-010 - Red transparent NOTE:1/Window assemblies (diffusing and prismatic) are the same as T12 lamp fixtures (MIL-DTL-16377/8). Provided by IHSNot for

36、 ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/82 11 TABLE V. First article tests and comparison inspection for complete fixtures.1/Test Requirement Test method Remarks Examination 3.13 4.5 - Operation 3. 4.8.1 -Electromagnetic interference 3.6.14 4.8.16 -

37、Electrical equipment interface testing requirements: MIL-STD-1399-300 MIL-STD-1399-300 MIL-STD-1399-300 2/, 3/Dielectric withstanding voltage 3.6.15 4.8.2 4/ Insulation resistance 3.6.16 4.8.3 4/ Enclosure effectiveness 3.5.11 4.8.14.4 4/Shock 3.5.12 4.8.7 4/ Vibration 3.5.13 4.8.8 4/ Enclosure effe

38、ctiveness 3.5.11 4.8.14.4 4/Dielectric withstanding voltage 3.6.15 4.8.2 4/ Insulation resistance 3.6.16 4.8.3 4/ Noise 3.5.14 4.8.9 - Continuity of grounding 3.6.13.4 4.8.12 - Light output 3.7.1 4.8.6.1 - Optical uniformity 3.7.4.1.1 4.8.4 - Stress relief 3.8.5.3 4.8.5 - Magnetic permeability 3.4.8

39、 4.8.18 - Emergency light output: Distribution curves shall be documented during emergency lamp operation 3.7.1 4.8.6.1 5/ Emergency ballast performance: Operating time and discharge test See MIL-DTL-16377/77, Table II, battery discharge test See MIL-DTL-16377/77, Table II, battery discharge test -

40、NOTES:1/Requirements and test methods use MIL-DTL-16377.2/Less, then 1KVA exception not applicable for input waveform THD. 3/Solid state components shall be subject to 250 positive spikes and 250 negative spikes, (500 total spikes), one spike per minute, using testing method identified in MIL-STD-13

41、99-300. 4/Tests shall be performed in the order specified. 5/Shall meet or exceed published distribution curves. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16377/82 12 TABLE VI. First article tests and comparison inspection for window as

42、semblies.1/Test Requirement paragraph Test paragraph Remarks Examination 3.13 4.5 - Optical uniformity 3.7.4.1.1 4.8.4 - Stress relief 3.8.5.3 4.8.5 - Shock 3.5.12 4.8.7 1/ Vibration 3.5.13 4.8.8 1/ Enclosure effectiveness 3.5.11 4.8.14.4 1/Light output 3.7.1 4.8.6.1 Candela distribution NOTES: 1/Te

43、sting requirements and methods use MIL-DTL-16377. 2/Tests shall be performed in the order specified. TABLE VII. Complete fixture part numbers. Name Military p/n Complete fixture, symbol 331.1T8EM M16377/82-331.1T8EM Complete fixture, symbol 331.2T8EM M16377/82-331.2T8EM Complete fixture, symbol 347.

44、2T8EM M16377/82-347.2T8EM Complete fixture, symbol 347.3T8EM M16377/82-347.3T8EM Custodians: Preparing Activity: Army CR4 Navy SH Navy SH (Project 6210-2006-006) Air Force 99 Review Activities: Navy AS, CG Air Force 03 DLA GS2 CIV FAS NOTE: The activities listed above were interested in this documen

45、t as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1