1、AMSC N/A FSC 6145 INCH-POUND MIL-DTL-24640/26A 8 November 2011 SUPERSEDING MIL-DTL-24640/26 9 August 2008 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 TO +105 C, 600 VOLTS, TYPE 5XO This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirem
2、ents for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-24640. Construction, Non-Watertight First - Tin-coated copper conductor, AWG size (see table I). Second - Component wires shall be SAE-AS81044/12, except identification shall be in accordance with t
3、able II. Testing shall be in accordance with the component wire ratings and requirements listed on this specification sheet. Conformance testing procedures shall be in accordance with SAE-AS81044. Third - Five components shall be cabled together. Cabling sequence shall be consecutive. Fillers may be
4、 used as necessary to form a round cable. Fourth - Optional binder tape. Fifth - Braided shield of 34 AWG tin-coated copper. Braid angle of 40 to 50 degrees; minimum coverage of 90 percent. Sixth - Cross-linked polyolefin jacket with a minimum wall thickness of 0.035 inch. Color black. NOTE: Manufac
5、turers identification tape or thread is required (see 3.7.3). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24640/26A 2 TABLE I. Construction details. Military part no. M24640/26 Type groups A, B, C, and D; plus the following: Aging and com
6、patibility (cable) (1255 C) No failure Abrasion resistance (jacket) (scrapes, min.) 75 Acid gas equivalent (percent, max.) Jacket 2 Fillers 2 Insulation 18 Halogen content (percent, max.) Jacket 0.2 Fillers 0.2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from
7、 IHS-,-,-MIL-DTL-24640/26A 5 Smoke index (max.) Jacket 25 Fillers 45Insulation 35 Toxicity index (max.) Jacket 5 Fillers 5 Insulation 1.5 Immersion (jacket) Tensile strength (percent of unaged, min.) 50 Elongation (percent of unaged, min.) 50 Durometer (jacket) - Type A (hardness, min.) 80 Weatherin
8、g (jacket) No failure Fungus resistance No failure Abrasion resistance No failure Gas flame (3 hour) Not applicable Component wire No failure UNIT ORDERING LENGTHS: Type and size Feet (nominal) 5XO-3, 5XO-4, 5XO-6 250 CHANGES FROM PREVIOUS ISSUE: Marginal notations are not used in this revision to i
9、dentify changes with respect to the previous issue due to the extent of the changes. Custodians: Preparing Activity:Army MI Navy SH Navy SH (Project 6145-2009-101) Review Activities: Army AR, AV, CR, CR4 Navy CG, EC NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-