NAVY MIL-DTL-24643 20 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +105 DEGREE C 1000 VOLTS TYPE LS7SGU《LS7SGU型1000 V -20 ℃~+105 ℃电缆》.pdf

上传人:arrownail386 文档编号:978645 上传时间:2019-03-13 格式:PDF 页数:4 大小:30.77KB
下载 相关 举报
NAVY MIL-DTL-24643 20 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +105 DEGREE C 1000 VOLTS TYPE LS7SGU《LS7SGU型1000 V -20 ℃~+105 ℃电缆》.pdf_第1页
第1页 / 共4页
NAVY MIL-DTL-24643 20 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +105 DEGREE C 1000 VOLTS TYPE LS7SGU《LS7SGU型1000 V -20 ℃~+105 ℃电缆》.pdf_第2页
第2页 / 共4页
NAVY MIL-DTL-24643 20 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +105 DEGREE C 1000 VOLTS TYPE LS7SGU《LS7SGU型1000 V -20 ℃~+105 ℃电缆》.pdf_第3页
第3页 / 共4页
NAVY MIL-DTL-24643 20 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +105 DEGREE C 1000 VOLTS TYPE LS7SGU《LS7SGU型1000 V -20 ℃~+105 ℃电缆》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 INCH-POUND MIL-DTL-24643/20F 1 October 2009 SUPERSEDING MIL-DTL-24643/20E 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LS7SGU This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for a

2、cquiring the product described herein shall consist of this specification sheet and MIL-DTL-24643. Construction, Watertight with Circuit Integrity First - Copper conductor, coated or uncoated (see table I for size). Second - Thermoset insulation (see table I for thickness). Third - Optional glass br

3、aid. Fourth - Optional covering (unless required by 3.3.5 of MIL-DTL-24643. Fifth - The seven conductors shall be cabled together with a lay in accordance with 3.4.4 of MIL-DTL-24643. Cabling sequence shall be consecutive, starting with no 1. from the center outward. Standard identification code app

4、lied by Method 1. Sixth - An optional binder. Seventh - Cross-linked polyolefin jacket. Minimum average wall thickness of 0.040 inch. AMSC N/A FSC 6145 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/20F TABLE I. Details. Military part

5、no. M24643/20 Type and size Conductor size AWG Cable overall diameter max. (inch) Insulation thickness min. avg. (inch) Conductor resistance max. (ohms) -01UN LS7SGU-3 16 (Class B) 0.545 0.018 4.3 -02UN LS7SGU-4 14 (Class B) 0.595 0.018 2.68 REQUIREMENTS: Qualification required. INSPECTION: Basic El

6、ectricals: Conductor resistance (ohms/1000 feet at 25 C, max.) See table I Voltage withstand (volts, root mean square, min.) Conductor to conductor 3000 Insulation resistance (megohms/1000 feet, min.) Conductor to conductor 500 Conductor continuity No failure Group A: Visual and dimensional No failu

7、re Abrasion resistance, extruded insulation only (scrapes min.) 250 Watertightness (see MIL-DTL-24643 for limits of water leakage) No failure Crack resistance (extruded insulation only) No damage Group B: Cold bending cable No failure Thermoset proof test (percent, max.) Insulation 50 Jacket (when t

8、ested at 200 C) 50 Drip (951C) ZeroPhysicals (unaged) Insulation (extruded) Tensile strength (lb/in2, min.) 700 Elongation (percent, min.) 150 Jacket (cable) Tensile strength (lb/in2, min.) 1300 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-D

9、TL-24643/20F Elongation (percent, min.) 160 Tear (lb/in thickness, min.) 35 Gas flame (1 hour) No failure Group C: Physicals (aged) air oven Jacket (cable) Tensile strength (percent of unaged, min.) 60 Elongation (percent of unaged, min.) 60 Permanence of printing (cycles, min.) 25 Permanence of pri

10、nting (jacket) (cycles, min.) 125 Heat distortion (percent of unaged, max.) 30 Cable fill (sealant) removability No failure Shrinkage No failure Group D: Flame propagation (cable) No failure Qualification Inspection: Qualification inspection shall include basic electricals; groups A, B, C, and D; pl

11、us the following: Cold working (minus 202 C) No damage Gas flame (3 hours) No failure Aging and compatibility (cable) (1255 C) No failure Abrasion resistance (jacket) (scrapes, min.) 75 Acid gas equivalent (percent, max.) Jacket 2 Fillers 2 Insulation 18Halogen content (percent, max.) Jacket 0.2 Fil

12、lers 0.2Insulation 0.2 Immersion (jacket) Tensile strength (percent of unaged, min.) 50 Elongation (percent of unaged, min.) 50 Smoke index (max.) 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/20F 4 Jacket 25 Fillers 45 Insulation 4

13、5Toxicity index (max.) Jacket 5 Fillers 5Insulation 1.5 Durometer (jacket) - Type A (hardness, min.) 80 Weathering (jacket) No failure Electrical moisture absorption No failure UNIT ORDERING LENGTHS: Type and size Feet (nominal) LS7SGU all sizes 2000 CHANGES FROM PREVIOUS ISSUE: Marginal notations a

14、re not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Custodians: Preparing Activity: Army MI Navy SH Navy SH (Project 6145-2008-024) Review Activities: Army AR, AV, CR Navy CG, EC DLA CC NOTE: The activities listed above were intereste

15、d in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DIN 43627-1992 House connection boxes for underground service for HRC-fuses size 00 up to 100 A 500 V and size 1 up to 250 A 500 V《规格00-100A 500V和规格1-250A 500高遮断容量熔断器用地下输电用户分线箱》.pdf DIN 43627-1992 House connection boxes for underground service for HRC-fuses size 00 up to 100 A 500 V and size 1 up to 250 A 500 V《规格00-100A 500V和规格1-250A 500高遮断容量熔断器用地下输电用户分线箱》.pdf
  • DIN 43627-3-1998 en 7533 House connection boxes for underground service - Flush-type house connection boxes for underground service for HRC-fuses size 00 up to 100 A 500 V and size.pdf DIN 43627-3-1998 en 7533 House connection boxes for underground service - Flush-type house connection boxes for underground service for HRC-fuses size 00 up to 100 A 500 V and size.pdf
  • DIN 43628-1998 Fuseboxes for cable protection fuses《电缆保护熔断器的熔断器盒》.pdf DIN 43628-1998 Fuseboxes for cable protection fuses《电缆保护熔断器的熔断器盒》.pdf
  • DIN 43629-1-1978 Cable distribution cubicle cabinet mounting dimensions《电缆配电箱 箱体 安装尺寸》.pdf DIN 43629-1-1978 Cable distribution cubicle cabinet mounting dimensions《电缆配电箱 箱体 安装尺寸》.pdf
  • DIN 43629-2-1978 Cable distribution cubicle base mounting dimensions《电缆配电箱 底座、安装尺寸》.pdf DIN 43629-2-1978 Cable distribution cubicle base mounting dimensions《电缆配电箱 底座、安装尺寸》.pdf
  • DIN 43629-3-1982 Cable distribution cubicle internal construction mounting dimensions《电缆配电箱 第3部分 内部结构安装尺寸》.pdf DIN 43629-3-1982 Cable distribution cubicle internal construction mounting dimensions《电缆配电箱 第3部分 内部结构安装尺寸》.pdf
  • DIN 43633-1-2011 Centre break disconnector - Part 1 Rated voltage 123 kV - Terminal and mounting dimensions layout《旋转隔离开关 第1部分 额定电压123 kV 端子和安装尺寸 布置图》.pdf DIN 43633-1-2011 Centre break disconnector - Part 1 Rated voltage 123 kV - Terminal and mounting dimensions layout《旋转隔离开关 第1部分 额定电压123 kV 端子和安装尺寸 布置图》.pdf
  • DIN 43633-2-1988 Two-column (centre-break) disconnector rated voltage 245 kV terminal and mounting dimensions layout《双柱式(中间断开)隔离开关 额定电压 245 kV 第2部分 连接终端和安装尺寸配置》.pdf DIN 43633-2-1988 Two-column (centre-break) disconnector rated voltage 245 kV terminal and mounting dimensions layout《双柱式(中间断开)隔离开关 额定电压 245 kV 第2部分 连接终端和安装尺寸配置》.pdf
  • DIN 43636-1992 Overhead-line house connection boxes for HRC-fuses size 00 up to 100 A 500 V《规格为0至100A500V、HRC熔断器用架空线住户连接线接线盒》.pdf DIN 43636-1992 Overhead-line house connection boxes for HRC-fuses size 00 up to 100 A 500 V《规格为0至100A500V、HRC熔断器用架空线住户连接线接线盒》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1