NAVY MIL-DTL-24643 38 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LSECM《LSECM型600 V -20 ℃~+90℃电缆》.pdf

上传人:orderah291 文档编号:978664 上传时间:2019-03-13 格式:PDF 页数:5 大小:29.29KB
下载 相关 举报
NAVY MIL-DTL-24643 38 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LSECM《LSECM型600 V -20 ℃~+90℃电缆》.pdf_第1页
第1页 / 共5页
NAVY MIL-DTL-24643 38 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LSECM《LSECM型600 V -20 ℃~+90℃电缆》.pdf_第2页
第2页 / 共5页
NAVY MIL-DTL-24643 38 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LSECM《LSECM型600 V -20 ℃~+90℃电缆》.pdf_第3页
第3页 / 共5页
NAVY MIL-DTL-24643 38 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LSECM《LSECM型600 V -20 ℃~+90℃电缆》.pdf_第4页
第4页 / 共5页
NAVY MIL-DTL-24643 38 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LSECM《LSECM型600 V -20 ℃~+90℃电缆》.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 INCH-POUND MIL-DTL-24643/38F 1 October 2009 SUPERSEDING MIL-DTL-24643/38E 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, 600 VOLTS, TYPE LSECM This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acqu

2、iring the product described herein shall consist of this specification sheet and MIL-DTL-24643. Construction, Watertight Component 1: 8 shielded pairs First - Copper conductor, tin-coated, in accordance with ASTM B286, 20 AWG 7 strands. Second - Separator may be used at manufacturers option where re

3、quired to provide free-stripping insulation. Third - Thermoset insulation. Nominal wall thickness of 0.023 inch; wall thickness may vary from nominal as necessary, in order for the completed cable to meet the specified electrical requirements. Colored insulation, one white and one black conductor fo

4、r each pair. Fourth - Two conductors (one black and one white) cabled together with a nominal lay of 2.5 inches to form a pair. Fifth - An optional binder. Sixth - Braided shield of 34 or 36 AWG, tin-coated copper. Braid angle of 20 to 40 degrees; minimum coverage of 85 percent. Seventh - Shield ins

5、ulation of two polyester tapes, outer tape sealed. An alternate shield insulation may consist of one polyester tape, plus an extruded jacket of a suitable transparent material, minimum average thickness of the transparent material 0.003 inch. The standard identification code shall be applied by Meth

6、od 2. Component 2: 8 group (seven conductors in each) First - Copper conductor, coated or uncoated, 18 AWG, Class B stranding (7 by 0.0152 inches). Maximum diameter of 0.050 inch. Second - Thermoset insulation. Nominal wall thickness of 0.008 inch. Colored insulation, five black and two white conduc

7、tors for each group. Third - Seven conductors, five black and two white, with the white conductors adjacent in the layer of six, cabled with a lay not greater than 2 inches, to form each group. AMSC N/A FSC 6145 Provided by IHSNot for ResaleNo reproduction or networking permitted without license fro

8、m IHS-,-,-MIL-DTL-24643/38F Fourth - Group covering of two polyester tapes, outer tape sealed. An alternate shield insulation may consist of one polyester tape, plus an extruded jacket of a suitable transparent material, minimum average thickness of the transparent material 0.003 inch. The standard

9、identification code shall be applied by Method 2. Assembly First - Five pairs cabled to form a core. Three pairs and eight groups of seven cabled over the core, with a lay in accordance with 3.4.4 of MIL-DTL-24643. Pair no. 1 through 5 in core; the sequence of the outer layer pair no. 6; groups no.

10、1, 2 and 3: pair no. 7: groups no. 4, 5 and 6: pair no. 8: groups no. 7 and 8. Fillers may be used as necessary to form a firm, well-rounded assembly. Second - An optional binder. Third - Cross-linked polyolefin jacket (see table I for jacket thickness). TABLE I. Details. Overall diameter Military p

11、art no. M24643/38 Type Number of pairs / number of conductors Cable jacket thickness min. avg. (inch) min. (inch) max. (inch) -01UN LSECM 8/56 0.075 1.290 1.370 REQUIREMENTS: Qualification required. INSPECTION: Basic Electricals: Conductor resistance (ohms/1000 feet at 25 C, max.) ASTM B286, Size 20

12、7 11.03 18 AWG, Class B 7.47 Voltage withstand (volts, root mean square, min.) Conductor to conductor 2000 Conductor to shield (pairs only) 1000 Component shield to component shield 500 Insulation resistance (megohms/1000 feet, min.) Conductor to conductor 500 Conductor to shield (pairs only) 500 C

13、omponent shield to component shield 100 Conductor continuity No failure Shield continuity No failure 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/38F Group A: Visual and dimensional No failure Watertightness (see MIL-DTL-24643 for

14、limits of water leakage) No failure Capacitance (pairs only) Mutual capacitance, 1 kilohertz (KHz) (pF/ft, max.) 30 Group B: Thermoset proof test (percent, max.) Insulation 50 Jacket (when tested at 200 C) 50 Physicals (unaged) Insulation (extruded) Tensile strength (lb/in2, min.) 700 Elongation (pe

15、rcent, min.) 150 Jacket (cable) Tensile strength (lb/in2, min.) 1300 Elongation (percent, min.) 160 Tear (lb/in thickness, min.) 35 Drip (951 C) Zero Group C: Physicals (aged) air oven Insulation (extruded) Tensile strength (percent of unaged, min.) 75 Elongation (percent of unaged, min.) 75 Jacket

16、cable) Tensile strength (percent of unaged, min.) 60 Elongation (percent of unaged, min.) 60 Permanence of printing (jacket) (cycles, min.) 125 Heat distortion (percent of unaged, max.) 30 Shrinkage No failure Cable sealant removability No failure Shield (conformance to material, construction and c

17、overage) No failure Group D: Flame propagation (cable) No failure 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/38F Qualification Inspection: Qualification inspection shall include basic electricals; groups A, B, C, and D; plus the

18、following: Aging and compatibility (cable) (1255 C) No failure Abrasion resistance (jacket) (scrapes, min.) 75 Acid gas equivalent (percent, max.) Jacket 2 Fillers 2 Insulation 18Shield insulation /group covering 2 Halogen content (percent, max.) Jacket 0.2 Fillers 0.2Insulation 0.2Immersion (jacket

19、) Tensile strength (percent of unaged, min.) 50 Elongation (percent of unaged, min.) 50 Smoke index (max.) Jacket 25 Fillers 45Insulation 45 Toxicity index (max.) Jacket 5 Fillers 5Insulation 1.5Durometer (jacket) - Type A (hardness, min.) 80 Weathering (jacket) No failure Electrical moisture absorp

20、tion No failure UNIT ORDERING LENGTHS: Type Feet (nominal) LSECM 1000 CHANGES FROM PREVIOUS ISSUE: Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. 4 Provided by IHSNot for ResaleNo reproduction or networking pe

21、rmitted without license from IHS-,-,-MIL-DTL-24643/38F 5 Custodians: Preparing Activity: Army MI Navy SH Navy SH (Project 6145-2008-042) Review Activities: Army AR, AV, CR Navy CG, EC DLA CC NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ETSI PRETS 300 146-1991 Integrated Services Digital Network (ISDN) and Other Digital Telecommunications Networks Audiovisual Teleservices Frame Synchronous Control and Indication S业.pdf ETSI PRETS 300 146-1991 Integrated Services Digital Network (ISDN) and Other Digital Telecommunications Networks Audiovisual Teleservices Frame Synchronous Control and Indication S业.pdf
  • ETSI PRETS 300 148-1991 Terminal Equipment (TE) Requirements for Teletex Systems Participating in the Service (T TE 07-10)《终端设备(TE) 对业务中使用的电传系统的要求(T TE07-10)》.pdf ETSI PRETS 300 148-1991 Terminal Equipment (TE) Requirements for Teletex Systems Participating in the Service (T TE 07-10)《终端设备(TE) 对业务中使用的电传系统的要求(T TE07-10)》.pdf
  • ETSI PRETS 300 169-1991 Data Link Layer Protocol for the D-Channel of the Interfaces at the Reference Point between Terminal Equipment and Private Telecommunications Networks《在终端设备.pdf ETSI PRETS 300 169-1991 Data Link Layer Protocol for the D-Channel of the Interfaces at the Reference Point between Terminal Equipment and Private Telecommunications Networks《在终端设备.pdf
  • ETSI PRETS 300 169-1991 Data Link Layer Protocol for the D-Channel of the Interfaces at the Reference Point between Terminal Equipment and Private Telecommunications Networks《在终端设备_1.pdf ETSI PRETS 300 169-1991 Data Link Layer Protocol for the D-Channel of the Interfaces at the Reference Point between Terminal Equipment and Private Telecommunications Networks《在终端设备_1.pdf
  • ETSI PRETS 300 170-1991 Data Link Layer Protocol at the Q Reference Point for the Signalling Channel between Two Private Telecommunication Network Exchanges《用于两专用通信网络交换的信令信道在Q参考点上的.pdf ETSI PRETS 300 170-1991 Data Link Layer Protocol at the Q Reference Point for the Signalling Channel between Two Private Telecommunication Network Exchanges《用于两专用通信网络交换的信令信道在Q参考点上的.pdf
  • ETSI PRETS 300 170-1991 Data Link Layer Protocol at the Q Reference Point for the Signalling Channel between Two Private Telecommunication Network Exchanges《用于两专用通信网络交换的信令信道在Q参考点上的_1.pdf ETSI PRETS 300 170-1991 Data Link Layer Protocol at the Q Reference Point for the Signalling Channel between Two Private Telecommunication Network Exchanges《用于两专用通信网络交换的信令信道在Q参考点上的_1.pdf
  • ETSI PRETS 300 175-7-1997 Digital Enhanced Cordless Telecommunications (DECT) Common Interface (CI) Part 7 Security Features (Third Edition)《数字增强无绳通信(DECT) 公用接口(CI) 第7部分 安全特性(第3版)》.pdf ETSI PRETS 300 175-7-1997 Digital Enhanced Cordless Telecommunications (DECT) Common Interface (CI) Part 7 Security Features (Third Edition)《数字增强无绳通信(DECT) 公用接口(CI) 第7部分 安全特性(第3版)》.pdf
  • ETSI PRETS 300 193-1991 Satellite Earth Stations (SES) General Requirements for the Connection of Very Small Aperture Terminal (VSAT) Systems to Terrestrial Networks《卫星地面站(SES) 甚小孔.pdf ETSI PRETS 300 193-1991 Satellite Earth Stations (SES) General Requirements for the Connection of Very Small Aperture Terminal (VSAT) Systems to Terrestrial Networks《卫星地面站(SES) 甚小孔.pdf
  • ETSI PRETS 300 193-1991 Satellite Earth Stations (SES) General Requirements for the Connection of Very Small Aperture Terminal (VSAT) Systems to Terrestrial Networks《卫星地面站(SES) 甚小孔_1.pdf ETSI PRETS 300 193-1991 Satellite Earth Stations (SES) General Requirements for the Connection of Very Small Aperture Terminal (VSAT) Systems to Terrestrial Networks《卫星地面站(SES) 甚小孔_1.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1