NAVY MIL-DTL-24643 5 G-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LSMDU《LSMDU型600 V -20 ℃~+90 ℃电缆》.pdf

上传人:roleaisle130 文档编号:978677 上传时间:2019-03-13 格式:PDF 页数:4 大小:27.10KB
下载 相关 举报
NAVY MIL-DTL-24643 5 G-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LSMDU《LSMDU型600 V -20 ℃~+90 ℃电缆》.pdf_第1页
第1页 / 共4页
NAVY MIL-DTL-24643 5 G-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LSMDU《LSMDU型600 V -20 ℃~+90 ℃电缆》.pdf_第2页
第2页 / 共4页
NAVY MIL-DTL-24643 5 G-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LSMDU《LSMDU型600 V -20 ℃~+90 ℃电缆》.pdf_第3页
第3页 / 共4页
NAVY MIL-DTL-24643 5 G-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LSMDU《LSMDU型600 V -20 ℃~+90 ℃电缆》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 INCH-POUND MIL-DTL-24643/5G 1 October 2009 SUPERSEDING MIL-DTL-24643/5F 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, 600 VOLTS, TYPE LSMDU This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquir

2、ing the product described herein shall consist of this specification sheet and MIL-DTL-24643. Construction, Watertight First - Copper conductor, coated or uncoated (see table I for size). Second - Separator may be used at manufacturers option where required to provide free-stripping insulation. Thir

3、d - Thermoset insulation (see table I for wall thickness). Standard identification code applied by Method 1 or Method 3. If identification Method 1 is used, insulation color shall be black. Fourth - Nineteen conductors cabled together in accordance with 3.4.4 of MIL-DTL-24643. Cabling sequence to be

4、 consecutive, starting with no. 1 from the center outward. Fillers may be used as necessary to form a firm well-rounded assembly. Fifth - An optional binder. Sixth - Cross-linked polyolefin jacket (see table I for thickness). AMSC N/A FSC 6145 Provided by IHSNot for ResaleNo reproduction or networki

5、ng permitted without license from IHS-,-,-MIL-DTL-24643/5G TABLE I. Details. Military part no. M24643/5 Type and size Conductor AWG size Insulation thickness min. avg. (inch) Cable jacket thickness min. avg. (inch) Overall diameter max. (inch) Conductor resistance (ohms) Insulation resistance (megoh

6、ms) -01UN LSMDU-6 12 (Class B) 0.028 0.060 1.000 1.730 100 -02UN LSMDU-14 9 (Class B) 0.040 0.060 1.395 0.868 100 -03UN LSMDU-23 7 (Class B) 0.052 0.075 1.765 0.598 100 -04UN LSMDU-40 4 (Class C) 0.052 0.075 2.040 0.273 90 -05UN LSMDU-60 2 (Class D) 0.052 0.075 2.330 0.172 75 REQUIREMENTS: Qualifica

7、tion required. INSPECTION: Basic Electricals: Conductor resistance (ohms/1000 feet at 25 C, max.) See table I Voltage withstand (volts, root mean square, min.) Conductor to conductor 2500 Insulation resistance (megohms/1000 feet, min.) Conductor to conductor See table I Conductor continuity No failu

8、re Group A: Visual and dimensional No failure Watertightness (see MIL-DTL-24643 for limits of water leakage) No failure Group B: Cold bending cable No failure Thermoset proof test (percent, max.) Insulation 50 Jacket (when tested at 200 C) 50 Drip (951 C) Zero Physicals (unaged) Insulation (extruded

9、) Tensile strength (lb/in2, min.) 700 Elongation (percent, min.) 150 Jacket (cable) 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/5G Tensile strength (lb/in2, min.) 1300 Elongation (percent, min.) 160 Tear (lb/in thickness, min.) 35

10、 Group C: Physicals (aged) air oven Insulation (extruded) Tensile strength (percent of unaged, min.) 75 Elongation (percent of unaged, min.) 75 Jacket (cable) Tensile strength (percent of unaged, min.) 60 Elongation (percent of unaged, min.) 60 Permanence of printing (insulation, Method 1 only) (cyc

11、les, min.) 25 Permanence of printing (jacket) (cycles, min.) 125 Heat distortion (percent of unaged, max.) 30 Cable fill (sealant) removability No failure Shrinkage No failure Group D: Flame propagation (cable) No failure Qualification Inspection: Qualification inspection shall include basic electri

12、cals; groups A, B, C, and D; plus the following: Aging and compatibility (cable) (1255 C) No failure Abrasion resistance (jacket) (scrapes, min.) 75 Jacket 2 Fillers 2Insulation 18 Halogen content (percent, max.) Jacket 0.2 Fillers 0.2Insulation 0.2Immersion (jacket) Tensile strength (percent of una

13、ged, min.) 50 Elongation (percent of unaged, min.) 50 Smoke index (max.) 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/5G 4 Jacket 25 Fillers 45 Insulation 45Toxicity index (max.) Jacket 5 Fillers 5Insulation 1.5 Durometer (jacket)

14、- Type A (hardness, min.) 80 Weathering (jacket) No failure Electrical moisture absorption No failure UNIT ORDERING LENGTHS: Type and size Feet (nominal) LSMDU- 6, 14 and 23 1000 LSMDU- 40 and 60 500 CHANGES FROM PREVIOUS ISSUE: Marginal notations are not used in this revision to identify changes wi

15、th respect to the previous issue due to the extent of the changes. Custodians: Preparing Activity: Army MI Navy SH Navy SH (Project 6145-2008-010) Review Activities: Army AR, AV, CR Navy CG, EC DLA CC NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1