NAVY MIL-DTL-24643 66 A-2010 CABLE ELECTRICAL 1000 VOLTS TYPE LS2OW《LS2OW型1000 V电缆》.pdf

上传人:tireattitude366 文档编号:978693 上传时间:2019-03-13 格式:PDF 页数:5 大小:29.75KB
下载 相关 举报
NAVY MIL-DTL-24643 66 A-2010 CABLE ELECTRICAL 1000 VOLTS TYPE LS2OW《LS2OW型1000 V电缆》.pdf_第1页
第1页 / 共5页
NAVY MIL-DTL-24643 66 A-2010 CABLE ELECTRICAL 1000 VOLTS TYPE LS2OW《LS2OW型1000 V电缆》.pdf_第2页
第2页 / 共5页
NAVY MIL-DTL-24643 66 A-2010 CABLE ELECTRICAL 1000 VOLTS TYPE LS2OW《LS2OW型1000 V电缆》.pdf_第3页
第3页 / 共5页
NAVY MIL-DTL-24643 66 A-2010 CABLE ELECTRICAL 1000 VOLTS TYPE LS2OW《LS2OW型1000 V电缆》.pdf_第4页
第4页 / 共5页
NAVY MIL-DTL-24643 66 A-2010 CABLE ELECTRICAL 1000 VOLTS TYPE LS2OW《LS2OW型1000 V电缆》.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 INCH-POUND MIL-DTL-24643/66A 28 January 2010 SUPERSEDING MIL-DTL-24643/66 7 November 2007 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, 1000 VOLTS, TYPE LS2OW This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the prod

2、uct described herein shall consist of this specification sheet and MIL-DTL-24643. Construction (Watertight with Circuit Integrity) First - Copper conductor, coated or uncoated (see table I for size). Second - Thermoset insulation, extruded or taped (see table I for minimum average wall). Third - Opt

3、ional glass braid. Fourth - Optional covering, unless required (see 3.3.5 of MIL-DTL-24643). Fifth - Two conductors shall be cabled together to form a firm, well-rounded assembly with a lay not less than 8 or greater than 16 times the cabled diameter. Standard identification code applied by Method 1

4、 3, or 5. Fillers may be used as necessary to form a firm well-rounded assembly. Sixth - Aluminum foil/polyester tape/aluminum foil. 0.002-inch thick with 45 percent overlap. Seventh - Braided shield of tin-coated copper. AWG and coverage as necessary to comply with shield performance requirements.

5、 Eighth - An optional binder. Ninth - Cross-linked polyolefin jacket (see table I for wall thickness). AMSC N/A FSC 6145 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/66A TABLE I. Details. Overall diameter (inches) Military part no. M

6、24643/66 (type) Conductors size (AWG) Insulation resistance (megohms) Insulation wall thickness min. avg. (inches) Jacket wall thickness min. avg. (inches) Min. Max. Conductor resistance per 1000 feet at 25 C (ohms) -01UO (LS2OW-3) 16 (Class B) 500 0.018 0.027 0.345 0.370 4.3 -02UO (LS2OW-4) 14 (Cla

7、ss B) 500 0.018 0.028 0.366 0.392 2.68 -03UO (LS2OW-9) 10 (Class B) 500 0.018 0.036 0.466 0.499 1.08 -04UO (LS2OW-14) 9 (Class B) 500 0.025 0.040 0.639 0.686 0.859 -05UO (LS2OW-23) 7 (Class B) 500 0.025 0.050 0.743 0.797 0.543 -06UO (LS2OW-50) 3 (Class C) 200 0.035 0.050 0.894 0.959 0.21 -07UO (LS2O

8、W-75) 1 (Class C) 175 0.035 0.050 1.033 1.108 0.134 -08UO (LS2OW-100) 0 (Class D) 160 0.035 0.060 1.149 1.232 0.106 -09UO (LS2OW-200) 0000 (Class D) 125 0.050 0.060 1.519 1.630 0.053 REQUIREMENTS: Qualification Required. INSPECTION: Basic Electricals: Conductor resistance (ohms/1000 feet at 25 C, ma

9、x.) See table I Voltage withstand (volts, root mean square, min.) Conductor to conductor (sizes 3 9) 3000 Conductor to conductor (sizes 14 200) 5000 Conductor to shield (sizes 3 9) 1500 Conductor to shield (sizes 14 200) 2500 Insulation resistance (megohms/1000 feet, min.) Sizes 3 200 See table I Co

10、nductor and shield continuity No failure Jacket flaws No failure 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/66A Group A: Visual and dimensional No failure Watertightness (see MIL-DTL-24643 for limits of water leakage) No failure

11、Crack resistance No damage (applicable to constructions using glass braids with coverings) Group B: Thermoset proof test (percent, max.) Insulation (extruded insulations only) 50 Jacket (when tested at 200 C) 50 Drip (951 C) Zero Cold bending (cable) No damage Gas flame (1 hour) No failure Physicals

12、 (unaged) Insulation (extruded insulations only) Tensile strength (lb/in2, min.) 700 Elongation (percent, min.) 150 Jacket (cable) Tensile strength (lb/in2, min.) 1300 Elongation (percent, min.) 160 Tear (lb/in thickness, min.) 35 Group C: Physicals (aged) (air oven) Jacket (cable) Tensile strength

13、percent of unaged, min.) 60 Elongation (percent of unaged, min.) 60 Shrinkage No failure Heat distortion (percent of unaged, max.) 30 Permanence of printing (conductor Method 1 only) 25 (cycles, min.) Permanence of printing (jacket) (cycles, min.) 125 Cable sealant removability No failure Surface t

14、ransfer impedance Milliohms per meter, max. 700 EMP, response (db, min.) 60 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/66A Group D: Flame propagation (cable) No failure Qualification Inspection: Qualification inspection shall inc

15、lude basic electricals; groups A, B, C, and D; plus the following: Gas flame (3 hours) No failure Aging and compatibility (cable) (1255 C) No failure Abrasion resistance Jacket (75 scraps, min.) No damage Insulation (extruded insulation only, 250 scraps, min.) No damage Acid gas equivalent (percent,

16、 max.) Jacket 2 Fillers 2Insulation 18Halogen content (percent, max.) Jacket 0.2 Fillers 0.2 Insulation 0.2Immersion (jacket) Tensile strength (percent of unaged, min.) 50 Elongation (percent of unaged, min.) 50 Smoke index, max. Jacket 25 Fillers 45Insulation 35 Toxicity index, max. Jacket 5 Filler

17、s 5Insulation 1.5Durometer (jacket) Type A (hardness, min.) 80 Weathering (jacket) No failure UNIT ORDERING LENGTHS: Type and size Feet (nominal) LS2OW 500 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/66A 5 CHANGES FROM PREVIOUS IS

18、SUE: Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Custodians: Preparing Activity: Army MI Navy SH Navy SH (Project 6145-2009-109) Review Activities: Army AR, AV, CR Navy CG, EC DLA CC NOTE: The activities li

19、sted above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS PD 970-2005 Wrought steels for mechanical and allied engineering purposes - Requirements for carbon carbon manganese and alloy hot worked or cold finished steels《机械及相关工程用途用锻钢 碳、.pdf BS PD 970-2005 Wrought steels for mechanical and allied engineering purposes - Requirements for carbon carbon manganese and alloy hot worked or cold finished steels《机械及相关工程用途用锻钢 碳、.pdf
  • BS PD CEN ISO TR 22007-5-2014 Plastics Determination of thermal conductivity and thermal diffusivity Results of interlaboratory testing of poly(methyl methacrylate) samples《塑料 热导率和.pdf BS PD CEN ISO TR 22007-5-2014 Plastics Determination of thermal conductivity and thermal diffusivity Results of interlaboratory testing of poly(methyl methacrylate) samples《塑料 热导率和.pdf
  • BS PD CEN ISO TR 52000-2-2017 Energy performance of buildings Overarching EPB assessment Explanation and justification of ISO 52000-1《建筑物能源性能 首要EPB评定 第2部分 ISO 52000-1的解释和理由》.pdf BS PD CEN ISO TR 52000-2-2017 Energy performance of buildings Overarching EPB assessment Explanation and justification of ISO 52000-1《建筑物能源性能 首要EPB评定 第2部分 ISO 52000-1的解释和理由》.pdf
  • BS PD CEN ISO TR 52003-2-2017 Energy performance of buildings Indicators requirements ratings and certificates Explanation and justification of ISO 52003-1《建筑物能源性能 指标 要求 评级和证书 第2部分.pdf BS PD CEN ISO TR 52003-2-2017 Energy performance of buildings Indicators requirements ratings and certificates Explanation and justification of ISO 52003-1《建筑物能源性能 指标 要求 评级和证书 第2部分.pdf
  • BS PD CEN ISO TR 6579-3-2014 Microbiology of the food chain Horizontal method for the detection enumeration and serotyping of Salmonella Guidelines for serotyping of Salmonella spp.pdf BS PD CEN ISO TR 6579-3-2014 Microbiology of the food chain Horizontal method for the detection enumeration and serotyping of Salmonella Guidelines for serotyping of Salmonella spp.pdf
  • BS PD CEN ISO TS 14265-2013 Health Informatics Classification of purposes for processing personal health information《健康信息学 处理个人健康信息的目的分类》.pdf BS PD CEN ISO TS 14265-2013 Health Informatics Classification of purposes for processing personal health information《健康信息学 处理个人健康信息的目的分类》.pdf
  • BS PD CEN ISO TS 14907-2-2016 Electronic fee collection Test procedures for user and fixed equipment Conformance test for the on-board unit application interface《电子收费 用户及固定设备的试验规程 .pdf BS PD CEN ISO TS 14907-2-2016 Electronic fee collection Test procedures for user and fixed equipment Conformance test for the on-board unit application interface《电子收费 用户及固定设备的试验规程 .pdf
  • BS PD CEN ISO TS 16558-2-2015 Soil quality Risk-based petroleum hydrocarbons Determination of aliphatic and aromatic fractions of semi-volatile petroleum hydrocarbons using gas chrF.pdf BS PD CEN ISO TS 16558-2-2015 Soil quality Risk-based petroleum hydrocarbons Determination of aliphatic and aromatic fractions of semi-volatile petroleum hydrocarbons using gas chrF.pdf
  • BS PD CEN ISO TS 16775-2014 Packaging for terminally sterilized medical devices Guidance on the application of ISO 11607-1 and ISO 11607-2《终端无菌医疗器械的包装 ISO 11607-1和ISO 11607-2应用指南》.pdf BS PD CEN ISO TS 16775-2014 Packaging for terminally sterilized medical devices Guidance on the application of ISO 11607-1 and ISO 11607-2《终端无菌医疗器械的包装 ISO 11607-1和ISO 11607-2应用指南》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1