NAVY MIL-DTL-32149 A-2007 CLOTH WATERPROOF FLAME RESISTANT MOISTURE VAPOR PERMEABLE《防水阻燃利于水分渗透衣》.pdf

上传人:赵齐羽 文档编号:978804 上传时间:2019-03-13 格式:PDF 页数:20 大小:144.22KB
下载 相关 举报
NAVY MIL-DTL-32149 A-2007 CLOTH WATERPROOF FLAME RESISTANT MOISTURE VAPOR PERMEABLE《防水阻燃利于水分渗透衣》.pdf_第1页
第1页 / 共20页
NAVY MIL-DTL-32149 A-2007 CLOTH WATERPROOF FLAME RESISTANT MOISTURE VAPOR PERMEABLE《防水阻燃利于水分渗透衣》.pdf_第2页
第2页 / 共20页
NAVY MIL-DTL-32149 A-2007 CLOTH WATERPROOF FLAME RESISTANT MOISTURE VAPOR PERMEABLE《防水阻燃利于水分渗透衣》.pdf_第3页
第3页 / 共20页
NAVY MIL-DTL-32149 A-2007 CLOTH WATERPROOF FLAME RESISTANT MOISTURE VAPOR PERMEABLE《防水阻燃利于水分渗透衣》.pdf_第4页
第4页 / 共20页
NAVY MIL-DTL-32149 A-2007 CLOTH WATERPROOF FLAME RESISTANT MOISTURE VAPOR PERMEABLE《防水阻燃利于水分渗透衣》.pdf_第5页
第5页 / 共20页
点击查看更多>>
资源描述

1、NOT MEASUREMENTSENSITIVE MIL-DTL-32149A 30 January 2007 SUPERSEDING MIL-DTL-32149 28 April 2004 DETAIL SPECIFICATION CLOTH, WATERPROOF, FLAME RESISTANT, MOISTURE VAPOR PERMEABLE This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1. Scope. Th

2、is document covers flame resistant, waterproof, and moisture vapor permeable cloth used in the ruggedized flyers coveralls. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited

3、 in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3 and 4 of this spec

4、ification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications. The following specification forms a part of this document to the extent specified herein. Unless otherwise specified, the issue of this document is that cited in the solicitation or contract. Comments, suggest

5、ions, or questions on this document should be addressed to: Commander, Naval Air Warfare Center Aircraft Division (Code 491000B120-3), Highway 547, Lakehurst, NJ 08733-5100 or emailed to thomas.omaranavy.mil. Since contact information can change, you may want to verify the currency of this address i

6、nformation using the ASSIST Online database at http:/assist.daps.dla.mil. AMSC N/A FSC 8305 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-32149A DEPARTMENT OF DEFENSE SPECIFICATION MIL-DTL-83133 - Turbine Fuels, Aviation, Kerosene Types, NA

7、TO F-34 (JP-8), NATO F-35, and JP-8+100 (Copies of this document are available online at http:/assist.daps.dla.mil/quicksearch/ or http:/assist.daps.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2.2 Other Government document

8、s and drawings. The following other Government documents and drawing form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. CODE OF FEDERAL REGULATION 27 CFR 21 - Formulas for Denatured A

9、lcohol and Rum (Copies of this document are available online at www.gpoaccess.gov/cfr/about.html or from the Superintendent of Documents, U.S. Government Printing Office, North Capital WVP in g(Pa*m2*h) WVPapp = water vapor permeability apparatus4.4.7 Colorfastness. 4.4.7.1 Laundering. Laundering sh

10、all be tested as specified in AATCC Test Method 61, Test 1A, 3 cycles. 1993 AATCC Standard Reference Detergent WOB (without fluorescent whitening agent and without phosphate) shall be used. 4.4.8 Synthetic perspiration test. The specimen, 8 by 8 inches, shall be cut and exposed to synthetic perspira

11、tion as follows: The synthetic perspiration solution shall be made by combining 3.0 grams sodium chloride, 1.0 gram trypticase soy broth powder, 1.0 gram normal propyl propionate, 0.5 gram of liquid lecithin and 500 ml of distilled water. Cover the solution and heat to 50 C, stirring frequently whil

12、e heating. Continue until all ingredients are dissolved. Then, cool the solution to 35 C, remove cover and dispense it immediately with a pipette or other measuring device. Dispense 2 ml of perspiration solution at 35 C onto the center of an 8- by 8- by 1/4 inch glass plate. Place the specimen on th

13、e glass plate with the back side contacting the glass. Dispense an additional 2 ml of the synthetic perspiration solution onto the center of the 15 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-32149A specimen. Place a second 8- by 8- by 1/

14、4-inch glass plate on top of the specimen and then place a 4 pound weight on top of the assembly in the center. After 16 hours, remove the specimen (do not rinse) and air dry the specimen before testing as specified in AATCC Test Method 15. 4.4.9 Contamination procedure. The specimen (or specimen ar

15、ea) shall be laid flat, face side up, on a glass plate. Three drops (1ml for sealed samples) of a test liquid, either hydraulic fluid or JP-8 conforming to MIL-DTL-83133, shall be applied to the center of the specimen (or specimen area). A glass plate of the same dimensions shall be placed on the sp

16、ecimen (or specimen area) and a pressure of 0.0625 pounds per square inch (1 pound per square inch for seam sealed samples) of glass plate contact area shall be applied to the assembly. After 16 hours (2 hours for seam sealed samples), remove the specimen (or specimen area) from the assembly and tes

17、t immediately for the required performance property in the center of specimen (or specimen area). For testing the initial condition, the test specimen shall be as specified by the applicable test method. For testing hydrostatic resistance and leakage after laundering, one laundering sample 48 inches

18、 by the full width of the cloth shall be used for each test liquid specified above. Three drops of the test liquid shall be applied to each laundering sample. The face side of the laundering sample shall be marked using a laundry marker pen. The laundering test shall then be conducted in accordance

19、with 4.4.10 for one laundering and drying cycle. After laundering, the specimen areas may be cut from the laundering sample to facilitate performance property testing. Ten specimens shall be tested for each of the initial and the after laundering conditions. 4.4.9.1 Contamination procedure after air

20、craft fluids. The specimen (or specimen area) shall be laid flat, face side up, on a glass plate. One milliliter of JP-8 fuel conforming to MIL-DTL-83133 shall be spread over the middle of the sample, followed by 1 ml of de-icing fluid conforming to SAE-AMS1424. The samples shall then be placed flat

21、 in an air-circulating oven at 50 C for 30 minutes. Remove immediately and test as specified in table IV. 4.4.10 Laundering procedure. Place 2 + 0.2 pounds of the cloth in an automatic washing machine set on permanent press cycle, high water level, and a wash temperature of 100 F. The tolerance for

22、the warm wash temperature shall be +10 F and -0 F. A ballast may be added to equal 2 pounds of cloth. Place 0.5 ounce (14 grams) of AATCC Test Method 135, Standard Reference Detergent (non-phosphate) without optical brighteners into the washer. The duration of each laundering cycle shall be 30 + 5 m

23、inutes. After laundering, place sample and ballast in an automatic tumble dryer set on permanent press cycle that has a temperature of 155 + 5 F, and dry for 30 minutes or until dry. The washer and dryer shall be in accordance with AATCC Test Method 135. 4.4.11 Spectral reflectance. Spectral reflect

24、ance shall be determined on the face side and shall be obtained from 600 to 860 nanometers (nm) at 20 nm intervals on a spectrophotometer (see 6.5) relative to the barium sulfate standard, the preferred white standard. Other white reference materials may be used. If other white reference materials a

25、re used, they shall be calibrated to absolute white, e.g. magnesium oxide or vitrolite tiles (see 6.6). The spectral band width shall be less than 26 nm at 860 nm. Reflectance measurements shall be made by either the monochromatic or polychromatic mode of operation. When the polychromatic mode is us

26、ed, the 16 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-32149A spectrophotometer shall operate with the specimen diffusely illuminated with the full emission of a source that simulates either CIE source A or CIE source D65. The specimen sh

27、all be measured as a single layer, backed with six layers of the same fabric and shade. Measurements shall be taken on a minimum of two different areas and averaged. The measured areas shall be at least 6 inches away from the selvage. The specimen shall be viewed at an angle no greater than 10 degre

28、es from the normal, with the specular component included. Photometric accuracy of the spectrophotometer shall be within 1 percent and wavelength accuracy within 2 nm. Spectral reflectance values obtained shall meet the requirements specified in 3.11. 4.4.12 Toxicity. The cloth shall be tested in acc

29、ordance with Environmental Protection Agency Health Effects Test Guidelines OPPTS 870.2500 Acute Dermal Irritation, and OPPTS 870.2600 Skin Sensitization. 5. PACKAGING 5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified in the contract or order (see 6.2). When a

30、ctual packaging of materiel is to be performed by DoD or in-house contractor personnel, these personnel need to contact the responsible packaging activity to ascertain packaging requirements. Packaging requirements are maintained by Inventory Control Points packaging activities within the Military S

31、ervice or Defense Agency, or within the military services system commands. Packaging data retrieval is available from the managing Military Departments or Defense Agencys automated packaging files, CD-ROM products, or by contacting the responsible packaging activity. 6. NOTES (This section contains

32、information of a general or explanatory nature that may be helpful, but is not mandatory.) 6.1 Intended use. The cloth is military unique based on its use in the fabrication of the continuous wear coverall and components which are worn during overwater flights to protect the aircrew member from hypo

33、thermia in the event of immersion in cold water. 6.2 Acquisition requirements. Acquisition documents should specify the following: a. Title, number and date of this specification. b. Quantity required. c. If first article is required (see 3.1). d. If combination synthetic perspiration test is requir

34、ed prior to moisture vapor transmission rate test (see 3.3). e. Packaging requirements (see 5.1). 6.3 Standard sample. For access to information such as patterns, drawings, standard samples, etc. visit DSCPs Warfighter website, http:/warfighter.dla.mil. Choose Vendor InfoSpecification/Pattern Reques

35、t. Complete the request form and then submit form. 17 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-32149A 6.4 Defect replica kits. Fabric defect replica kits are available from J. Graf (Fabric Defect Kits); Department 817 HG, FC568B, Sears

36、 Roebuck and Company, 3333 Beverly Rd., Hoffman Estates, IL 60179, Phone 847-286-8952, Fax 847-286-5991. 6.5 Spectrophotometer. Suitable spectrophotometers for measuring spectral reflectance in the visible/near spectral include the Data Color CS-5, Diano Hardy, Diano Match Scan, Hunter D54P-IR, and

37、the MacBeth 1500 with IR options. 6.6 White standard. Barium sulfate which may be used as a white reference standard is available from the Eastman Kodak Company. The same source has available magnesium reagent (ribbon). Acceptable tiles can be obtained from the National Institute of Standards and Te

38、chnology or the spectrophotometer manufacturer. 6.7 Insect repellent. DEET insect repellent conforming to Type II, Concentration A of O-I-503 has been used successfully as a reagent in testing. A similar product that contains a 75 percent concentration of DEET can be used. 6.8 Subject term (key word

39、) listing. Coverall Diethyltoluamide Nomex Physical surface appearance Polytetrafluoroethylene 6.9 Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. 18 Provided by IHSNot for ResaleNo

40、 reproduction or networking permitted without license from IHS-,-,-MIL-DTL-32149A Nomex Jersey Knit 1.8 oz/sq. yard FIGURE 1. Film composition. 19 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-32149A CONCLUDING MATERIAL Custodians: Preparin

41、g activity: Navy-AS Navy - AS DLA-CT (Project 8305-2006-011) Review activity: Navy-NU NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using ASSIST Online database at http:/assist.daps.dla.mil. 20 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-