NAVY MIL-DTL-7793 15 A-2012 METER TIME TOTALIZING MINIATURE DIGITAL 115 VAC 50 TO 2400 Hz SQUARE.pdf

上传人:hopesteam270 文档编号:978870 上传时间:2019-03-13 格式:PDF 页数:5 大小:77.22KB
下载 相关 举报
NAVY MIL-DTL-7793 15 A-2012 METER TIME TOTALIZING MINIATURE DIGITAL 115 VAC 50 TO 2400 Hz SQUARE.pdf_第1页
第1页 / 共5页
NAVY MIL-DTL-7793 15 A-2012 METER TIME TOTALIZING MINIATURE DIGITAL 115 VAC 50 TO 2400 Hz SQUARE.pdf_第2页
第2页 / 共5页
NAVY MIL-DTL-7793 15 A-2012 METER TIME TOTALIZING MINIATURE DIGITAL 115 VAC 50 TO 2400 Hz SQUARE.pdf_第3页
第3页 / 共5页
NAVY MIL-DTL-7793 15 A-2012 METER TIME TOTALIZING MINIATURE DIGITAL 115 VAC 50 TO 2400 Hz SQUARE.pdf_第4页
第4页 / 共5页
NAVY MIL-DTL-7793 15 A-2012 METER TIME TOTALIZING MINIATURE DIGITAL 115 VAC 50 TO 2400 Hz SQUARE.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、AMSC N/A FSC 6645 INCH-POUND MIL-DTL-7793/15A 19 October 2012 SUPERSEDING MIL-M-7793/15 15 December 1988 DETAIL SPECIFICATION SHEET METER, TIME TOTALIZING, MINIATURE, DIGITAL, 115 VAC, 50 TO 2400 Hz, SQUARE This specification is approved for use by all Departments and Agencies of the Department of D

2、efense. Reactivated after 19 October 2012 and may be used for new and existing designs and acquisitions. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-7793. FIGURE 1. M7793/15-1. TERMINAL LOCATION OPTIONAL. Provided by IHSNot for Re

3、saleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7793/15A 2 REQUIREMENTS: 1. Dimensions. Dimensions and configuration shall be in accordance with figure 1. All dimensions are in inches. Unless otherwise specified, tolerances are .02 for two-place decimals and 0.015 fo

4、r three-place decimals. 2. Mounting flange. The mounting flange, threaded extension and threaded protection cap shall be constructed of aluminum alloy with an olive drab chromate coating over cadmium plating. 3. Protection cap. The protection cap shall be in accordance with MS25043-10DA per SAE-AS25

5、043 except for the finish and the means of attachment. The finish shall be in accordance with Requirement 2 and the metallic chain shall be replaced with a nylon lanyard. 4. Contacts. The contacts shall meet all the requirements of silver plated solder contacts from SAE-AS50151. PERFORMANCE REQUIREM

6、ENTS: 1. Dielectric strength. The meter shall be capable of withstanding 600 VRMS, 60 Hz (room) and 350 VRMS, 60 Hz (altitude). 2. Life accuracy. Life accuracy shall be 0.1% from -65 to +125 C and 75 to 150 VAC at 50 to 2400 Hz. 3. Power consumption. Power consumption at 115 VAC, 60 or 400 Hz, shall

7、 not exceed 50 milliwatts. 4. Operating temperature range. The temperature range shall be from -65 C to +125 C. 5. Part number. The part number is M7793/15-1. 6. Total readout. Total readout of the meters shall be 99999.99 hours. 7. Meter output. The output from the meter shall be in a serial binary

8、 coded decimal format. The output impedance shall be 100K 10%. A logical “zero” shall be between 0.0 and +0.2 volts. A logical “one” shall be between +3.3. and +6.6 volts. The output pin assignments are shown on figure 2 and the output data format is shown on figure 3. 8. Transient protection. No te

9、mporary or permanent degradation shall be produced in the meter if the input voltage should increase to 180 VRMS at 50 to 2400 Hz for a period of 150 milliseconds maximum. 9. Durability of cap and threads. No mechanical or electrical degradation after 100 cycles in accordance with SAE-AS50151. Provi

10、ded by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7793/15A 3 10. Voltage range. Operating voltage shall be from 75 to 150 VAC. 11. Durability of connectors and contacts. No mechanical or electrical degradation after 100 cycles in accordance with SAE

11、AS50151. Operational accuracy shall be checked at the end of the test. 12. Weight. Weight shall be not greater than 1.0 ounce with the attached protection cap. 13. Tensile strength of lanyard. The lanyard shall withstand a tensile load of 25 pounds when applied to Axis “A” and Axis “B” as shown on

12、figure 1. 14. Qualification tests. Qualification tests will be conducted in accordance with MIL-DTL-7793, except that the dielectric strength, voltage, temperature and accuracy shall be as specified herein. Salt spray, moisture resistance, vibration, shock, electromagnetic compatibility and low temp

13、erature storage shall be conducted with the protective cap in place. Hermetic seal test is not applicable. NOTES: 1. Elapsed time is read from the M7793/15-1 meter by mating the M7793/15-1 meters connector with the M7793/12-1 readers connector and operating the reader. 2. Digital readout and meter f

14、ace plate per MIL-DTL-7793 are not applicable since the digital readout is provided by the separate M7793/12-1 reader. 3. The meter is design to have an electrical ground and a continuous EMI/RFI shield with the threaded protection cap in place. 4. AC operation may be from either sinusoidal or squar

15、e wave sources. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7793/15A 4 FIGURE 2. Readout pin assignment. FIGURE 3. Output data format. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-D

16、TL-7793/15A 5 8. Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Referenced documents. In addition to MIL-DTL-7793, this specification sheet references SAE-AS50151 and SAE-AS25043.

17、Custodians: Preparing activity: Army - MI Navy - AS Navy - AS (Project 6645-2012-017) Air Force - 99 Review activities: Navy OS, SH DLA GS1 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • STAS 13086-1992 Glass packages Domestic jars《玻璃封装 家用广口瓶 》.pdf STAS 13086-1992 Glass packages Domestic jars《玻璃封装 家用广口瓶 》.pdf
  • STAS 13087-1992 Non-ferous ores and concentrates cyaniding lyes Determination of free and total cyanide《有色金属矿石和精矿,氰化碱冲洗 测定游离和全部氰化物 》.pdf STAS 13087-1992 Non-ferous ores and concentrates cyaniding lyes Determination of free and total cyanide《有色金属矿石和精矿,氰化碱冲洗 测定游离和全部氰化物 》.pdf
  • STAS 13088-1992 Chlorous mud Determination of gold and silver content《亚氯酸泥 测定金银含量 》.pdf STAS 13088-1992 Chlorous mud Determination of gold and silver content《亚氯酸泥 测定金银含量 》.pdf
  • STAS 13089-1992 Tool holders Threaded cyndrical shanks with axial adjustment Dimensions《工具柄 带有轴向调整的螺纹桑克斯圆柱 尺寸 》.pdf STAS 13089-1992 Tool holders Threaded cyndrical shanks with axial adjustment Dimensions《工具柄 带有轴向调整的螺纹桑克斯圆柱 尺寸 》.pdf
  • STAS 13090-1992 Building physics Heat engineerings Determination of permeability to water vapours of building materials presented as leaves or films《建筑物理学 热工学 成片状或薄膜状出现的建筑材料水蒸气渗透性的.pdf STAS 13090-1992 Building physics Heat engineerings Determination of permeability to water vapours of building materials presented as leaves or films《建筑物理学 热工学 成片状或薄膜状出现的建筑材料水蒸气渗透性的.pdf
  • STAS 13092-1992 Air Determination of strontium 89 and strontium 90 content《空气 测定锶89和锶90的含量 》.pdf STAS 13092-1992 Air Determination of strontium 89 and strontium 90 content《空气 测定锶89和锶90的含量 》.pdf
  • STAS 13093 1-1992 Precast reinforced concrete panels for the support of the underground mining works General technical quality conditions《地下采矿作业支撑所用预制钢筋混凝土板 一般质量技术条件 》.pdf STAS 13093 1-1992 Precast reinforced concrete panels for the support of the underground mining works General technical quality conditions《地下采矿作业支撑所用预制钢筋混凝土板 一般质量技术条件 》.pdf
  • STAS 13093 2-1992 Precast reinforced concrete panels for the support of the underground mining activities Shapes and dimensions《地下采矿活动支撑所用预制钢筋混凝土板 形状和尺寸 》.pdf STAS 13093 2-1992 Precast reinforced concrete panels for the support of the underground mining activities Shapes and dimensions《地下采矿活动支撑所用预制钢筋混凝土板 形状和尺寸 》.pdf
  • STAS 13094-1992 Sludges resulting from the surface waters and from the treatement of the used waters Determination of the nickel content《废水处理和地表水产生的污泥 测定镍含量 》.pdf STAS 13094-1992 Sludges resulting from the surface waters and from the treatement of the used waters Determination of the nickel content《废水处理和地表水产生的污泥 测定镍含量 》.pdf