1、AMSC N/A FSC 6645 INCH-POUND MIL-DTL-7793/15A 19 October 2012 SUPERSEDING MIL-M-7793/15 15 December 1988 DETAIL SPECIFICATION SHEET METER, TIME TOTALIZING, MINIATURE, DIGITAL, 115 VAC, 50 TO 2400 Hz, SQUARE This specification is approved for use by all Departments and Agencies of the Department of D

2、efense. Reactivated after 19 October 2012 and may be used for new and existing designs and acquisitions. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-7793. FIGURE 1. M7793/15-1. TERMINAL LOCATION OPTIONAL. Provided by IHSNot for Re

3、saleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7793/15A 2 REQUIREMENTS: 1. Dimensions. Dimensions and configuration shall be in accordance with figure 1. All dimensions are in inches. Unless otherwise specified, tolerances are .02 for two-place decimals and 0.015 fo

4、r three-place decimals. 2. Mounting flange. The mounting flange, threaded extension and threaded protection cap shall be constructed of aluminum alloy with an olive drab chromate coating over cadmium plating. 3. Protection cap. The protection cap shall be in accordance with MS25043-10DA per SAE-AS25

5、043 except for the finish and the means of attachment. The finish shall be in accordance with Requirement 2 and the metallic chain shall be replaced with a nylon lanyard. 4. Contacts. The contacts shall meet all the requirements of silver plated solder contacts from SAE-AS50151. PERFORMANCE REQUIREM

6、ENTS: 1. Dielectric strength. The meter shall be capable of withstanding 600 VRMS, 60 Hz (room) and 350 VRMS, 60 Hz (altitude). 2. Life accuracy. Life accuracy shall be 0.1% from -65 to +125 C and 75 to 150 VAC at 50 to 2400 Hz. 3. Power consumption. Power consumption at 115 VAC, 60 or 400 Hz, shall

7、 not exceed 50 milliwatts. 4. Operating temperature range. The temperature range shall be from -65 C to +125 C. 5. Part number. The part number is M7793/15-1. 6. Total readout. Total readout of the meters shall be 99999.99 hours. 7. Meter output. The output from the meter shall be in a serial binary

8、 coded decimal format. The output impedance shall be 100K 10%. A logical “zero” shall be between 0.0 and +0.2 volts. A logical “one” shall be between +3.3. and +6.6 volts. The output pin assignments are shown on figure 2 and the output data format is shown on figure 3. 8. Transient protection. No te

9、mporary or permanent degradation shall be produced in the meter if the input voltage should increase to 180 VRMS at 50 to 2400 Hz for a period of 150 milliseconds maximum. 9. Durability of cap and threads. No mechanical or electrical degradation after 100 cycles in accordance with SAE-AS50151. Provi

10、ded by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7793/15A 3 10. Voltage range. Operating voltage shall be from 75 to 150 VAC. 11. Durability of connectors and contacts. No mechanical or electrical degradation after 100 cycles in accordance with SAE

11、AS50151. Operational accuracy shall be checked at the end of the test. 12. Weight. Weight shall be not greater than 1.0 ounce with the attached protection cap. 13. Tensile strength of lanyard. The lanyard shall withstand a tensile load of 25 pounds when applied to Axis “A” and Axis “B” as shown on

12、figure 1. 14. Qualification tests. Qualification tests will be conducted in accordance with MIL-DTL-7793, except that the dielectric strength, voltage, temperature and accuracy shall be as specified herein. Salt spray, moisture resistance, vibration, shock, electromagnetic compatibility and low temp

13、erature storage shall be conducted with the protective cap in place. Hermetic seal test is not applicable. NOTES: 1. Elapsed time is read from the M7793/15-1 meter by mating the M7793/15-1 meters connector with the M7793/12-1 readers connector and operating the reader. 2. Digital readout and meter f

14、ace plate per MIL-DTL-7793 are not applicable since the digital readout is provided by the separate M7793/12-1 reader. 3. The meter is design to have an electrical ground and a continuous EMI/RFI shield with the threaded protection cap in place. 4. AC operation may be from either sinusoidal or squar

15、e wave sources. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7793/15A 4 FIGURE 2. Readout pin assignment. FIGURE 3. Output data format. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-D

16、TL-7793/15A 5 8. Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Referenced documents. In addition to MIL-DTL-7793, this specification sheet references SAE-AS50151 and SAE-AS25043.

17、Custodians: Preparing activity: Army - MI Navy - AS Navy - AS (Project 6645-2012-017) Air Force - 99 Review activities: Navy OS, SH DLA GS1 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DIN 53770-9-2007 Pigments and extenders - Determination of matter soluble in hydrochloric acid - Part 9 Cobalt content《颜料和稀释剂 溶于盐酸材料的确定 第9部分 钴含量》.pdf DIN 53770-9-2007 Pigments and extenders - Determination of matter soluble in hydrochloric acid - Part 9 Cobalt content《颜料和稀释剂 溶于盐酸材料的确定 第9部分 钴含量》.pdf
  • DIN 53771-1984 Testing of colouring materials in plastics determination of the resistance of colouring materials to sulphur dioxide《塑料中的着色剂的检验 着色剂抗二氧化硫的测定》.pdf DIN 53771-1984 Testing of colouring materials in plastics determination of the resistance of colouring materials to sulphur dioxide《塑料中的着色剂的检验 着色剂抗二氧化硫的测定》.pdf
  • DIN 53779-1979 Determination of the electric conductivity and the specific resistance (resistivity) of aqueous extracts《水溶液萃取物的导电率和电阻率的测定》.pdf DIN 53779-1979 Determination of the electric conductivity and the specific resistance (resistivity) of aqueous extracts《水溶液萃取物的导电率和电阻率的测定》.pdf
  • DIN 53780-2014 Pigments and extenders - Determination of matter soluble in water - Hexavalent chromium content《颜料和填充剂 水中溶解物质的测定 六价铬含量》.pdf DIN 53780-2014 Pigments and extenders - Determination of matter soluble in water - Hexavalent chromium content《颜料和填充剂 水中溶解物质的测定 六价铬含量》.pdf
  • DIN 53781-2016 Paints and varnishes - Methods for testing the resistance of coatings to ionizing radiation in nuclear plants《油漆和清漆 核设备涂层抗电离辐射试验方法》.pdf DIN 53781-2016 Paints and varnishes - Methods for testing the resistance of coatings to ionizing radiation in nuclear plants《油漆和清漆 核设备涂层抗电离辐射试验方法》.pdf
  • DIN 53800-1-2003 Textiles - Determination of commercial mass - Part 1 Determination of dry mass by dessication in hot air《纺织品 商业公定重量测定 第1部分 热气流干燥后测定干重》.pdf DIN 53800-1-2003 Textiles - Determination of commercial mass - Part 1 Determination of dry mass by dessication in hot air《纺织品 商业公定重量测定 第1部分 热气流干燥后测定干重》.pdf
  • DIN 53800-2-2003 Textiles - Determination of commercial mass - Part 2 Determination of commercial mass and commercial linear density《纺织品 商业公定重量测定 第2部分 商业公定重量和线性密度测定》.pdf DIN 53800-2-2003 Textiles - Determination of commercial mass - Part 2 Determination of commercial mass and commercial linear density《纺织品 商业公定重量测定 第2部分 商业公定重量和线性密度测定》.pdf
  • DIN 53803-1-1991 Sampling statistical basis one-way layout《取样 第1部分 统计学基础单向配置》.pdf DIN 53803-1-1991 Sampling statistical basis one-way layout《取样 第1部分 统计学基础单向配置》.pdf
  • DIN 53803-2-1994 Sampling practical execution《取样 实施》.pdf DIN 53803-2-1994 Sampling practical execution《取样 实施》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1