资源描述

1、MIL-1-85352 AMENDMENT 3 14 Feb 1989 SUPERSEDING MIL-1-85352 AMENDMENT 2 30 AUGUST 1987 .MILITARY SPECIFICATION INFLATOR ASSEMBLY AND GAGE ELEMENTS, PNEUMATIC PRESSURE, REMOTE CONTROL, DIRECT READING This amendment forms a part of Mil i tary Specification MIL-1-85352, dated 12 MAY 1980, and is approv

2、ed for use bv all Departments and Agencies of the Department of Defense. PAGE 1 DD Form 1426 note, change the Beneficial comments block to read as follows: Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addr

3、essed to: Naval Air Engineering Center, Systems Engineering Standardization Department (Code 531, Lakehurst, NJ 08733-5100, by using the self-addressed Standardization Document Improvement Proposal (DD Form 14263 appearing at the end of this document or by letter. Change the Federal Supply Classific

4、ation (KC) number from FSC 6685 to FSC 4920. Paragraph 2.1, delete the entire paragraph and substitute the following paragraphs: r 2.1 Government document s. * 2.1.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this specification to

5、the extent specified herein. Unless otherwise specified, the issues of these documents shall be those listed in the issue of the Department of Defense Index of Specifications and Standards (DODISS) and supplement thereto, cited in the solicitation. AMSC N/A 1 of 4 FSC 4920 DISTRIBUTION STATEMENT A.

6、Approved for pblic release; distribution is un1 imited. ,/ Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PAGE 2 Under Federal Specification, delete the following documents: “QQ-Z-325 Zinc Coating, Electrodeposited, Requirement For.“ “QQ-C-320 Chrom

7、ium Plating (Electrodeposited) .II “QQ-N-290 Nickel Plating (Electrodeposited) ,II “QQ-P-416 Plating, Cadmium (Electrodeposited) ,II PAGE 2 Under Mi 1 i tary Spec if i at ions ; Delete: “MIL-D-1000/1 Drawings Engineering and Associated Data“ and “MIL-A-8625 Anodic Coatings for Aluminum and Aluminum

8、Alloys.“ Add: “MIL-P-24074 Polytetrafluoroethylene Parts and Coatings and Polyanide Parts. PAGE 3 Under Military Standards; Add: “DOD-STD-100 Engineering Drawing Practices.“ Paragraph 2.2, Under American National Standard Institute, delete: “ANSI-B40.1-1974 Gages, Pressure and Vacuum, Indicating Typ

9、e, Elastic Element“ . and substitute “ANSI-B40.1 Gages, Pressure Indicating Dial Type, Elastic Element .II “ - (Copies of the above publication may be obtained from the American National Standards Institute, 1430 Broadway, New York, NY 10018). PAGE 10 Paragraph 3.8.2.2, add at the end of sentence: “

10、The petcock shall be installed such that the vented gases are directed down or away or both from the operator. I Paragraph connects that perm faci 1 i tat Paragraph to the remote controller body shall include a swivel lits the hose to easily and continuously rotate 360, ing the winding of the hose f

11、or storage in the carry 3.8.3, change the last sentence to read: “The end of the hose that . type fitting thus i ng case. II PAGE 12 3.8.3.1, delete the entire paragraph and substitute 2 the fol lowing: Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,

12、-MIL-1-85352 AMENDMENT 3 PAGE 12 3.8.3,l Tire valve adapter. The tire valve adapter shall be fabricated of stainless steel in accordance with Figure 2. One end shall be threaded to fit a tire valve stem and contain a compressi.on resistant gasket to create an air tight seal. The gasket shall be fabr

13、icated of Polytetrafluoroethylene (PTFE) in accordance with MIL-P-24074 (Ships), Type 1, grade B, 25% glass filled. The other end shall be fitted with a replaceable tire valve adapter extension. No special tools shall be required for attaching the adapter to the tire valve stem.“ * 3.8.3.2 Xl-vice h

14、ose assembly. Add after the last sentence: “The end of the hose that connects to the remote controller body shall include a swivel type fitting that permits the hose to easily and continuously rotate 360 degrees, thus facilitating the winding of the hose for storage in the carrying case. I Paragraph

15、 3.8.5, change to read the last sentence: “The carrying case shall be fini shed in accordance with MIL-STD-808, II “_ PAGE 18 Paragraph 3.10, line 4, delete: “MIL-D-1000/ Chapter 600. II Paragraph 3.11, change last sentence to read: in accordance wi th MIL-STD-808, I 1 II and subs t i tute “DOD-STD-

16、 “Protective finishes shall 1 O0 be PAGE 22 Paragraph 4.6.2, 1 ine 15, delete: “ANSI-B40.1-1974“ and substi tute “ANSI-B40.1 II * Paragraph 4.6.2, change the last sentence to read: “It shall have a pressure range of not more than 3000 psi, and shall be graduated in increments not larger than 30 psig

17、.“ PAGE 27 Paragraph 6.2.f(l), line 3, delete: “Attn: Code 92713“ and substitute “Attn: Code 52621 ,II 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-AMENDMENT 3 PAGE 27 Paragraph 6.2.f(2), line 3, delete: “Attn: Code AIR-534“ and substitute “Attn

18、: Code AIR-552.“ Paragraph 6.2.f(2, line 5, delete: “Attn: Code 92713“ and substitute “Attn: Code 52621 .II PAGE 28 Paragraph 6.3, at the end of the last sentence, delete: “Attn: Code 92713“ and substitute “Attn: Code 52621 .II Add the following paragraphs to section 6: 6.4 Subject term (key words)

19、listing. a. Inflator Pneumatic b. Remote controlled inflation. c. Dual ChlJck Stem Gages. d. Operating Pressure 600 psi (maximum) e. Aircraft Tire. 6.5 The margins of this amendment are marked with an asterisk to indicate where changes (additions, modifications, corrections, deletions) from the prev

20、ious amendment were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irreipective of the marginal notations and relationship to the last previous amendment. Custodians: Air Force - 99 Navy - AS Army - AV Preparing activity: Navy - AS (Project No. 4920-0453) Review activity: DLA-GS 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-