1、MIL-PRF-85045/15B 16 September 1999 SUPERSEDING MIL-C-85045/15A 26 May 1995 PERFORMANCE SPECIFICATION SHEET CABLE, FIBER OPTIC, FOUR FIBERS, CABLE CONFIGURATION TYPE 2 (OFCC), APPLICATION B (SHIPBOARD), CABLE CLASS SM AND MM, (METRIC) This specification is approved for use by all Departments and Age
2、ncies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification and MIL-PRF-85045. CLASSIFICATION: Fiber optic cable configuration type: 2 (OFCC). Fiber cable class: MM (graded-index, glass core and glass cladding, multimode) SM (di
3、spersion-unshifted, glass core and glass cladding, single-mode) DESIGN AND CONSTRUCTION: Fiber: Class MM fibers shall be in accordance with MIL-PRF-49291/6. Class SM fibers shall be in accordance with MIL-PRF-49291/7. Buffer diameter: 900 I 50 pm. OFCC : Dimensions and configuration: See figure 1. J
4、ACKE FIBER- NOTE : T- STRENGTH MEMBERS r BUFFER 1.8 min 2.2 min 1. Dimensions are in millimeters. FIGURE 1. Optical fiber cable component. AMSC N/A 1 of 5 FSC 6015 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networ
5、king permitted without license from IHS-,-,-Mass per unit length: 5 15 kg/km. Short term minimum bend diameter: Eight times the OFCC outer diameter Long term minimum bend diameter: Sixteen times the OFCC outer diameter. Tensile loading: 2 270 N. Dynamic bend tensile load: 90 N minimum. Jacket materi
6、al: The OFCC jacket shall be composed of a low halogen, low smoke, low toxicity polymer material. FINISHED CABLE : Dimensions and configuration: See figure 2. Four OFCC units shall be helically laid over the central member. The minimum outer jacket thickness shall be not less than 0.7 mm (establishe
7、s compatibility with termination and penetration devices). CABLE JACKET CENTRAL MEMBER 7.75 mm . 8.5 mm NOTES : 1. OFCC - Optical fiber cable component 2. Dimensions are in millimeters. OFCC SEE NOTE 11 WATERBLOCKING OR FILLER MATERIAL AND STRENGTH MEMBERS - FIGURE 2. Four OFCC fiber optic cable Num
8、ber of fibers: 4 (one per OFCC) . Concentricity: 2 0.8 Jacket material: The overall jacket shall be composed of a low halogen, low smoke, low toxicity polymer material. Mass per unit length: 5 100.0 kg/km Short term minimum bend diameter: Eight times the cable outer diameter. (The short term minimum
9、 bend diameter is to be used in all environmental and mechanical tests which specify a cable minimum bend diameter.) Long term minimum bend diameter: Sixteen times the cable outer diameter. L Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Minimum co
10、ntinuous length: The minimum continuous length of all cables shall be not less than 0.5 km. If lengths less than 0.5 km are specified in the purchase order, Quality Conformance Inspection shall be performed on test specimens not less than 0.5 km in length from which the purchase order lengths are cu
11、t. PERFORMANCE REQUIREMENTS: Optical properties: Maximum attenuation rate: 4.5 dB/km at 850 I 20 nm, 2.0 dB/km at 1300 I 20 nm for class MM fiber. 1.0 dB/km at 1310 I 20 nm and 1550 I 20 nm for class SM fiber. Bandwidth: Fiber with a minimum bandwidth of 500 Mhz-km at 1300 nm shall be used (multimod
12、e cables only). Bandwidth is not specified at 850 nm. Change in optical transmittance: Measurements to be made at 1300 I 20 nm Crosstalk: Applicable. Mechanical properties: Tensile loading and elongation: Applicable, tensile loading 2 1875 N Operating tensile loading: Applicable. Cyclic flexing: 500
13、 cycles at 25OC I 2OC and 100 cycles at -28OC I 2OC. Change in optical transmittance measurements are to be made every 100 cycles for the 500 cycle exposure and every 25 cycles for the 100 cycle exposure. Each change in optical transmittance measurement shall be performed with the test specimen in t
14、he same position in the test cycle. The cycling may be halted to perform the change in optical transmittance measurement. Crush: Applicable Cable twist bending: 500 cycles at 25OC I 2OC and 100 cycles at -28OC I 2OC. Change in optical transmittance measurements are to be made every 100 cycles for th
15、e 500 cycle exposure and every 25 cycles for the 100 cycle exposure. Each change in optical transmittance measurement shall be performed with the test specimen in the same position in the test cycle. The cycling may be halted to perform the change in optical transmittance measurement. Radial compres
16、sion: Applicable. Impact: 50 cycles at 25OC I 2OC and 20 cycles at -4OOC I 2OC. Hosing: Both low pressure and hydrostatic pressure are applicable Hydrostatic: 7.7 MPa for M85045/15-01P and M85045/15-02P. Dripping: Applicable. Environmental: Temperature range: Operating: -28OC to 65OC. Nonoperating:
17、-4OOC to 7OoC. Storage: -4OOC to 7OoC. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PIN M85045/15-01P M85045/15- 02P 4 Superseding M85045/15-01 M85045/15-01N M85045/15-01T M85045/15-02 M85045/15-02N M85045/15-02T Provided by IHSNot for ResaleNo
18、reproduction or networking permitted without license from IHS-,-,-Qualification by similarity: Manufacturers who produce products for MIL-PRF-85045/13 and products for this specification sheet, and are qualified under MIL-PRF-85045/13 and pass the attenuation rate, low temperature flexibility (cold
19、bend), impact, low pressure hosing, abrasion, smoke generation and flame propagation, flame extinguishing, and size inspection specified herein, are qualified under this specification sheet. Testing may be performed on a single length of cable, with a minimum length of 0.5 km. Manufacturers who prod
20、uce products for MIL-PRF-85045/18 and products for this specification sheet and are qualified under MIL-PRF-85045/18 and pass the attenuation rate, low temperature flexibility (cold bend), impact (low temperature only), low pressure hosing, cable abrasion resistance, smoke generation and flame propa
21、gation, flame extinguishing, cable jacket material tensile strength and elongation, durability of identification, size, cable life (both jacket material and complete cable), cyclic flexing, electromagnetic effects, dripping, weathering, fluid immersion, paint susceptibility, acid gas generation, hal
22、ogen content, toxicity index, and fungus inspections specified herein, are qualified under this specification sheet. This qualification by similarity is applicable if the only difference between the previously qualified MIL-PRF-85045/18 cable and this MIL- PRF-85045/15 cable is the outer jacket mate
23、rial. If the MIL-PRF-85045/15 cable is identical to the previously qualified MIL-PRF-85045/18 cable, no testing is required for qualification. A certificate of compliance may be submitted in lieu of performing the acid generation, halogen content, toxicity index and fungus inspections. Testing may b
24、e performed on a single length of cable, with a minimum length of 0.5 km. Manufacturers who are qualified under this specification sheet for multimode fiber cable and whose single-mode fiber cable passes the visual and mechanical, attenuation rate, temperature cycling, humidity, storage temperature,
25、 cyclic flexing, crush, cable twist-bending, impact (low temperature only), tensile loading and elongation, operating tensile loading, thermal shock and dynamic bend inspections specified herein, are qualified under this specification sheet for single mode fiber cable. This qualification by similari
26、ty is applicable if the only difference between the previously qualified cable and the cable under test is that the optical fiber has been changed from a multimode fiber to a single-mode fiber. Testing may be performed on either one or two lengths of cable, each with a minimum length of 0.5 km. Test
27、 order must be observed up to and including the storage temperature test. If only one cable length is used the thermal shock test shall be performed after the storage temperature test. Manufacturers who are qualified under MIL-PRF-85045/13 for both multimode and single mode fiber cable and under thi
28、s specification sheet for multimode fiber cable are qualified under this specification sheet for single mode fiber cable. Manufacturers who are qualified under MIL-PRF-85045/13 for both multimode and single-mode fiber cable and under this specification sheet for multimode fiber cable are qualified u
29、nder this specification sheet for single-mode fiber cable Custodians: Army - CR Navy - SH Air Force - 11 NASA - NA Preparing activity: Navy - SH Agent : DLA - CC Review activities: Army - AR, AV, MI Navy - EC, YD Air Force - 02, 19, 80, 99 DLA - CC (Project 6015-0034-03) 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-