NAVY MIL-STD-1320-157-1974 TRUCKLOADING OF HAZARDOUS MATERIALS CHARGE PROPELLING 6 INCH 47 DOMESTIC UNIT LOAD《 6 INCH 47危险原料装车收费》.pdf

上传人:eveningprove235 文档编号:981867 上传时间:2019-03-12 格式:PDF 页数:5 大小:199.29KB
下载 相关 举报
NAVY MIL-STD-1320-157-1974 TRUCKLOADING OF HAZARDOUS MATERIALS CHARGE PROPELLING 6 INCH 47 DOMESTIC UNIT LOAD《 6 INCH 47危险原料装车收费》.pdf_第1页
第1页 / 共5页
NAVY MIL-STD-1320-157-1974 TRUCKLOADING OF HAZARDOUS MATERIALS CHARGE PROPELLING 6 INCH 47 DOMESTIC UNIT LOAD《 6 INCH 47危险原料装车收费》.pdf_第2页
第2页 / 共5页
NAVY MIL-STD-1320-157-1974 TRUCKLOADING OF HAZARDOUS MATERIALS CHARGE PROPELLING 6 INCH 47 DOMESTIC UNIT LOAD《 6 INCH 47危险原料装车收费》.pdf_第3页
第3页 / 共5页
NAVY MIL-STD-1320-157-1974 TRUCKLOADING OF HAZARDOUS MATERIALS CHARGE PROPELLING 6 INCH 47 DOMESTIC UNIT LOAD《 6 INCH 47危险原料装车收费》.pdf_第4页
第4页 / 共5页
NAVY MIL-STD-1320-157-1974 TRUCKLOADING OF HAZARDOUS MATERIALS CHARGE PROPELLING 6 INCH 47 DOMESTIC UNIT LOAD《 6 INCH 47危险原料装车收费》.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、i SIGNATURE lE NAILS, FF-N-105, TYPE Il, STYLE 10, COMMON BRIGHT; STRAPPING, QQ-S-781, TYPE I, CLASS A, PLYWOOD, COMMERCIAL STANDARD, CS45, GRADE INTERIOR C-D. FOR GENERAL TRUCKLOADING PROCEDURES REFER TO THE GENERAL TRUCKLOADING DOCUMENT, MIL-STD-13 (NAVY). 6. 7. 8. FTL 40,- AND 44 FT TRAILER ( VAN

2、) I. WHEN 44 FT OR 45 FT VANS ARE USED FOR FTL OF 24 UNIT LOADS, IT IS NOT NECESSARY TO DOUBLE TIER OR UNITIZE. USE.DOUBLE ROW PATTERN AND BLOCK AND BRACE IN SAME MANNER AS FOR THE 40 FT TRAILER. WHEN A 40 FT VAN IS USED; LOAD, BLOCK AND BRACE AS SHOWN ON PAGE 3. 2. DETAIL REM OLOCKING ASSEMBLY 1 RE

3、QUIRED YE GEMML NOTI 3 FRONT BULK:NAD 1 MQUIIED PAGE 2 ,t* Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-1320 -L57 81 777771L 007OY40 7 II PLYWOOD 40 1/2x45 i/2x 1/2 10 STAPLE FOR I 1/4STRAP SEAL FOR l 1/4 STRAP MILSTD-1320-157 (NAVY) 2 32

4、8 SEE UNITIZING DETAIL PAGE ! I - I- TRUCKLOAD DATA WEIGHT (APPROX) . 40,440 LBS NUMBER OF UNIT LOADS . 24 1 l/4 x .O35 x 25 FT 8 STRAP 4 1 AFT CROSiMEMBER 2 x 6 x W*-l 3 2 3PERJOINT 12d NO.PCS NAIL I ”“ SIZE REQD TO NAILS IECE NO DESCRIPTION SECTION C-C US1 OF MATERIALS AND NAILING DATA FTL 40 FT T

5、RAILER (VAN ) PAGE 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-1320-157 (NAVY) 21 LTL 40 FT TRAILER (VAN) 111 11111111 11 11111I11 1. WHEN REQUIRED TO SHIP LESS-THAN-TRUCKLOAD, SELECT THE CORRECT LOAD PATTERN FOR THE NUMBER OF UNIT LOAD

6、S TO BE SHIPPED FROM TABLE 1. TABLE I 1211 1111 III NO. OF UNIT LOAD PATTERN* FWD LOADS h I111 i111 111 22 III1 1111 111 I111 1111 111 NO. OF LOADS UNIT LOAD PATTERN* FWD 11 11 20 11111111 111Il111 *LOAD PATTERN SHOWS FLOOR PLAN FOR TRAILER. NUMBER IN BLOCKS INDICATES NUMBER OF UNIT LOADS IN LAYER.

7、2. WHEN REQUIRED TO SHIP 23 UNIT LOADS USE LOAD PATTERN SHOWN IN TABLE I. BLOCK AND BRACE LOAD AS SHOWN FOR FTL ON PAGE 3. THE SINGLE TWO HIGH STACK OF UNIT LOADS SHALL HAVE TWO ADDITIONAL STRAPS TO PREVENT LATERAL MOVEMENT AS SHOWN IN THE UNITIZING DETAIL, PAGE 5. WHEN REQUIRED TO SHIP 22 UNIT LOAD

8、S USE LOAD PATTERN SHOWN IN TABLE i. BLOCK AND BRACE LOAD AS SHOWN FOR FTL ON PAGE 3. WHEN REQUIRED TO SHIP 21 UNIT LOADS USE LOAD PATTERN SHOWN IN TABLE I. BLOCK AND BRACE LOAD AS SHOWN FOR FTL ON PAGE 3, AND ADD 2 KNEE BRACES (DETAIL O), 1 EACH AGAINST WOODEN FRAME OF UNIT LOAD. WHEN REQUIRED TO S

9、HIP 20 UNIT LOADS USE LOAD PATTERN SHOWN IN TABLE I. USE FRONT BULKHEAD AS SHOWN IN FTL PAGE 3 AND WO KNEE BRACES, DETAIL D, PER ROW (4 PER TRAILER), I EACH AGAINST WOODEN FRAME OF UNIT LOAD. WHEN REQUIRED TO SHIP 19 OR LESS UNIT LOADS, USE DOUBLE ROW P4TTERN. BLOCK AND BRACE AS FOR 20 LOADS. ACTUAL

10、 SHIPPING REQUIREMENTS DETERMINE THE NUMBER OF UNIT LOADS TO BE SHIPPED. THE LOAD PATTERN AND DUNNAGING SHALL BE IN ACCORDANCE WITH THE APPROPRIATE PARTS OF THIS DOCUMENT AND THE GENERAL TRUCKLOADING STANDARD, MIL-STD-1320 (NAVY). 3. 4. 5. 6. 7. TRAILER FLOOR DETAIL 0 KNEE BRACE 2 REQUIRED PER ROW (

11、4 REQUIRED PER WUBLE ROW) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-1320 -157 1 77777LL O070442 2 D MILSTD-1320-157 (NAVY) UNITIZING PROCEDURE I. 2. WHEN REQUIRED BY THE FTL OR LTL REQUIREMENTS OF THIS MIL-STD, THE WO HIGH STACKED UNIT

12、LOADS SHALL BE STRAPPED AS SHOWN, THE 2 x 6 DOUBLED STIFFENER SHALL EXTEND FROM THE TOP OF STACKED UNIT LOADS TO THE TOP OF THE PALLET OF THE BOTTOM UNIT LOAD. THE STIFFENER SHALL BE LAMINATED WITH FOUR 10d NAILS TP PREVENT SHIFTIVG. THE 1 1/4 INCH STEEL STRAPS POSITIONED AS SHOWN ENCIRCLE THE STACK

13、ED UNIT LOADS AND PASS UNDER THE DECK OF THE BOTTOM PALLET WITH THE STRAPS HOLDING THE STIFFENERS IN PLACE. TENSION STRAPS AND SEAL WITH WO DOUBLED CRIMPED SEALS. SECURE EACH STRAP TO THE STIFFENER WITH FOUR 1 i/4 INCH STAPLES. 3. 4. 2 x 6 DOUBLED STIFFENER LAM (BOTH ENDS) SEE GENERAL NOTE 4 1 1/4 x

14、 .O35 STEEL PAGE 2 2 REQUIRED ONLY SHIPPING 23 UNI1 SEE LTL NOTE 2 STRAP WHEN LOADS. REVIEW ACTIVITIES: PREPARING ACTIVITY: NAVY - OS, AS NAVY -as (PROJECT NO. 8140-Nm) PAGE 5 MJ.S. GOVERNMENT PRINTING OFFICE : 1974-803-110/20?3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1